Get complete information related to latest Cable Tv Service Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable Tv Service Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable Tv Service Tenders.
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou
Tender For corrigendum : providing of integrated security surveillance system service - remote video monitoring, monitor operations, event video surveillance; recording devices, surveillance/nas; maximum security footage, high media quality; buyer’s premises; na; na; na; na; yes
Tender For providing of integrated security surveillance system service - theft prevention, remote video monitoring, facility/asset protection, monitor operations, employee safety; capture devices, recording devices; high media quality, maximum security footage; buyer’s pre..
Tender For providing of integrated security surveillance system service - theft prevention, parking lots, event video surveillance; recording devices; maximum security footage; buyer’s premises; na; na; na; na; yes
Tender For providing of integrated security surveillance system service - office security; recording devices; nvr system; na; na; biometric; na; na; no
Tender For providing of integrated security surveillance system service - remote video monitoring, theft prevention, facility/asset protection, employee safety; recording devices, capture devices, cloud storage; high media quality, ability to archive footage; buyer’s premis..
Tender For supply of microprocessor based electronioc speed indicating, recording system and 01 (one)evaluation soft ware for every 10sets of spm (without memory card reader unit &communication cable for master to slave) for wag-9/wap-7 & wap-5 type 3phase locomotives. drg. no./ spec. no :- rdso specn no.elrs/spec/spm/0002,rev-4 with latestspecn: rdso specn no.elrs/spec/spm/0002,rev-4 or latest. [ warranty period: 30 months after the date of delivery ]
Tender For providing of integrated security surveillance system service - theft prevention, remote video monitoring, facility/asset protection, monitor operations, employee safety; recording devices; high media quality, ability to archive footage; buyer’s premises; na; na; ..
Tender For corrigendum : providing of integrated security surveillance system service - theft prevention, remote video monitoring, facility/asset protection, monitor operations, vandalism deterrence; capture devices, recording devices; ability to archive footage, maximum security footage..