Tender For in the electricity distribution sub-division-sarila under the area of electricity distribution division-rath (1) work of installing new poles and wires in the main line of jitkari feeder in 33/11 kv electricity sub-station jhabra (2) work of installing new poles and wires in the main line of ichaura feeder of jitkari feeder in 33/11 kv electricity sub-station kheda.
Tender For repairing and replacement of damaged 600 mm dia psc pipe of mukherjee park feeder main infront of amrit deep hospital near of all india radio vrindavan road under mathura vrindavan municipal corporation in deposit programme
Tender For p/l 200 mm di pumping main from tilak vihar ugr to nearby gali no. 1 lakdiwala pul santrgarh including interconnection in the streets and p/l 200 mm dia di by-pass feeder pipe line from near mbs nagar ugr/bps to interconnect with existing 200 mm dia
Tender For work of providing and laying of 150&100mm dia di pipeline with linking to feeder pipeline along with di valves at doresanipalay, venkatadri layout, panduranga nagara, bannerughatta main road coming under arekere mico layout service station of aee(s)-1-1 sub division. call-2
Tender For work of providing and laying of 300mm dia feeder main to chandranagar from kanakapura main coming under yelachenahalli service station of aee(sw)-5 sub division
Tender For renovation of internal electrification in the main building of sukanta academy for science, arts and culture and provision for double feeder facility with armored cables and panels for journey to sun via mars including internal electrification of 02
Tender For upgradation of main feeder panel near new badminton court and installation of 3 nos additional sub feeder panel in cricket ground 1 and interconnection of feeder panel near siang hostel to new badminton court feeder panel in the iitg campus
Tender For repairing of 800amps abc make switch type flp, acb, 550volts, sl.no.phu/lt/acb/04 for controlling of feeder breaker main switch of phularitand, amp colliery.
Tender For work of providing and laying of 150mm dia di ws feeder line in kathriguppe main road and in gangamma gudi road from 2nd cross road to 7th cross road along 4th main, 100mm dia di ws line along kathriguppe main road at 9th 10th and 11th cross roads ashoknagara and surrounding area coming under mountjoy service station of aeesw-3 sub-division
Tender For maintenance- repairs- replacement of electrical items for various projects executed under srinagar smart city limited for a period of 2 years. - supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage, delivery and erection of following sizes of distribution transformer at site., i) 630 kva distribution transformer, ii) 400 kva distribution transformer, iii) 250 kva distribution transformer, iv) 100 kva distribution transformer, v) 63 kva distribution transformer, fixing of fabricated gi angle/channel/flat/pole collars., fixing of galvanised nuts and bolts., supply, installation, testing, commissioning, insurance, unloading, carriage and delivery at site, laying, stringing and binding of conductor including joints with pg clamps of required following size of acsr conductor (0.1 /0.05/ 0.03), i) 100 sqmm acsr (dog), ii) 50 sqmm acsr (rabbit), iii) 30 sqmm acsr (weasel), supply, installation, testing, commissioning of ab (ht) cable of following sizes:, iii) 50 mm ab (ht) cable (3x50+1x70 mm ) xlpe(11 kv, 3c +earth), iv) 70 mm ab (ht) cable (3x70+1x95 mm ) xlpe(11 kv, 3c +earth), v) 95 mm ab (ht) cable (3x95+1x95 mm ) xlpe(11 kv, 3c +earth), vi) 120 mm ab (ht) cable (3x120+1x95 mm ) xlpe(11 kv, 3c +earth), mid span straight through jointing kit for 11 kv abc of following sizes:, i) 11 kv abc 50-95mm straight through jointing kit (3 core), ii) 11 kv abc 120-185mm straight through jointing kit (3 core), iii) 11 kv abc 240-300mm straight through jointing kit (3 core), heat shrinkable outdoor cable termination kit for ht/lt abc of following sizes:, i) 11 kv abc 70-95 mm outdoor cable termination kit, ii) 11 kv abc 120 mm outdoor cable termination kit, iii) 11 kv abc 150-185 mm outdoor cable termination kit, iv) 11 kv abc 240-300 mm outdoor cable termination kit, supply, installation, testing, commissioning of ab (lt) cable of following sizes:, ii) 50 mm ab (lt) cable ( 3x50 + 1 x 16 + 1 x 35) mm xlpe (1.1kv, 3+1 c, al), iii) 70 mm ab (lt) cable (3 x 70 + 1 x 16 + 1 x 50) mm xlpe (1.1kv, 3+1 c, al), iv) 120 mm ab (lt) cable (3 x 120 + 1 x 25 + 1 x 95) mm xlpe (1.1kv, 3+1 c, al), straight through cable jointing kit for lt abc of following sizes:, ii) 50 mm ab (lt)straight through cable jointing kit, iii) 70 mm ab (lt)straight through cable jointing kit, iii) 120 mm ab (lt)straight through cable jointing kit, dismantling, i) dismantling, stacking of 9/8 mtr st poles and transportation back to divisional store as per the instruction of electrical incharge., ii) dismantling of 0.03/0.05/0.1 acsr conductor and transportation to divisional stores (servicible), servo voltage stabilizer, i) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 63 kva, 3-phase oil cooled servo (complete job), ii) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 50 kva, 3-phase oil cooled servo (complete job), rmu, supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 4 way type,two isolators and two circuit breakers 11 kv, ring main unit ,sf6 insulated, out-door type, extensible type,breaking capacity 25 ka for one second with sf6 circuit breaker / vcb self powered with o/c + e/f relay comprising of a) 11kv 630 amp motorised isolator including earthing switches with making capacity 52ka, having mechanical on/off, earth indications with fault current indicator.b) 11kv ,400 amp motorised spring operated, circuit breakers with earthing switches, connecting the rmu to supply transformer. c). copper bus bar of 630 amp rating.d). 1 no numerical aux. powered relay having non directional o/c and e/f protection (for each ciruit breaker).d). the circuit breaker enclosures shall be outfitted with a communicable-type numerical (feeder p