Tender For laying cementconcreteflooring, 4 cement seats and minor repairs in front at karur primary health center in karur g.p in ranebennur taluk of haveri district.(resreved for sc category)
Tender For bid to ras supply of indoor badminton court with and allied accessories c c - designing and construction of double howe adjoining flat truss- , construction and installation of mild steel column , installation of structure purling , fixing and installation of cross member , covering fixing installation of entire structure with 0.63 millimeter galvanized metal sheet , construction and installation of water drainage plan , painting entire structure with 02 coats of red oxide 02 coats of enamel paint colour chosen by user , construction of reinforced cementconcreteflooring , 12 millimetre wooden tiles approved by user 800 sqft , designing and installation of glass doors and windows , installation of toughen glass door used in heavy duty aluminum frame having size of 4 x 8 feet , auto soft close machine system for all doors stainless steel handles will be placed , construction of reinforced cementconcrete brick wall for entire sports complex , installation of qty 16 x 200 watt non-masked led lights , specifications of synthetic floor mats for badminton courts are as under , quantity of net poles posts 04 badminton world federation specification 02 x badminton nets make yonex ) /bid number : gem/2025/b/6986783 * /dated: 10-12-2025 & & / bid document 1 / 22
Tender For tender for supply of sitc of air conditioner : : -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1391 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters auto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply. the indoor unit shall be suspended from the ceiling using threaded rods- including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required. , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealedscrollrotary compressor and eco friendly refrigerantinitial charge of refrigerantcondensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply. the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floorlaying and interconnection of standard-length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required. necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no. 1 2 , supply laying of 4c x 2.5 sqmm frls pvc insulated 1.1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1.2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required. , supply and fixing of 75mm dia minimum 1.8mm thickness pvc covering pipe using necessary bend collor clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25x25x5mm l angle frame including clamps bolts nuts vibrating dampers as required for mounting of outdoor unit. , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar to match for the surrounding as required after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling.
Tender For corrigendum : r and r work for providing drainage channel and cementconcreteflooring at tower no. 75 of 400kv dehar-panchkula transmission line.