Tender For asset management services - asset to be valued; onsite-supply of equipments:- variable refrigerant flow system, outdoor unit(s) - heating & cooling, 8hp outdoor unit, , indoor unit, ductable type units, ductable type unit 5.5 tr, , split units , split units 2.0tr, , , refrigerant joint(s), indoor refnet joints , controllers, central remote control, twining kit, pcb safety plate controller, installation of airconditioning system of following items--lifting, shifting, installation, testing and commissioning of outdoor units equiped with highly efficient varaiable speed scrool compressors in each outdoor unit with noise level not exceeding 70db(a), etc. with nitrogen reprocessing, vacumising, charging and top-up of r410 a gas as per requirement at site. (r410a gas make-dupont/honeywell) , lifting shifting & installation of outdoor units - 8hp , tesing & commissioning charges - 16hp , vacuum, nitrogen reprocessing & r410a- refrigerent topup -16hp , lifting, shifting, installation, testing and commissioning of indoor units with outer cabinet equiped with pre air-filters, multispeed inverter motor, dx coil section, drain pain,electronic expansion valves, pipe connections, pcbs etc. (fastener make- hilti) , , , indoor unit(s), ductable type units, ductable type units, ductable type unit 5.5 tr, , "supply, installation, testing and commissioning of refrigerant piping, tees, sockets, expanders and reducers as per requirement at site complete with supports, threaded rods, channel, tie, fasteners etc. interconnecting the outdoor condensing units and indoor evaporating units. (make-mandev/mexflow), nitrile rubber tubular insulation (make-supreme/superlon/armaflex/a-flex/k-flex/equivalent)" , "supply, installation, testing and commissioning of 2 core x 1.5 sq.mm copper conductor shielded data cable as per requirement at site complete with supports, threaded rods, channel, tie, fastners etc. for control between indoor and outdoor unit & for communication between indoor unit & remote controllers in suitable pvc conduict , (make- polycab/havells)" , , supply, installation, testing and commissioning of pvc condensate drain piping of 10kg/sq.cm. (142.23 psi) with 6 mm thick closed cell elastomeric nitrile rubber tubular insulation up to the nearest drain point along with necessary fittings.(make- prince/supreme/finolex/polycon/equivalent) , supply, installation, testing and commissioning of hot dipped 20 gauge g.i. perforated trays for exposed refrigerant pipes and cables horizontaly and vertically along with threaded rod, nut, bolt, saddle, tie etc. , , supply, installation, testing and commissioning of un-insulated square/ rectangular sheet metal ducts as per requirement at site complete with threaded rods, channel, tie, fastners, brackets/slotted "c" channel for supply air ducting as per the approved shop drawings jindal, sail, tata. , , supply, installation, testing and commissioning of closed cell crossed linked polymers xlpe insulation , , supply, installation, testing and commissioning of acoustic lining with 10 mm elostomeric sinusoidal surface acoustical insualtion. , , supply, installation, testing and commissioning of extruded aluminum powder coated supply air grills/difusers with dampers and return air grills/diffusers without dampers. , supply/return air grills/diffusers with volume control dampers , supply, installation, testing and commissioning of nrv , , supply & installation charges of accessories fire retardent canvas connection & filters as required for duct type indoor units. , ms-stand for odu unit , ms-jaal , civil work chase cutting for copper/drain pipe , civil work rcc corecut/chase cutting for copper/drain pipe , annexure-iii-electrical installation and accessories-panel for 16hp odu , design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following lt panels fabricated out of 18 guage crca sheet steel in cubical formationwith reinforecment of suitab
Tender For upgradation augmentation of shot blasting equipment and shot blasting room including replacement of three motor driven screw lp air compressor for upgradation augmentation of production shop floor (ab and ac bay) at ins eksila - upgradation/ augmentation of shot blasting equipment and shot blasting room including replacement lp air compressor as indicated in part-ii of rfp consists of the following:-, dismantling and degutting of lp air compressors along with all associated equipments and shifting work as specifiied in para 1(1.1)(a) part ii of rfp., lp air compressor, lp air compressor as specifiied in para 3 (3.1) part ii of rfp., dryer unit as specifiied in para 3 (3.1) part ii of rfp., air receiver tank (2000 liters) as specifiied in para 3 (3.1) part ii of rfp., air filter as specifiied in para 3 (3.1) part ii of rfp., acoustic canopy as specifiied in para 4 (4.1)(a) & (b) part ii of rfp., electric power distribution board/ control panel as specifiied in para 4 (4.1)(d) part ii of rfp., dismantling and degutting of shot blasting system along with all associated equipments and shifting work as specifiied in para 1.2 of part ii of rfp., shot blasting system, protection liner & rubber lining as specifiied in para 3(3.2) part ii of rfp., recovery unit as specifiied in para 3(3.2) part ii of rfp., dust collector & exhaust system as specifiied in para 3(3.2) part ii of rfp., shot blasting unit as specifiied in para 3(3.2) part ii of rfp., all other items associated with main eqipment which are mentioned in part ii of rfp [ex para 6(a) & 6(b) etc] part ii of rfp)., civil work for (refers to para 8 of part ii of rfp)., standard accessories (refers to para 9 of part ii of rfp), two years operation & maintenance spares (refers to para 10 of part ii of rfp), special maintenance tools and test equipment (refers to para 11 of part ii of rfp), technical literature / certificates / documentation (refers to para 13 of part ii of rfp), acceptance, testing, trials and commissioning charges (refers to para 14 of part ii of rfp), training (refers to para 16 of part ii of rfp), any other item such as transportation, insurance, freight, packing etc, notes:1. cost of item listed at sl 1 to 12 and 13 (if applicable) are to be quoted in the respective rows of the price bid sheet. 2. bidder not permitted to include cost of items listed at sl 6 to 13 with sl 1 to 5 as lumpsum amount 3. bidder required to mandatorily quote for sl 1 to 5 and 12 failing which bid shall be treated as non bonafide and liable for rejection.4. bidders are mandatorily to quote gst/ taxes as applicable against each serials, falling which bid shall be treated as non bonafide and liable for rejection.