Tender For supply and installation of boosting pump and rotameter for gaseous chlorination system and miscellaneous works under sutaboi w/s scheme under pmd, phe dte. in the district of purulia.
Tender For procurement of miscellaneous items for unit 4 overhauling, sgtpp - sgtpp, air filter, complete set, 250 srs filter for paph/saph [500 mw boiler] air motor veljan , port size 1inch bspt (body ported), max pressure10 bar having 40 micron sintered bronze filter element with manual drain, alumin wl & nitrile seals ( (oil side set) ), bowl of air filter for air motor of paph/saph [500 mw boiler] veljan with manual drain suitable for 250 srs filter,moc: poly carbonate. ( (oil side) ), silencer (pn:400450035) for air motor of paph 400450035 iec dusterloh ( for paph & saph air motors ), hose barb/nipple size 3/4" mnpt x 1/2" ( hose nipple 1/2 "x 1/2 "-120 nos and hose nipple 3/4 "x 1/2 "-80 nos. outer thread at one end and one end will be fitted with 1/2" rubber hose moc: ms application area: air boosting line at mrhs [quoted as per additional text description] ), needle valve,ss316 ( size: inch 3000 psi ,moc ss 316, ferrule end connection make:baldota. [quoted as per additional text description] ), flexible hose, id-12.7 mm, l-613 mm, for oil gun 500mw boiler , moc: ss 304, ms split pin # ( ms split pin, size: 4x80 [quoted as per additional text description] ), split pin # ( ms split pin, size: 3x80 [quoted as per additional text description] ), rubber hose size 1/2" ( 1/2 inch flexible rubber hose. moc: high quality braided rubber application area: at dome cooling water line of mrhs. [quoted as per additional text description] ), jubilee clamp; size: 1 ( jubilee clamp: 1/2 inch application area: at hose of air boosting line at mrhs. moc: gi [quoted as per additional text description] ), expansion joint,mrs,mill xrp 1003 for mill xrp 1003 dia- 241 mm., length- 210 mm. ( expansion joint,mrs,mill xrp 1003 for mill xrp 1003 dia- 241 mm., length- 210 mm. with extra flange attached with inner sleeve,pressure rating - 3.5 kg medium - coal reject. minimum temp to be withstood-300 deg c. ), hose, seal air, mill xrp 1003 ss flexible hose, od - 64 mm. length - 900 mm.both side hex nut socket fittings, filter,suction,600x600x50mm,ss net 3layers,5 micron ( application: for ac & dc scanner air fans ), loctite super glue in tubes 013 gms/2gm tube ( loctite sl 5910 each contains: (300 ml) [quoted as per additional text description] ), loctite 270 (thread lock) # ( loctite 241 each contains: (50 ml/51.3 g) [quoted as per additional text description] ), stainless steel net, width:470mm for 500 mw boiler trough seal , wire thickness: 5 mm, square gap:11 mmx11mm, moc: ss 416., lubricating paste altemp q nb 50 for pa & fd fan make- kluiber ( total 5 nos of tubes. each tube contains 80 gm ), strainer for blowdown transfer pumppart no-15 wpil pump model: vo wpe 80-400/ 100-320,drawing no. bvk-50150-151/50152-153/50154-155, moc:ms ( application: boiler blowdown pump moc: ms ), shaft set,moc- ss410,vo wpe 100/320 for blowdown transfer pp vo wpe 80/400 & 100/320 pt no-7 wpil for pp sl no. bvk-50150-151/bvk-50152-153/bvk-50154-155 ( 4 sets: slightly larger, 2 sets: slightly smaller dimension as per drawing ), screw,self drill,washer,5.5x25mm ( hex flange head-pvc washer blue zinc coated-coarse thread size: 5.5x14x25 mm make: welfast ), coupling sleeve for blowdown transfer pump wpil part no-21 wpil pump model: vo wpe 80-400/ 100-320,drawing no. bvk-50150-151/50152-153/50154-155,wpil,moc: ss 410 ( shaft sleeve /coupling sleeve-a. as per drawing of boiler blow down pumps spares ), shaft sleeve for blowdown transfer pump wpil part no-19 wpil pump model: vo wpe 80-400/ 100-320,drawing no. bvk-50150-151/50152-153/50154-155, moc: ss 410 ( shaft sleeve-b. as per drawing of boiler blow down pumps spares. ), rubber bearing ( rubber bush/cut less bearing, moc:inner: teflon, outer: brass (copper-85%, tin-85%, lead-85%, zinc-85%). as per drawing of boiler blow down pump#s spares (larger-10+smaller-5) ), bush bearing/ b. housing for blowdown transfer pump wpil part no-20 wpil pump model: vo wpe 80-400/ 100-320,drawing no. bvk-50150-151/50152-153/50154
Tender For corrigendum : repair of boosting station at canal, ss tank no.2, filter beds 8.22 m dia (3 no.) and 9.50m dia (1 no.), hlt 8.22 m dia, cwt 8.22 m dia, pump chamber 6.10 x 4.88, pipe line at head works, pumping machinery and other works
Tender For construction of boosting station, under ground tank, pump house and pumping machinery, electrification works, civil works in sector 40, ward no. 13, zone no. 3, devision no. 3a, gurugram, under mcg area
Tender For gatauli:- construction of raw water pumping station. constuction of 1 mld wtp , 2 nos. rcc s/s tank, 2 no. clear water tank, pump chamber with store, boundary wall with rcc column and pillar, pumping machiner at new water works. contraction of 1 mld wtp, boundary wall, pump chamber, repair of sands tanks and pumping machinary at old water works, construction of 1 no. boosting staion and renovation of existing boosting station, laying of rising main and distribution system and restroration of house connections in village gatauli distt. jind and all other works contingent thereto.
Tender For dnit name :construction of two no. s/s tank of mean size 74.68x88.57x3.66 - 2 nos., rw and cw suction well 2 nos., wtp 1.50 mld, rcc clear water tank of size 12.80x8.55x2.44m - 2 no., pump chamber - 1 no., pumping machinery, repair of existing w/w structures at water works, construction of new boosting stations 3 nos. at upkar colony, near girls college and sukh sagar colony, distribution pipe lines, oandm and mtc. of w/w, b/s-3 no. including distribution pipe line for operation and maintenance of water works for complete scope of work mentioned in the dnit and of whole existing water supply system in the village disinfection material supplied by the phed as per schedule iv for a period of 5 years after 12 months during defect liability period and 3 months trial run period. (will be charged to the annual mtc. estimate). complete in all respects as per approved nit at w/w village shah satnampura
Tender For corrigendum : khanpur kalan- annual maintenance w/s scheme khanpur kalan -repair of pump chamber, boundary wall and construction of path at boosting station in village khanpur kalan tehsil gohana distt. sonipat and all other works contingent thereto
Tender For providing and installation of 75 kw/100 hp centrifugalpump-motor set for searsole zone at searsole boosting station under rcfa part-ii water supply scheme
Tender For repair of boosting station at canal, repair of s ands tank no.2, repair of filter beds 8.22 m dia (3 no.), 9.50m dia (1 no.), repair of hlt 8.22 m dia, cwt 8.22 m dia, pump chamber 6.10 x 4.88, pipe line at head works, pumping machinery and other