Tender For supply of chilled water piping 50mm diameter , gss duct 0 point63mm thickness , supply air grills with volume control , return air grills without volume control , duct insulation nitrile rubber 19mm , cooling coil 24 tr capacity , blower with motor , cooling coil 12 tr capacity
Tender For supply of 24baic003 boq--lamp indicating blue 230vac, switch on-off (toggle-black), rotolock valve level transmitter, fuse glass 5a, lamp indicating red 230vac, lamp indicating yellow 230vac, mcb 5sl4210-7rc, expansion board, solenoid valve, mpcb for blower, electric regulating valve, one card of each type of the controller & compressor, plc module set, flow switch set, set of all fuse links (fuse set (one of each type), set of all filters in the gas line, set of all power capacitors, set of all valves in sea water chilled water and gas lines, set of all hmis, pressure gauge set, set of all analog gauges, set of all cut outprotections (both compresr elec panels), set of all zinc anodes, set of all push buttons, set of all o rings (rubber and teflon), pump shaft cw pump, pump shaft sw pump, set of all transformers, mcb 5sl41027rc (2a), pressure relief valve, check valve 4, butterfly valve for suction line, electronic expansion valve, drier for motor cooling line, manifolfd brass 1 1 8
Tender For supply of scavenge blower to tm/oil cooling unit including motor (wound with corona resistance wire) to specn. no. (i) clw/es/3/0021 alt-h or latest & (ii) spec/e-10/3/09 with amendment 01 to 06 (motor)
Tender For supply of motor for traction motor cooling blower for locomotive( mvmt-h class)specification/drg. :- clw specn.no -clw/es/b-14/alt-c with latest alt. pt.ii
Tender For supply of impeller suitable for traction motor cooling blower (mvmt) 24 blade design as per clw specification no. clw/es/b-14/c or latest if any.
Tender For supply of item no.1) (uvam id.2100012) blower scavenge for traction motor & oil cooler along with motor for oiltypes of 3 phase locos as per clw spec. no. clw/es/3/0021/h or latest and rdso specn. no. e-10/3/09 [motor] withamendment nos. 01 to 06 or latest.item no. 2) (uvam id.2100034)traction motor blower including motor (wound with corona resistance wire) to specn. nos. clw/es/3/0019/g or latest and rdso spec. no. e-10/3/09 motor with amendment nos. 01 to 06 or latest.item no. 3) (uvam id.2100013)oil cooling blower unit complete with casing and blower for 3-phase wag-9 locos as per clw specn.no. clw/es/3/0647, alt-e or latest and rdso specification no. rdso/2016/el/spec/0123, rev.0 or latest.item no.4) (uvam ido.2100003)machine room blower with motor as per clw spec. no. clw/es/3/0020 alt-h or latest.item no.5) (uvam id.2100006)scavenge blower to machine room as per clw specification no. clw/es/3/0022 alt-h or latest andmotor for scavenge blower (mr) (wound with corona resistance wire) as per rdso specification no. spec/e-10/3/09 motor withamendment nos. 01 to 06 or latest.
Tender For supply of scavenge blower to tm/oil cooling unit including motor (wound with corona resistance wire) as per clw's specn.no.clw/es/3/0021 alt-h and rdso spec. no. rdso/spec/e-10/3/09(motor) with amendment nos. 01,02,03,04,05 & 06. or latest.
Tender For replacement of em items against ber held with ge i rnd east bangalore - supply, installation, testing & commissioning of double skin horizontal air handling unit of fully capacity, complete with double skin insulated with cfc free foam (puf) panels of 25mm thick, 42 kg/cum density. sandwitched between 0.6 mm thick g.i. sheets. outer skin shall be pre coated g.i. sheet pre coated off white. ahu frame works shall be of pre cast vertical and horizontal extruded aluminium profile with three way corner frame sections. frame construction should bear the load of structure and load of the frame structure shall be uniformly distributed along the entire housing of the ahu. food grade self adhesive coated neoprene gasket to be provided between panels and structure of the ahu to ensure the entire housing is airtight., backward curved blower to be supplied along with motor (kruger/nicotra). filter will be of 10 mic as pre filter, 3 mic as fine filter. cfm as below with 60-80mm sp complete all as specified and directed., note: rate quoted to be deemed to include civil works for hvac like breaking and opening for entry and exit of supply ducts from ahu room, exhaust ducts into shafts for exiting copper pipes / drain pipes also. fire rated material of 25mm thick phenotherm to be used near civil closures for fire resistant properties., a) 13200 cfm, 60mm static ahu capacity 33 tr., 11 tr dx outdoor ac unit complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a minimum capacity.note: rate quoted to be deemed to erection of condenser unit platform (ms angle frame with 02 coats of red-oxide and 01 coat of enamel black paint) with ms works for duct support., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 22 tr ducted packaged ac unit with 8800cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 11 tr ducted packaged ac unit with 4400cfm complete all as specified and directed., supply, installation, testing & commisisioning of nominal capacity air-cooled dx floor mounted packaged ducted units complete with scroll compressors, copper tube aluminium finned air cooled condensers, propeller type condenser fans with eco friendly r410 refrigerant & powder coated outer metal body controlling a capacity of mimimum 8.5 tr ducted packaged ac unit with 3500cfm complete all as specified and directed., supply, installation, testing & commissioning of air cooled ducted split air conditioners of capacity 8.5 tr with r2 series: r 407c eco friendly refrigerant, nominal cooling capacity 1,02,000 btu/hr, nominal air flow 3400 cfm, microprocessor based with lcd display controller and hermetically sealed scroll type compressor, all necessary connections with suitable size of copper cables and initial gas charging, provision of necessary pcc platform / iron angle frame for outdoor unit complete all as specified and directed by engineer-in-charge., dismantling / taking down / transporting carefully old acs outdoor & indoor unit with all connected acessories and to be deposited in mes store complete all as specified and directed., dismantling / taking down / transporting carefully old unserviceable ducting items off any size and capacity with all connected accessories and to be deposited i