Get complete information related to latest Cell Holder Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cell Holder Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cell Holder Tenders.
Tender For repair renovation of advance make lrs installed at punjabi bagh bps in ac 26 - spares for 200kw lrs-moving electrode contact, fixed electrode contact, limit switch with roller action for start & run., power contactor for shorting, auxiliary contact block with 2no+2nc block, spares for 220kw lrs-moving electrode contact, fixed electrode contact, support insulator with hard wares, limit switch with roller action for start & run., power contactor for shorting, bus bar set for shorting contactor, geared pilot motor 0.5hp, ms chain set with garari both side, dismantling of existing lrs damage parts, cleaning of starter tank and overhauling of lrs starter. replacement of defective/overheated spare parts from starter taping of all i/c aluminum cable joint properly and replacement of thimble if required and proper greasing of movable parts as required. changing of water in lrs, mixing of chemical solution for proper resistance restoration, rectification and matching of all control wiring for main motor with necessary connection. and testing the same at site on load
Tender For supply of bch make starter spare parts - bch make contactor 16 amp., bch make contactor 25 amp., bch make over load relay 13.20 to 20 amp, bch make over load relay 17.4 to 24 amp, bch make over load relay 22 to 30 amp, bch make over load relay 23 to 32 amp, bch make spare kit sp 90 b 1
Tender For supply of spares for central air conditioning system switchyard air conditioning system split and window air conditioning system and water cooler system installed at 330 mw dccpp dholpur - control room spare parts of central ac plant model no. wcus027 dmn, compressor power 12x2 watts, capacity: 81000 cal. per hrs. make : voltas ltd., performer scroll compressor 13.5 ton model no. sm-185-s4rc danfoss commercial compressor, blower bearing (model ucntnp-206), v-belt 0b-1260/b-48 (3 belts in a set), danfoss eliminator filter drier (model no: 023z5010), over heat belt (c-heater belt 2c-65w-230v), aux. contactor siemens (model no.: 3tf3200oa), coupling (model utkarsh uws 110/100) complete set, split ac, compressor 2 ton whirlpool, blower whirlpool ( ac model: sar22b18mc0), blower motor whirlpool ( ac model: sar22b18mc0), outdoor fan motor whirlpool 2 ton ac (model: uc-055 900rpm 230v 0.60a), blower motor voltas (model: yyr20-4a9spg), blower motor videocon (model no.: ydk-18-4 18w-220 v 50 hz), pcb voltas 1.5 ton, pcb whirlpool 2 ton, pcb videocon 1.5 ton, pcb logicool 1.5 ton, copper pipe , copper pipe , aux. contactors (model: siemens 3th3022e), running capacitor 50 mf, 450 v, ac, capacitor for indoor unit 2.5mf, compressor for 1.5 ton ac (voltas, logicool, videocon), copper air filter for outdoor unit, spare part for switchyard package ac (make: voltas) model: deu85c make, (condensing unit) model no.: dcusc875d. capacity 7.5 ton each, performer scroll compressor 7.5 ton model no. sm-120-s4vc danfoss commercial compressor., v-belt a-620/a23 (2 belts in a set), outdoor control card voltas (model no. : voltas vdsu04a1), indoor bearing (model no. : ucntnp-205), emerson eliminator filter drier (model no: ek 165), copper pipe for suction line (30 mm pipe size), spare part of blue star water cooler, fan motor with blade-230v 1 phase 1360 rpm 0.40a (model: b329), compressor with relay, relay, over load relay (olr) suitable for blue star water cooler, air filter
Tender For supply of spare contractor coil set: coil voltage - 250-500v, ac 50/60hz, suitable for abb make p ower contactor use in lhb power car, 630 amp, 3 pole, 1000v, 50hz, model no. af-750-30-11, make: contactor coil part no.- zaf-750-71. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of esp spares for unit-7,wtps. - l&t contector-ss91010 3pole 300a 3ph,ml12 2no+2nc, spare kit w/o coil for ml-12 contactor,ss95317, spare coil for ml10/ml11/ml12 contactor cat. no. ss91011, make - l & t, side mounting add-on aux. contact block cat no-ss91474 for l & t make contactor type-ml-12, handle shaft for c&s make switch fuse unit, 200 a-800a, tc make panel door handle moulded cssdf 630a-800a cswh 220 s12)
Tender For corrigendum : lifts (passenger & goods), technical confirmation list for lifts (passenger & goods, job specification (static & machinery equipment), for lifts (passenger & goods), data sheet for lift (000-lz-l01 a/b), data sheet for lift 1000-lz-l02), data sheet for lift (000-lz-l03), location & landing platform for lift in pfs shed of sru, instrumentation cum mechanical building, standard specification for electric fraction lift, vendor data requirements, job specification for lifts, vendor data requirements for lifts, maridatory spare list (electrical)-lift package, approved vendar list (electical)-lif package, data sheet mv ind motor for lift, data sheet vfd for lifts, data sheet lift package pdb, data sheet mv swbo compilift package), hardware datasheet for outgoing motor feeder (rating55kw), hardware datasheet for outgoing mccb leeder, hardware datasheet for outgoing mccb contactor feeder, specification for mv switchboards fixed type for package equipment, specification for industrial type control stations, specification for medium and high voltage cables & accessories, specification for communicaton and fire alarm cables., specification for energy efficient medium voltage induction motor, specification for electrical equipment installation, specification for cable installation, specification for lighting installation, specifications for earthing installation, specification for electrics of package equipment, itp for mv fored hype switch board for package equipment, itp for industrial type control stations, itp for mv vanable frequency drive system, itp for my & hv cables & eccessories, itp for communication & fire alarm.cables, inspection and test plan for energy efficient medium voltage motors, equiment earthing schedule, instructions to vendor for sile performance guarante, requirements for peckage units, standard specification for health, safety & environmental management at construction sites, specification for quality management system requirements from bidders, specification for documentation requirement from contractors, specification for documentation requirement from suppliers
Tender For supply of spares of motor starter of pfff cooling towers - low voltage 320 a, 3p, 50ka moulded case circuit breaker (mccb). make: l&t model: dsine dn3-400m , main delta contactor of starr delta starter, ac3 duty 3p 250a make: l&t model: mo250 , star contactor of star delta starter, ac3 duty, 3p,95 a with auxiliary contact (1no+1nc), mo-ta2. make: l&t model no m095 , mpr with protection of overcurrent/earth fault/locked rotor and single phasing with 230 v ac supply. make: l&t model: mm10240e005 , low voltage protection class current transformer 320/5a, va 15, class 5p10 make procon model rcct110110r55 , low voltage air circuit breaker, 4p,1250a 50ka, makc: l&t model, omega w1-12n , low voltage air circuit breaker of 1000 a, 4p, 50ka make: l&t edo type model no: omega wi-10n , 100 a, 3p, 50ka moulded case circuit breaker (mccb) make: lal model dsine dno-100 m , ac3 duty, 70 a power contactor (main and delta) with 230 v ac control supply make: l&t model: mo70 , ac3 duty, 3p,50 a power contactor with 230 v ac control supply make l&t model: m050 1 , ct 2 starter spare thermal overload redery.
Tender For for procurement of required spare parts suitable for ducted ac system at 400 kv sub station unnao - 5.5 tr compressor scroll (emerson copeland make) suitable for air cooled ducted air conditioning unit of 16.5 tr (hitachi make, r410a only refrigerant use) as per existing model/specification -model no. - zp72kce-tfd-522, capacity 49500 kcal/hr, power supply 415 volts, 3 ph, 50hz a.c., imax-15 amps., indoor cooling coil suitable for 16.5 tr air cooled ducted air conditioning unit of size 32x54 inch, four rows (hitachi make) made of 100% copper as per standard make/sample as original model no:- microcool - mpa0198emd3., pcb control unit of standard make suitable for air cooled ducted air conditioning unit 16.5 tr (hitachi make, r410a) - new pac controller model no:- pag198euda3., 3 pole, 415v ac contactor, coil voltage 240 volt suitable for hitachi make ac plant, 32amps.
Tender For tender for supply of lauritz knudsen make 3 pole power contactor mnx 400 110vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 300 110vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 110 110vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 70 110vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 70 240vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 32 240vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 18 110vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 25 110vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 32 110vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 185 110vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 140 110vac refer attached detailed specification , lauritz knudsen make 3 pole power contactor mnx 250 110vac refer attached detailed specification , lauritz knudsen make spare contact kit for mnx 18 refer attached detailed specification , lauritz knudsen make spare contact kit for mnx 25 refer attached detailed specification , lauritz knudsen make spare contact kit for mnx 32 refer attached detailed specification , lauritz knudsen make spare contact kit for mnx 70 refer attached detailed specification , lauritz knudsen make spare contact kit for mnx 400 refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 24a to 40a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 14a to 23a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 0.3 a to 0.5 a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 0.2 a to 0.33 a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 0.45 a to 0.75 a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 0.6 a to 1 a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 0.9 a to 1.5 a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 1.4 a to 2.3 a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 2 a to 3.3 a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 3 a to 5 a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 4.5 a to 7.5 a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 6a to 10a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 9a to 15a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 20a to 33a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 30a to 50a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 66a to 110a refer attached detailed specification , lauritz knudsen make thermal overload relay mn2 45a to 75a refer attached detailed specification , lauritz knudsen make side mounting add on aux. contact block mnx 95 to 650 first right 1no with 1nc refer attached detailed specification , lauritz knudsen make side mounting add on aux. contact block mnx 95 to 650 second right 1no with 1nc refer attached detailed specification , lauritz knudsen make side spare coil for power contactors mnx 9 to mnx 40 110v 50hz refer attached detailed specification , lauritz knudsen make side spare coil for power contactors mnx 9 to mnx 40 240v 50hz refer attached detailed specification , lauritz knudsen make side spare coil for power contactors mnx 50 to mnx 80 240v 50hz refer attached deta