Get complete information related to latest Chiller Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Chiller Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Chiller Tenders.
Tender For corrigendum : supply, installation, testing and commissioning of 02 no 105 tr air cooled screw type chillers along with up gradation of air handling units and fan coil units at govt. super speciality hospital, srinagar
Tender For comprehensive annual maintenance contract and day to day 365x24x7 operation of 2x80tr capacity climaveneta make air cooled screw chillers and associated equipments installed at agartala government dental college, agartala for a period of 01 year duri
Tender For comprehensive annual maintenance contract of the chillers and associated equipments along with day to day operation of the entire air condition system installed at nth i of agmc and gbp hospital, agartala for a period of 1 year
Tender For comprehensive annual maintenance contract and day to day operation of the chillers and associated equipments installed at nth ii, agmc and gbp hospital, agartala for a period of 1 year
Tender For supply installation testing and commissioning of 01 no of table top powder xrd at school of physics smvdu kakryal katra - supply and installtion of table top powder xrd with detailed specifications as follows:, x-ray generator: max. continuous rated output: 600 w guidance based software system, voltage: 20- 40 kv with increment of 1kv / current: 2 15ma with increment of 1ma (variable voltage and current). ht stability better than +/-0.01% for mains stability +/- 10 %.x-ray tube:cu target with 1000w and k-beta filter, should be upgradable for cr, co & fe.goniometer:high precision, vertical type, goniometer with theta two theta geometry, range: -3 to +1400 or better, radius: 150mm, scanning speed: 0.01 ~ 100 degree/min, max scanning speed: 500deg/min, sollar slit(incident & receiving): 2.5 deg, incident height limiting slit(dhl): open (10mm), necessary software and hardware for diagnostics capable of checking the equipment parameters/ calibration etc.divergent slit:variable to keep the x-ray illumination of sample same from low angle to high angle of 2 theta. detector:high speed silicon strip detector, it should work in 1d mode. also fluorescence reduction mode should be available. cu efficiency 99% samples holder: glass (0.2mm) qty 20, glass(0.5mm)-qty -20, aluminum (20 mmx20 mm) hole - qty 20, low background si sample holder- qty 02software: guidance based software system software should have a provision for the following: 1) all active operations should be controllable through the software 2)simultaneous data collection and data processing facility. facilities for peak search, peak match, and pattern treatment such as data smoothing, background subtraction, 2 correction, 3d multiple pattern display, k 2 calculation and removal, integrated intensity calculation, relative intensity ratio (rir) quantitative analysis and crystallite size. xrd-rietveld analysis. hybrid search / match algorithms which combines the features of peak based and profile based, phase identification techniques. it offers improves, qualitative analysis performance which makes, identification of crystalline phase with preferred, orientation or a complex lattice deformation.computer systems:latest pc along with latest operating system (latest 8.1 or 10), laser colour printer, necessary software for operation and data acquisition, analysiscod-data base:software is compatible with cod (crystallography open database) which is available on internet. (internal /external ) chiller:suitable compact for smooth running of xrd ups: online 6kva with 30 mts. backup.installation and commissioning: the instrument to be installed tested and commissioned by representative of supplier at our premises to the satisfaction of user free of cost.training: the supplier should provide the training on site free of cost.safety:the system should be housed in a high safety standard radiation enclosure as per international norms.warranty: at least one year from the date of installation(the supplier should provide the certificate of successful installation of benchtop xrd from the head of the department of concerned government labs/ institutes. )
Tender For armo of electrical and mechanical services for (access control, cctv, pa system, hvac, split ac, water cooler) at regional passport office building, bkc, mumbai. (2024-2025). sh-1) comprehensive maintenance of 3 nos. 140 tr water cooled chiller. 2) comprehensive maintenance of low side equipment of water cooled hvac system i/c electrical control panel and operation of air conditioning, ventilation system. 3) comprehensive maintenance of split a/c units, vrf, water coolers.subwork/packages:1) comprehensive maintenance of 3 nos. 140 tr water cooled chiller. 2) comprehensive maintenance of low side equipment of water cooled hvac system i/c electrical control panel and operation of air conditioning, ventilation system. 3) comprehensive maintenance of split ac units, vrf, water coolers.