Get complete information related to latest Bus Bar Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bus Bar Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bus Bar Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39574756 Due date: 26 Mar, 202526 Mar, 2025 2.00 Crore
Tender For supply of telescopic channel made of mild steel 1point 25mm thick of 45kg capacity , supply only on load change over switch front operated switch disconector with extenderd shaft and ip 65 fp 400 amps 36 ka , supply only 3 phase automatic phase sequence corrector of 50 amp load capacity complete make abb , supply only 3 phase automatic phase sequence corrector of 20 amp load capacity complete make abb , xlpe cable alum conductor 3 core 300 sqmm 33 kv , 33 kv e 3 core 300sqmm standard aluminium conductor xlpe armoured cable , solar inverter 100kw , solar inverter 50kw , solar inverter 33kw , solar inverter 20kw , supply hi wall split air condition units in stone walls type split ac inverter model 5 star rating adheriing to specified bee 100 percent copper tubing and of capacity 2 point 0 tr , supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed input vairiation between 170v to 250v , refrigerators 310ltr doble door , led kerb stone of size 500mm x 150mm x 200mm made out of 5 foundation rods ensuring complete protection against theft and having a led strip of length 470mm with 22 nos led duly plastic coated of any , gaseous type gravity feed chlorinator of capacity upto 2 kg hrs chemical grade panel board 6mm thick 2 x 4 feet pvc primary filter safety gauge teflon pipe 5 rm ubend secondary filter , new empty chlorine gas cylinder 100kgs capacity along with all accessories , chlorine cylinder emergency safety kit on operating cylinders consist of following accessories cylinder valve hood assembly 01 set cylider valve cap with silver coating valve 01 set , self contained open circuit breathing apparatus with oxygen cylinderfor duration of 30 minutes with audio alarm system light weight fiber glass back plate and two stage pressure reducing , upvc pipes sch 40 with fittings onwalls ceiling or laying in floors of size 25mm complete all as specified and directed by engineer in charge , gaseous type gravity feed chlorinator of capacity upto 2 kg hrs chemical grade panel board 6mm thick 2 feet x 4 feet mounted consist of flow meter , new empty chlorine gas cylinder 100kgs capacity alongwith all accessories , self contained open circuit breathing apparatus with oxygen cylinder for duration of 30 minutes with audio alarm system light weight fiber glass back plate and two stage pressure reducing sys , solar street light 40 watt made with high efficiency monocrystalline with minimum 150wp , steel tublar high mast pole 12 point 5 meter height octagonal material heavy duty mild steel surface along with base , eros decorative orbit s round arm for fixing inverted post top lamps made from casting , pole for fixing iverted post top lamps made from castrion from casting procedure decorative having 3 different dia in one length , epr ethylene propylene rubber pcp high mast cable multistranded copper cable 4 sqmm 4 core , sintex box for street light pole size 205mm x 200mm x 105mm along with aluminium busbar 100 amps , galavinised iron steel water tubing 50mm nominal bore heavy grade , numerical based overcurrent and earth fault protection relay of having 08 nos led indictor for showing different ype of signals operating on vx 24 25 vdc 40 240 vac , precast manhole cover 1 point 20 x 0 point 60m x 0 point 06m , precast manhole cover 1 point 90 x 0 point 60m x 0 point 06m , precast manhole cover 1 point 90 x 0 point 45m x 0 point 075m , fencing of size 75 x 75 x 3 point 15 mm dia , bid details/ 2 / 61 submersible pump 5 hp 3 phase , submersible pump 3 hp 3 phase , submersible pump 2 hp 3 phase , submersible pump 1 hp single phase , sumersible pump half hp single phase , dol starter for 1 hp motor , dol starter for half hp motor , dol starter for 2 hp motor , dol starter for 3 hp motor , automatic star delta starter 3 phase 5 hp , automatic star delta starter 3 phase 20 hp , gi tubing med grade 40mm dia , gi tubing med grade 50mm dia , pop up sprinkler , heavy duty pvc pipe 63mm dia , h

Central Government And Public Sector

CTN :39112820 Due date: 05 Mar, 202505 Mar, 2025 NA
Tender For corrigendum : supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole load break switch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminal blocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpm meter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpm meter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.
 Loading, Please wait...

Connect us via What's Up