Get complete information related to latest Cinder Track Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cinder Track Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cinder Track Tenders.
Tender For corrigendum : in this estimate the raising work of existing ground level to the road level,cc block paving, maintenance work of well and proposal of compound grill etc are proposed.
Tender For annual civil maintenance work at turamdih mines - earthwork in excavation in the following types of soil and rock up to and including 1.5 mtr. lead including bailing or pumping out any water accumulating inside the excavated pit or trench shoring strutting adequate protection to be taken during excavation transporting the excavated soil for all lead stacking selectively including disposing off the rubbish rock fragments excess spoils etc. lead upto 100 mtrs. in the area as directed by the engineer all complete as per drawing specification and direction of the engineer. earth work in back filling with available earth including watering and compaction at all elevations around foundations walls wells tunnels pitsculverts trenches road approaches and in plinth filling and area filling as per specifications and drawings and as directed by the engineer with selected spoil within a lead of 100 mtr. disposal carriage of rubbish waste rock earth etc.dumped stacked at site by mechanical means including loading unloading and dressing properly lead upto 5 km. and up to any lift includind cost of all labours and equipments. surface dressing of the ground in all kinds of soil including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead up to 50 m and lift up to 1.5 m. supply mix place in position compact cure cement concrete 1 cement 3 coarse sand 6 graded stone aggregate 20 mm nominal size below foundations walls wells pits trenches etc. and in basin lining as per specifications drawings and directions of the engineer and including cost of centring and shuttering but excluding cost of cement. supply mix place in position compact and cure including testing of concrete specimens finishing surfaces as per specifications drawings and directions of the engineer of the following grades of concrete with 20mm and down graded stone aggregate and coarse sand in super structure or any level excluding cost of centring and shuttering cement and reinforcement. m20 rcc pcc taking delivery from store or departmental yard bend bind and place the following types of reinforcement in all types of reinforced concrete work at all elevations including cleaning straightening cutting bending and binding with 18 swg annealed wire or with welding such as tack lap butt etc with approved electrodes providing concrete cover blocks pin chairsnails supports of reinforcement etc. with all materials and labour complete as per drawings specifications and directions of engineer excluding cost of reinforcement. install dismantle and remove the form work of approved quality including splay recess corners haunch etc. scaffolding necessary rendering of concrete surfaces after exposure including cost of all material and labours at all elevations. supply and laying in position brick work with designate 75 bricks in super structure etc in cement coarse sand mortar 1 isto 6 including mixing mortar laying bricks raking joints curing etc complete with all materials and labour as per drawings and specifications excluding cost of cement. providing and fixing 125 into 63 mm m. s. hinges of approved quality and make. providing and fixing isi marked anodised aluminium tower bolt black finish barrel type with necessary screws etc. complete 300 into 10 mm providing and fixing isi marked anodised aluminium tower bolt black finish barrel type with necessary screws etc. complete 150 into10 mm providing and fixing bright finished brass hanging type floor door stopper with necessary screws etc. complete. providing and fixing aluminium extruded section body tubular type universal hydraulic door closer having brand logo with is 3564 embossed on the body door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm with double speed adjustment with necessary accessories and screws etc. complete. providing and fixing aluminium handles isi marked anodised anodic coating not less than grade ac 10 as per is 1868 transparent or dyed to required colour or sh
Tender For design installation and maintenance of educational lab - vocational lab; site preparation; buyer -1. provision of water supply, drainage pipeline for chemistry lab "the scope of work includes the design, supply, and installation of a 3/4 water supply pvc pipeline and a 2 drainage pvc pipeline for the chemistry lab, with both pipelines to be laid below floor level in accordance with the relevant standards. the water supply pipeline will be installed to deliver water to six wash basins located at lab tables, with all necessary piping, fittings, valves, and accessories provided to ensure proper water flow and functionality. the drainage pipeline will be installed for the safe removal of liquids from the wash basins, connecting to the existing drain system in compliance with local plumbing codes. the contractor is responsible for providing and installing all required pipes, fittings, junctions, seals, and ensuring proper slope for the drainage system to ensure it functions without leakage or obstruction. upon completion, the installed systems will be tested for functionality, and the floor will be leveled and prepared for tiling, with tiles installed in accordance with the specified quality standards and design. all materials used must conform to the relevant industry standards for durability and safety." 01 job, 2. installation of taps in chemistry lab wash basins "supply and installation of 2 taps per wash basin, located at each of the lab tables 06 nos. in the chemistry lab. the work includes ensuring correct connections, installation of necessary pipework, and verifying water-tightness and functionality of the taps. all components must be of high quality and suitable for laboratory conditions, ensuring ease of use and long-term durability." 01 job, 3. installation of exhaust fan system for chemistry laboratory "supply and installation of an exhaust fan system within the chemistry laboratory to ensure proper ventilation, facilitate the removal of hazardous fumes, and maintain a safe working environment. this installation shall include secure mounting, electrical wiring, a variable speed controller, and protective grills with all necessary arrangements, equipment and accessories." 02 job 4. provision of 3-phase electrical supply for strength of materials/ engineering mechanics lab "provision and installation of a 3-phase electrical supply from the existing mcb board to the strength of materials/ engineering mechanics lab located on the ground floor. this includes the installation of all necessary electrical cabling (4 sqmm /6 sqmm), 63 amp. 2 nos. & 32 amp. 4 nos., 4 pole individual mcb with box, connectors, and circuit protection devices, ensuring compliance with relevant electrical safety standards. the installation must be capable of supporting the lab's power requirements while maintaining optimal operational efficiency." 06 job 5. construction of foundations for thermal lab equipment "design and construction of reinforced concrete foundations to support 2 units of lab equipment (approximate measurements in meters (0.95 x 0.45 x 0.3) and (1.0 x 0.6 x 0.2)) in the thermal lab on the first floor. the specifications of work may evolve during the course of the project and foundations must be engineered to accommodate the weight and dynamic loads of the equipment while ensuring stability and long-term durability. all excavation, reinforcement, and concreting work must be carried out per the specified structural design, ensuring compliance with relevant building codes and safety regulations." 01 job 6. vibration damping foundations for thermal lab equipment "supply and installation of specialized vibration damping foundations (approximate measurement in meters (1.6 x 0.85 x 0.3)) for the morse test lab equipment in the thermal lab located on the first floor. the specifications of work may evolve during the course of the project and these foundations must be engineered to effectively mitigate vibration and noise caused by the o
Tender For consultancy offer (up to tendering stage) for the work of supply, installation, testing and commissioning of 10mw (ac) ground mounted grid connected solar photovoltaicpower plants with land on lease at any location in gujarat withcomprehensive maintenance up to 10 years including freemaintenance during first year.
Tender For repairing and maintenance of 20 ns. old shops of phool mandi, overhead water tank, repairing of toilet ground floor multipurpose hall and interlocking work behind the pushp mandi at apna bazar gomti nagar lucknow.
Tender For supply of preservation / maintenance of etsr stores: panel baily bridge - removing the under mentioned quantity of stores from the area of installation/stacking and layout the same on ground/work site area at ge 574 engr park.
Tender For providing composite work (mechanized/automated and manual cleaning,housekeeping, pest control, security, repair and maintenance of ac and ac plant, ro and water cooler, lift, dg set, solar panels, fire fighting system, parking management, operationalization and management of gym & swimming pool, maintenance of garden and cricket ground, minor civil & electrical repair and maintenance work) at sms medical college, jaipur, rajasthan.
Tender For certain maintenance work under ge east jabalpur - m & l for painting carefully (by taking necessary shut down from respective sub-station) on steel tubular poles 9 m high from (above grnd 7.5rm) upto top of the pole, including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality aluminium paint after preparation of surface by wire brush and painting with two coats of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing pole no. of suitable size of letters as directed. note : size of lettering and colours of paints will be directed by engr-in-charge., m & l for painting carefully (by taking necessary shut down from respective sub-station) on lt pcc pole 9 m high from (7.5 metre above natural ground ) upto top of the pole, applying two coats of cement base paint over a coat of alkalines resistant primer to surface of concrete pole with cement based paint after preparation of surfaces of poles including cross arms, bracings, clamps, cable protection pipes, street light clamps & pipe (fix to poles) with two coats of 1st quality of synthetic enamel paint, after preparation of surface with different colour code from ground level to 1.0 m high with writing pole no. of suitable size of letters as directed. note : size of lettering and colours of paints will be as directed by engr-in-charge., diasmantling of acsr or aac conductors of any size from lt poles or distrubution span of complete all as specified & directed., fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of aacsr/aac/lt over head conductors of any size with and including 14 swg binding wire and testing, complete all as specified & directed., m&l for acsr conductor lt (6 in 1) weasel type ,restringing and fixing it properly in between poles and connecteing it with insulator properly all as per required and directed by engg in chrge, dismantling gi wire of any size from lt poles or distribution span & removal from site, complete all as specified and directed., fixing only binding from disc/shackle/loop insulator etc and rebinding after tightening/restringing of galvanised steel wire 3.15 or 4 mm dia lt over head earth wire, complete all as specified & directed., m&l for over head galvanised steel wire 3.15 or 4mm dia on existing lt poles and stretching and then strengthening including binding & jointing the conductor and testing complete all as specified and directed., m & l for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with m.s. clamps, bolts and nuts of approved size, for lt, 20x15cm size complete all as specified and directed., dismantling old unserviceable insulators of any type including ms spindles, gi washers, nuts etc and s&f shackle type, porcelain, vitreous, white/brown or green insulator including galvanised mild steel straps(31x5mm), two gi washers & one gi nut, 100 mm height and 115 mm dia(max) suitable for working pressure 1100 volts grade, complete all as specified and directed., s&f pvc separator 2 way for lt overhead electric line complete all as specified and directed., s&f pvc separator 4 way for lt overhead electric line complete all as specified and directed., supply and fix, erection steel tubular swaged poles type 410 sp-31 (9 meter long), painting with two coat of aluminium paint over one coat of red oxide primer and marking pole nos with black sythetic enamelled paint including tarring one coat of steel surface embedded in concrete complete excluding earth work and pcc work and taking out old unserviceable lt pole complete all as specified and as directed., dismantling lt steel tubular poles and setting aside for re-use within 50 metres complete all as specified and directed.