Get complete information related to latest Chlorination Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Chlorination Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Chlorination Pump Tenders.
Tender For overhauling repairs to water turbine driven horizontal pumping unit at achoora gurez of misd hajin. - overhauling/major mechanical repairs/replacements of damaged non-functional mini water driven turbine (damaged by heavy snow slide) coupled with 03 cusec horizontal pumping unit. the job comprises of following works: pump sidei. engaging of labours in the machine drive chamber by way of moving of boulders and other trash till the machine chamber be cleaned and washed., ii. temporary oiling the turbine and pumping unit on machine chamber side till the the mechanism of machinery is free from rust and dust, then decoupling the pumping unit from the turbine coupling and genset from belting. using skilled labour and other tools and tackles., iii. dismantling of 8 x8 horizontal pumping unit from its existing pump foundation to machine floor smoothly without any hammer stroke using skilled job knowing personnel., iv. dismantling of the pumping unit parts at machine floor,removing of defective rotating kit assembly from the pump body using proper tools to be arranged by firm., v. shifting of the dismantled kit assembly with the allied accessories and defective chain pulley block to road side upto the lead of 150 m by head loading and then loading the rotating kit assembly in private load carrier to be arranged by the firm and shifting to workshop for conducting necessary repairs., vi. complete servicing of rotating kit cum bearing housing at workshop using diesel oil till the whole bearing assembly and rotating parts are washed and cleaned and free from rust and dirt. the job includes dismantling of bearing housing and removing of defective parts like damaged shaft, broken bearings and other items smoothly. the job includes removing of broken bolts from the bearing housing, re-tapping the damaged holes and providing and fitting of new holes., vii. repairs to impeller shaft of the pump by way of rebuilding the damaged portion using arc welding and then machining, polishing, threading completely till the size of the shaft is brought to required specifications. the job further includes providing and fitting of check nut as per sample., viii. manufacturing/providing and fitting of gm bush to suction part and gm cooling ring, gm gland with bolts. the job includes casting, machining, finishing to proper dimensions., ix. providing and fitting of high pressure gasket on suction side and delivery side., providing and fitting of ht bolts of assorted size, xi. rebuilding the wearing ring seats of suction and coupling end plates using ci welding electrodes. the job includes machining and finishing to proper dimensions., xii. repairs to defaced/ damaged impeller shoulder ring seats using ci welding electrodes. . the job includes machining and finishing to proper dimensions., providing and fitting of taper roller bearing on coupling side and gland side. the job includes greasing of bearing xiv. 32315, xv. 32314, xvi. assembling of bearing housing with rotating kit at workshop to check the rotating kit assembly is free from any obstacles and loading and shifting to site in private load carrier to be arranged by the firm including haltage and retun back of workers, turbine side:- repairs to turbine side by way of:complete cleaning and washing of turbine chamber by way of removing of boulders and other trash from the turbine by engaging of labours.complete servicing/ washing/oiling of turbine assembly in turbine chamber till the assembly of turbine and guide vanes are free from the rust and dust and then complete oil washing the guide vanes, guide hinges and outer body of turbineproviding and fitting if turbine shaft gm bush bearingtesting of turbine assembly on no-load decoupled from pump assembly by way of charging of turbine chamber to check the vibration, sound, rpm, setting of turbine guide vanes, hinges to ensure smooth functionre-installation of pumping unit by way of fitting of rotating kit assemblycomplete painting by black japan to entire pu
Tender For operation and guarding arrangement of high lift and gaseous chlorinationpumping machineries, indoor and outdoor illumination at water treatment plant under surface water based piped water supply scheme under panskura -ii block under midnapore mechan
Tender For corrigendum : supply of digital radiography system type c (qty:10) - digital radiography system 50kw ceiling suspended type, single detector with all accessories as per specifications except the following, x-ray table 6 way floating table, dry imager with 2 online trays, additional detector (rate fixed for three years from the date of price bid opening), light weight lead apron with thyroid gaurd, additional workstation, x-ray trolley table (not taken for evaluation), x-ray table four way (not taken for evaluation), x-ray view box double film (not taken for evaluation), cost of one viewing station (hardware) with necessary software and ups (not taken for evaluation), fully automated full length image stitching on table and vertical bucky necessary hardware and software (not taken for evaluation), 15.12.2:dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:of area beyond 3 sq. metres, 15.12.1:dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:of area 3 sq. metres and below, 15.23.1:dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.for thickness of tiles 10 mm to 25 mm, 15.3:demolishing r.c.c. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of engineer -in-charge., 15.57:dismantling aluminium / gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by engineer - in-charge, 15.7.4:demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge.in cement mortar, 15.60:disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved, 2.1.1:earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:all kinds of soil, 50.2.25.1:filling with contractors own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site engineer-in-charge, 2.34.1:supplying chemical emulsion in sealed containers including delivery as specified.chlorpyriphos / lindane emulsifiable concentrate of 20%, 2.35.1.1:diluting and injecting chemical emulsion for post -constructional anti-termite treatment (excluding the cost of chemical emulsion):along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:with chlorpyriphos /lindane e.c. 20% with 1% concentration, 50.4.1.1:providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc., 50.5.33.2:providing and laying in position machine batched and machine mixed design mix m-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the
Tender For corrigendum : supply of digital radiography system type b (qty:10) - digital radiography system 80kw ceiling suspended type, single detector with all accessories as per specifications except the following, x-ray table 6 way floating table, dry imager with 2 online trays, additional detector (rate fixed for three years from the date of price bid opening), light weight lead apron with thyroid gaurd, additional workstation, x-ray trolley table (not taken for evaluation), x-ray table four way (not taken for evaluation), x-ray view box double film (not taken for evaluation), cost of one viewing station (hardware) with necessary software and ups (not taken for evaluation), fully automated full length image stitching on table and vertical bucky necessary hardware and software (not taken for evaluation), 15.12.2:dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:of area beyond 3 sq. metres, 15.12.1:dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:of area 3 sq. metres and below, 15.23.1:dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.for thickness of tiles 10 mm to 25 mm, 15.3:demolishing r.c.c. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of engineer -in-charge., 15.57:dismantling aluminium / gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by engineer - in-charge, 15.7.4:demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer-in-charge.in cement mortar, 15.60:disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved, 2.1.1:earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:all kinds of soil, 50.2.25.1:filling with contractors own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site engineer-in-charge, 2.34.1:supplying chemical emulsion in sealed containers including delivery as specified.chlorpyriphos / lindane emulsifiable concentrate of 20%, 2.35.1.1:diluting and injecting chemical emulsion for post -constructional anti-termite treatment (excluding the cost of chemical emulsion):along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete:with chlorpyriphos /lindane e.c. 20% with 1% concentration, 50.4.1.1:providing and laying in position cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size) up to floor five level excluding the cost of centering, shuttering, finishing for leveling coarse of floor and roof etc., 50.5.33.2:providing and laying in position machine batched and machine mixed design mix m-20 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the