Get complete information related to latest Cable Jointing Kit Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Jointing Kit Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Jointing Kit Tenders.
Tender For supply of taking down carefully copper aluminium point wiring,material labour for point wiring for light fan bell,supply and fixing in replacement 36 watts recess pendant,supply and fixing switch modular piano flush button single pole,supply and fixing led tube light fitting 18 oblique 20 watt,taking out unserviceable service wire,supply and fixing 12 watts led bulb,supply and fixing 9 watt led wall light ceiling light,supply and fixing of powder coated pressure die cast,supply and fixing amp rating 240v 10ka c curve,supply and fixing amp rating 240v, 10ka c curve sp miniature,earthing complete with copper,supply and fixing fixed in repairs,supply laying testing and commissioning ug cable xlpe,supply and fix triple pole gand operated device,material and labour for cablejointingkit end joint,refixing of card various of stabilizer
Tender For corrigendum : maintenance- repairs- replacement of electrical items for various projects executed under srinagar smart city limited for a period of 2 years. - supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage, delivery and erection of following sizes of distribution transformer at site., i) 630 kva distribution transformer, ii) 400 kva distribution transformer, iii) 250 kva distribution transformer, iv) 100 kva distribution transformer, v) 63 kva distribution transformer, fixing of fabricated gi angle/channel/flat/pole collars., fixing of galvanised nuts and bolts., supply, installation, testing, commissioning, insurance, unloading, carriage and delivery at site, laying, stringing and binding of conductor including joints with pg clamps of required following size of acsr conductor (0.1 /0.05/ 0.03), i) 100 sqmm acsr (dog), ii) 50 sqmm acsr (rabbit), iii) 30 sqmm acsr (weasel), supply, installation, testing, commissioning of ab (ht) cable of following sizes:, iii) 50 mm ab (ht) cable (3x50+1x70 mm ) xlpe(11 kv, 3c +earth), iv) 70 mm ab (ht) cable (3x70+1x95 mm ) xlpe(11 kv, 3c +earth), v) 95 mm ab (ht) cable (3x95+1x95 mm ) xlpe(11 kv, 3c +earth), vi) 120 mm ab (ht) cable (3x120+1x95 mm ) xlpe(11 kv, 3c +earth), mid span straight through jointingkit for 11 kv abc of following sizes:, i) 11 kv abc 50-95mm straight through jointingkit (3 core), ii) 11 kv abc 120-185mm straight through jointingkit (3 core), iii) 11 kv abc 240-300mm straight through jointingkit (3 core), heat shrinkable outdoor cable termination kit for ht/lt abc of following sizes:, i) 11 kv abc 70-95 mm outdoor cable termination kit, ii) 11 kv abc 120 mm outdoor cable termination kit, iii) 11 kv abc 150-185 mm outdoor cable termination kit, iv) 11 kv abc 240-300 mm outdoor cable termination kit, supply, installation, testing, commissioning of ab (lt) cable of following sizes:, ii) 50 mm ab (lt) cable ( 3x50 + 1 x 16 + 1 x 35) mm xlpe (1.1kv, 3+1 c, al), iii) 70 mm ab (lt) cable (3 x 70 + 1 x 16 + 1 x 50) mm xlpe (1.1kv, 3+1 c, al), iv) 120 mm ab (lt) cable (3 x 120 + 1 x 25 + 1 x 95) mm xlpe (1.1kv, 3+1 c, al), straight through cablejointingkit for lt abc of following sizes:, ii) 50 mm ab (lt)straight through cablejointingkit, iii) 70 mm ab (lt)straight through cablejointingkit, iii) 120 mm ab (lt)straight through cablejointingkit, dismantling, i) dismantling, stacking of 9/8 mtr st poles and transportation back to divisional store as per the instruction of electrical incharge., ii) dismantling of 0.03/0.05/0.1 acsr conductor and transportation to divisional stores (servicible), servo voltage stabilizer, i) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 63 kva, 3-phase oil cooled servo (complete job), ii) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 50 kva, 3-phase oil cooled servo (complete job), rmu, supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 4 way type,two isolators and two circuit breakers 11 kv, ring main unit ,sf6 insulated, out-door type, extensible type,breaking capacity 25 ka for one second with sf6 circuit breaker / vcb self powered with o/c + e/f relay comprising of a) 11kv 630 amp motorised isolator including earthing switches with making capacity 52ka, having mechanical on/off, earth indications with fault current indicator.b) 11kv ,400 amp motorised spring operated, circuit breakers with earthing switches, connecting the rmu to supply transformer. c). copper bus bar of 630 amp rating.d). 1 no numerical aux. powered relay having non directional o/c and e/f protection (for each ciruit breaker).d). the circuit breaker enclosures shall be outfitted with a communicable-type numer
Tender For bid to ras corrigendum : tender for supply of cablejointingkits e e - jkit st h s 11kv 1c 150mm2 al , jkit st h s xlpe 11kv 1c 300mm2 al , jkit st h s 6point 6kv 1c 150mm2 al , jkit st h s 6point 6kv 1c 300mm2 al , jkit st h s 6point 6kv 3c 150mm2 al , jkit st h s xlpe 6point 6kv 3c 185mm2 al , jkit st h s 6point 6kv 3c 240mm2 al , jkit st h s xlpe 3point 3kv 1c 300mm2 al , jkit st h s xlpe 1point 1kv 1c 150mm2 al , jkit st h s xlpe 1point 1kv 1c 240mm2 al , jkit st h s xlpe 1point 1kv 1c 300mm2 al , jkit st h s 1point 1kv 1c 630mm2 al , jnt ter kit str through frls xlpe 1point 1kv , jkit st h s 1point 1kv 2c 2point 5mm2 cu , jkit st h s xlpe 1point 1kv 2c 6mm2 al , jkit st h s xlpe 1point 1kv 2c 16mm2 al , jkit st h s xlpe 1point 1kv 2c 35mm2 al , jkit st h s pvc 1point 1kv 2c 70mm2 al , jkit st h s xlpe 1point 1kv 2c 120mm2 al , jnt ter kit str through 1point 1kv 3c 1point 5mm2 , jkit st h s 1point 1kv 3c 2point 5mm2 cu , jkit st h s pvc 1point 1kv 3c 6mm2 al , jkit st h s 1point 1kv 3c 16mm2 al , jkit st h s 1point 1kv 3c 25mm2 al , jkit st h s pvc 1point 1kv 3c 35mm2 al , jkit st h s 1point 1kv 3c 50mm2 al , jkit st h s 1point 1kv 3c 70mm2 al , jkit st h s 1point 1kv 3c 95mm2 al , jkit st h s 1point 1kv 3c 120mm2 al , jkit st h s 1point 1kv 3c 150mm2 al , jkit st h s xlpe 1point 1kv 3c 240mm2 al , jkit st c s 1point 1kv 3point 5c 50mm2 al , jkit st h s pvc xlpe 1point 1kv 3point 5c 70mm2 al , jkit st c s 1point 1kv 3point 5c 120mm2 al , jkit st h s 1point 1kv 3point 5c 300mm2 al , jkit st h s 1point 1kv 4c 6mm2 al , jkit st h s pvc 1point 1kv 4c 16mm2 al , jkit st h s 1point 1kv 5c 1point 5mm2 cu , jkit st h s pvc xlpe 1point 1kv 7c 1point 5mm2 cu , jkit et h s 11kv 1c 150mm2 al , jkit et h s xlpe 11kv 1c 300mm2 al , jkit et h s xlpe 6point 6kv 1c 150mm2 al , jkit et h s xlpe 6point 6kv 1c 300mm2 al , jkit et h s xlpe 3point 3kv 1c 300mm2 al , jkit st h s 6point 6kv 1c 400mm2 al , jkit st h s xlpe 11kv 3c 240mm2 al , jkit et h s xlpe 11kv 3c 240mm2 al , jkit et h s xlpe 132kv 1c 630mm2 cu , heat shrink sleeve 4 16mm 1point 1kv cable , heat shrink sleeve 1point 1kv , heat shrink sleeve 8 28mm 1point 1kv cable , heat shrink sleeve 28 35mm 1point 1kv cable , jkit st h s 1point 1kv 3point 5c 35mm2 al , jkit st c s 1point 1kv 3point 5c 95mm2 al , jkit st h s pvc 1point 1kv 10c 1point 5mm2 cu , jkit et e m 6point 6kv 3c 150mm2 al , jkit st h s 1point 1kv 3point 5c 120mm2 al , jnt ter kit fl cu 6point 6kv 3cx25 3cx16 3 , jnt ter kit end fl cu 6point 6kv , jnt ter kit fl cu 19cx2point 5 8px1point 5sqmm , jnt ter kit hs str thru 3cx185 3cx70 3 , jnt ter kit trailing 1point 1kv 12c 2point 5mm2 , jnt ter kit hs str thr 1point 1kv , jnt ter kit hs str thru 1point 1kv , jkit st h s epr 1point 1kv 4c 4mm2 cu , jkit st h s pvc 1point 1kv 4c 2point 5mm2 cu
Tender For corrigendum : estimate for repl. of 150 mtr length 11 kv ug cable 3x300 sqmm, 02 no cablejointingkit installed at 11kv ttc dl feeder, at national highway underground crossing near gadariyanala village bansapur under budni
Tender For corrigendum : estimate for repl. of 150 mtr length 33 kv ug cable 3x300 sqmm, 02 no cablejointingkit installed at 33kv mana feeder, at railwayline underground crossing near 33/11kv substation village budni
Tender For corrigendum : the work of shifting of line full deposite scheem at various place under edd-sadabad hathras. - safe carriage of following material from electricty store center hts to pit site of work through the kacha and pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, t&p, etc. which required for proper completion of work.(distance 00-50 kms.), 8.5/9 mtr. long pcc poles., 9/11 mtr. s.t. poles, acsr weasel conductor, earthing complete, shackle insulator, stay set complete, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, 50/95/120 sqmm. ab cable, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, guarding angle with clamp, g.i wire 6/8/10 swg, neutral cum earth wire, cablejointingkit, 11 kv xlpe cable, 25 kva t/f, 63 kva t/f, 100 kva t/f, errection of following poles including cutting of kharanja/mettalic road/concrete portion while digging pit & complete h.t./l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work., pcc poles 8.5/9 mtr., stp 9.0/11 mtr., errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost., fixing of earthing rod as per respo norms and as per direction of supervising engineer., safe installation of following new/repaired cousted t/f on newly constructed double pole in proper alignment direction & making all ht/lt connection., 25 kva t/f, 63 kva t/f, 100 kva t/f, laying, sagging and stringing and jumpering / binding etc. of new & old acsr weasal conductor / gi in 11 kv / lt lines as per respo manual and as per direction of supervising engineer., acsr weasal conductor, 50/95/120 sqmm. ab cable, xlpe cable, providing & fixing of following clamps, 11 kv x arms clamps for stp/pcc pole, nut,bolt & washer, 11 kv f clamp for stp/pcc pole, earthwire clamps, lt clamp with nut & bolt, cablejointingkit, cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer, guarding/reguarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x-guards (tillis) of gi wire at distance of 3 mtr., installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the "t" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material., dismentlling and removal of existing line from the various area, dismentlling of pole stp/pcc, back cartage, acsr weasel conductor scrap, iron scrap