Web Analytics Made Easy - StatCounter

Change Over Switch Repair Tenders

Get complete information related to latest Change Over Switch Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Change Over Switch Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Change Over Switch Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :39441393 Due date: 27 Feb, 202527 Feb, 2025 NA
Tender For supply of limit switch for meeting post

CTN :38956357 Due date: 27 Feb, 202527 Feb, 2025 NA
Tender For corrigendum : supply of pcc for pedestal , providing,mxng and plcng,rcc,1 is to 2 is to 4mix , structural steel , excavation in earth upto1.5mt,wbackfill , reinforcement steel , sply and lay of earth stripfixacc,25x3mm , sply layg of cable tray duct,gi,150mm , non flp 4k camera , box camera perimeter camera , hd ip camera mp2,flp enclosure , fixed non-flp camera , sply and instln of camera dome camera,te , sply and instln of ptz camera , server for cctv system , sply and instln of software cctv vms , video storage sys cctv sys , network server rack,42u , sply and instln of workstation client , sply and instl of 55in led tv , 8 port poe l2 n w switch , 12 port poe l2 nw switch , sply and instln of flp jb , liu , sply and instln of gi pole ht 9mt , sply and fixg of armoured cable size 3cx4mm2 , sply and layg cat6 network cable armoured , cat6 cable, n arm wpvc casing , sply and instln ofc cable armoured,6c , sply and layg of earth wire frls,cu,4mm2 , pipe,gi,is 1239,erw,50mm , exca for cbl trenchunderground,1000mm,10 , back filling of cable trench w , camc - 1st year post , camc - 2nd year post , camc - 3rd year post , camc - 4th year post , camc - 5th year post

CTN :39383734 Due date: 11 Mar, 202511 Mar, 2025 24.41 Lacs
Tender For tender for supply of electrical items - 20/36 watt led tube fitting , non integral type , 4x1 feet length having minimum luminous efficacy of 3600 lumen/watt , 9/10 w led lamp having minimum luminous efficacy of 100 lumen/ watt , 90-95 watt led street light luminaire with ip 66 protection and having minimum luminous etticacy 120 lumen/watt , 40-45 watt led post top lumiaire with ip 65 protection , 12 watt recessed/ surface mounted round led light fitting , having luminous efficacy of minimum 199 lm/w , 100 watt led flood light luminaire with ip 66 protection and having minimum luminous efficacy 120 lumen/watt. , surface/recess mounted 600x600 mm led light fitting , 36 watt having/luminous efficacy , recessed/ surface mounted round led light fitting , 18 watt having luminous efficacy of minimum 100 lm/w , 450 mm sweep pvc blade wall fan (heavy duty) , 1200 mm sweep bee e star rated , ceilling fan with brush less direct current (bldc) motor , 225 mm sweep light duty metallic body exhaust fan including louvers , fancy wall bracket fitting along with 9w retrofit led lamp , 5/6 a modular switch , 15/16 a modular switch , 3 pin 5/6 amp socket outlet , 6 pin 15/16 amp socket outlet , ac starter switch 25 amp , 5/6 a , 3-modular switch socket combined box , 5/6 amp , 3-pin plug top , 15/16 amp 3-pin plug top , stepped type modular fan regulator (2m) , call bell , modular call bell pushy , iron screw 40 mmx 6 mm , pvc gitti (1.5 inch) , cable clip with metal nails (8/10/12 mm) , casing capping (25x16 mm) , 1 sq. mm frlsh copper wire , 90 metre roll , 1.5 sq. mm. frls copper wire , 90 metre roll , 2.5 sq. mm frls copper wire , 90 metre roll , 4 sq. mm. fels copper wire , 90 metre roll , 3- core 6 sq. mm btc cable , 3-core , 1.5 sq. mm unarmoured copper cable , 3-core , 2.5. sq. mm unarmoured copper cable , 3-core , 4 sq. mm unarmoured copper cable , 6 - 32 amps single pole c miniature circuit breaker , 2.5 mfd fan capacitor , 3.15 mfd fan capacitor , pvc black tape , ampere tape/ bitumen tape , 33 kv lightening arrestor gl clamps bolts and nuts with washers , 36 kv 20 ka , class - 1 , 50 hz , 33 kv pin insulator with pin washers and nuts , 33 kv drop out fuse element , 63 amp , single phase energy meter , 5-30 amp , 3- phase energy meter , 10-60 amp , 9-10 watt led mirror light fiting having luminous efficacy of minimum 100 lm/watt , heating element of 15/25 ltrs capcity water heater , brass batten holder , 15/16 a , 3- modular switch socket combined box , 2 pin male female adapter plug top , casing pin , 6 mm x 75 mm steel fastner , 40 amps dp c miniature circuit breaker , 63 amps tpn c curve , miniature circuit breaker , 20 a wire connector , 400 amps , 33 kv drop out fuse connector

CTN :39350943 Due date: 03 Mar, 202503 Mar, 2025 NA
Tender For supply of flushing switch assembly ( 5/2 spool valve type ) pneumatic operated sp ecification 1. operating air pressure = 10 bar (maximum) 2. 5/2 spool valve type (5 port 2 posi tions) as under (a) - total port = 5 nos. (b) - inlet port = 1 no., depth : 10 mm. to 12 mm., threa d diameter : 1/8 inch or 1/4 inch. (c) - outer post = 2 nos, depth : 10 mm. to 12 mm., thread dia meter : 1/8 inch or i/4 inch (d) - exhaust port = 2 nos., depth : 12 mm. to 15 mm, thread diamete r : 1/8 inch or i/4 inch (e) - total length of flushing switch assembly (without knob plates) is = 130 mm. (approximately). [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :39171113 Due date: 03 Mar, 202503 Mar, 2025 1.80 Crore
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene

Central Government/Public Sector

CTN :38198472 Due date: 20 Feb, 202520 Feb, 2025 5.19 Crore
Tender For bid to ras corrigendum : sitc and camc of scctv system for isolation bay and cooling pit - 2 megapixel varifocal outdoor ptz dome camera , 2 megapixel varifocal indoor box or bullet camera , 8 channel nvr , desktop pc , 43 inches led display , 9u waterproof outdoor rack , l2 switch 24 port with 4x10g sfp ports , l2 switch 4 port industrial grade outdoor with 2x10g sfp ports , rf radio point to multi-point base station , cpe , cat 6 outdoor cable , frangible frp pole , 1kva industrial grade ups , supply, installation, testing and commissioning , training and documentation , camc for 1st year post warranty at the rate of 6 percent for item number 1 to 15 , camc for 2nd year post warranty at the rate of 7 percent for item number 1 to 15 , camc for 3rd year post warranty at the rate of 8 percent for item number 1 to 15 , rf radio point to point radio , camc for 1st year post warranty at the rate of 6 percent for item number 19 to 34 , camc for 2nd year post warranty at the rate of 7 percent for item number 19 to 34 , camc for 3rd year post warranty at the rate of 8 percent for item number 19 to 34 , camc for 1st year post warranty at the rate of 6 percent for item number 38 to 53 , camc for 2nd year post warranty at the rate of 7 percent for item number 38 to 53 , camc for 3rd year post warranty at the rate of 8 percent for item number 38 to 53 , camc for 1st year post warranty at the rate of 6 percent for item number 57 to 72 , camc for 2nd year post warranty at the rate of 7 percent for item number 57 to 72 , camc for 3rd year post warranty at the rate of 8 percent for item number 57 to 72 , camc for 1st year post warranty at the rate of 6 percent for item number 76 to 91 , camc for 2nd year post warranty at the rate of 7 percent for item number 76 to 91 , camc for 3rd year post warranty at the rate of 8 percent for item number 76 to 91 , camc for 1st year post warranty at the rate of 6 percent for item number 95 to 110 , camc for 2nd year post warranty at the rate of 7 percent for item number 95 to 110 , camc for 3rd year post warranty at the rate of 8 percent for item number 95 to 110 , camc for 1st year post warranty at the rate of 6 percent for item number 114 to 129 , camc for 2nd year post warranty at the rate of 7 percent for item number 114 to 129 , camc for 3rd year post warranty at the rate of 8 percent for item number 114 to 129

CTN :39366635 Due date: 21 Feb, 202521 Feb, 2025 1.58 Crore
Tender For supply of 11 kv roaster switch with 12 kv post insulator

CTN :39356828 Due date: 08 Mar, 202508 Mar, 2025 NA
Tender For supply of ply wood , service cable , wire roll , led halogen light , pin socket , socket , switch button , gain box , aggrigate , angular rod , screw , paint , bricks , brush , holder , cable , casing caping , fan , cement , cgi sheet , change over , copper wire , cord nylon , cutting plier , cutting wheel , distemper , electric wire , emery paper , fabric revetment , fan condensers , fiber sheet , flexible wire , float valve , brick , insulation tape , iron nails , iron square pipe , j hook , led bulb , led tube light , lighting conductor , m seal , mattress , mcb , mcb sp and dp , steel wire , nut bolt , pbs roll , plywood , post fence metal angle , power board , power cable , ppgi sheet , pt switch , puff door , pipe , rccb , ridge sheet , roof sheet , sand , saw hand , scaling piece , screw driver , service cable , shoulder gun , square block , ss combination , switch socket , taping screw , teflon tape , terracotta , tester , tiles , timber ballies , tube light , wash basin , water storage tank , welding rod , fiber glass , wire steel mild , wire stopper , wood cutting

corporations/Associations/Others

CTN :39322126 Due date: 12 Mar, 202512 Mar, 2025 7.85 Lacs
Tender For procurement of spare for 11 kv line gang switch - bottom base connector , drop out expansion connector , upper moving dropout connector , post insulator four hole type extended connector , upper moving arm -knife with arching rod , moving contacts holder with gi wire adjuster , copper flexible link -24inhx1.5inch

Central Government And Public Sector

CTN :39075342 Due date: 20 Feb, 202520 Feb, 2025 11.05 Lacs
Tender For corrigendum : supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sens
 Loading, Please wait...

Connect us via What's Up