Web Analytics Made Easy - StatCounter

Booster Station Repair Tenders

Get complete information related to latest Booster Station Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Booster Station Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Booster Station Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43760807 Due date: 18 Feb, 202618 Feb, 2026 NA
Tender For supply of procurement of avcat system for 05 x fss : - 1. 0 avcat pump and filtration module , 1. 1 onboard spares , 1. 2 documentation , 1. 3 special tools, consumables etc , 1. 4 class inspection charges bidder to quote ls cost per shipset , 1. 5 service engineer charges bidder to quote ls cost per shipset , 1. 6 training charges bidder to quote ls cost per shipset , 1. 7 extended warranty bidder to quote ls cost for one year per shipset , 1. 8 depreservation and represervation charges as per tts , 2. 0 avcat dispensing module with hifr , 2. 1 onboard spares , 2. 2 documentation , 2. 3 special tools, consumables etc , 2. 4 class inspection charges bidder to quote ls cost per shipset , 2. 5 service engineer charges bidder to quote ls cost per shipset , 2. 6 training charges bidder to quote ls cost per shipset , 2. 7 extended warranty bidder to quote ls cost for one year per shipset , 2. 8 depreservation and represervation charges as per tts

State Government

CTN :43759044 Due date: 04 Feb, 202604 Feb, 2026 1.50 Lacs
Tender For installation of cold drinking water with filtration chamber, pump , platform and water storage tank at joynagar primary school under dakshinpara-ii g.p.

State Government

CTN :43759071 Due date: 04 Feb, 202604 Feb, 2026 1.50 Lacs
Tender For installation of cold drinking water with filtration chamber, pump , platform and water storage tank at natungram primary school under dakshinpara-ii g.p

State Government

CTN :43759100 Due date: 04 Feb, 202604 Feb, 2026 1.50 Lacs
Tender For installation of cold drinking water with filtration chamber, pump , platform and water storage tank at probhatnagar primary school under dakshinpara-ii g.p

Central Government/Public Sector

CTN :43553282 Due date: 04 Feb, 202604 Feb, 2026 NA
Tender For repair and maintenance of swimming pool installation and connected items including chemical for swimming pool and repair and maintenance of cl, dl, gl pipe line with connected accessories water supply pump sets, bore well, water filtration plants, ch

Central Government/Public Sector

CTN :43553290 Due date: 04 Feb, 202604 Feb, 2026 NA
Tender For repair and maintenance of pump sets, control panels, water filtration plants, water pipes line gate and sluice valve and associated works at 8.0 hect land at icgs dahanu

State Government

CTN :43594334 Due date: 04 Feb, 202604 Feb, 2026 NA
Tender For empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20

CTN :43738200 Due date: 05 Feb, 202605 Feb, 2026 16.25 Crore
Tender For site development, indoor stadium, sump and pump room, borewell, substation civil works, swimming pool, septic tank - 50 - 100 users, electrification - indoor stadium, substation, swimming pool, flood lighting, street lighting, filtration firefigh

State Government

CTN :43583955 Due date: 04 Feb, 202604 Feb, 2026 96.34 Lacs
Tender For construction of pump and filtration house with underground reservoir for olympic standard swimming pool at narayantala depomath within ward no.17 under bidhannagar municipal corporation. (15th finance)

CTN :43449836 Due date: 03 Feb, 202603 Feb, 2026 NA
Tender For construction of goods circulating area, pp shed at khongsang station and repair to approach road, provision of water supply to station building, platforms and staff quarter at vangaichungpao station, kambiron station and thingou station, including provision of pump house, filtration unit as per scheme, repair and maintenance of rest house and site camp office, security barrack and roads for security camps including other ancillary works at jrbm, rgbp and tgbp under dy.ce/con/jrbm at scl in connection with the construction of new bg railway line project from jiribam to tupul (imphal)
 Loading, Please wait...

Connect us via What's Up