Get complete information related to latest Clutch Wire Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Clutch Wire Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Clutch Wire Scrap Tenders.
Tender For supply of stud type terminal connector,end cover - elmex kps4 or equivalent,end clamp - elmex scusl or equivalent,barrier plate - elmex kbxf or equivalent
Tender For supply of terminal connector on la to suit 2 acsr moose c1 , terminal connector on bpi to suit 4.5 ips al tube c5 , terminal connector expansion type on cb to suit 4.5 ips al tube , terminal connector expansion type horizontal take off on iso to suit 4.5 ips al tube c2 , terminal connector horizontal take off on iso to suit 2 htls conductor c2 , terminal connector rigid type horizontal take off on iso to suit 4.5 ips al tube c2 , terminal connector expansion type on ct 3000a to suit 4.5 ips al tube c3 , terminal connector on ct 3000a to suit 2htls conductor c3 , terminal connector on cvt to suit 2acsr moose c4 , terminal connector on emvt to suit 2htls conductor c5 , terminal connector expansion type on cb to suit 4.5 ips al tube c6 , terminal connector on wave trap to suit 2 htls conductor c7 , terminal connector on bpi to suit 2acsr moose c8 , tee clamp to suit 2htls to 2 htls conductor t1 , tee clamp to suit 2htls to 4.5 ips al tube horizontal take off t2 , tee clamp to suit 2htls to 2acsr moose conductor t3 , pg clamp to suit 2acsr moose to 2acsr moose conductor t4 , t clamp for inverted v connector to suit 4.5 ips al tube t2
Tender For supply of expansion type terminal connector to suit 50 dia aluminium tubular bus-bar to terminal pad of 25 kv isolator/ct/cb (ri no. /part no. 11061, 11062, 11063) with fasteners, as per rdso specification ti/ spc/ohe/fitting/0130-10/13-rev-1 & drawing no. eti/psi/p/11060, rev.e or latest. make/brand - core ap proved vendors only. (list attached) [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras supply of 3000010646_ 1_ 83002101160-loopin loopout box-ltg pole junction box loop in loop out junction box as per attached technical specificationwith following minimum requirement. frp material of thickness 4mm (min),04 no of ways(min)at bottomwith provisionof cable gland,08 nos(min) terminal connector of1100v grade and supporting cable size:25 sqmm max) (one) and 03nos of 4cx2.5sqmm copper cable.dimension of jb (wxhxd)mm:150x150x75mm. (minimum)overall dimension tolerance ( +in mm): 20 in w xh and 10 in dmaterial of junction box: fibre reinforced plasticdegree of protection: ip65 (as per is/iec 60529:2001 latest)safety compliances: fire retardant and self extinguishing ul-94 5vamaterial (sheet)minimum thickness (in mm): 4type of front cover fixing on junction box (front side): front cover with 4 nos. quarter turn tool operated locking knobs.provision of knock out for cable glands on junction box: yesno. of ways on jb: 4 (bottom side)shape of the jb: rectangular/squarevoltage grade of terminal block: 1100 v (min), 50 hz, ac number of terminal connector on junction box:8 terminal connector supporting for maximum size of conductor (in sq mm):4cx25sqmm al cable insulation resistance> 200 mohmtype of mounting: structural mounting/wall mounting accessories for each junction box: neoprene rubber gasket 1 no.high voltage withstand test (between all live parts connected together and the body):2 kv (rms) for 1 minute availability of test reports withcomplete drawings from central govt lab/nabl/ilacaccredited laboratory to prove conformity of the specification: yestest report number and date : party to furnishname and address of the lab: party to furnishagreed to furnish all the test reports and certificates to the buyer/consignee on demand: yes""all other specifications are as per annexure-1, party to submit theannexure -1 in complete filled up & signed condition failing whichthe offer will be technically rejected"
Tender For bid to ras corrigendum : supply of surge arresters and accessories - locations as mentioned in scope of work in annex-01 , 216 kv surge arrester for wr-i at various locations as mentioned in scope of work in annex-01 , 216 kv surge arrester for nr- ii at various locations as mentioned in scope of work in annex-01 , 216 kv surge arrester for sr-ii at various locations as mentioned in scope of work in annex-01 , 132 kv surge arrester for nr-i gr-1 at various locations as mentioned in scope of work in annex-01 , 132 kv surge arrester for nr-i gr-2 at various locations as mentioned in scope of work in annex-01 , 132 kv surge arrester for nr-iii at various locations as mentioned in scope of work in annex-01 , 132 kv surge arrester for wr-i at various locations as mentioned in scope of work in annex-01 , 132 kv surge arrester for kotra ps as mentioned in scope of work in annex-01 , 120 kv surge arrester for wr-i at various locations as mentioned in scope of work in annex-01 , 120 kv surge arrester for nr-iii at various locations as mentioned in scope of work in annex-01 , 120 kv surge arrester for nr-i gr-1 at various locations as mentioned in scope of work in annex-01 , 60 kv surge arrester for nr-i gr-2 at various locations as mentioned in scope of work in annex-01 , 624 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , 390 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , 336 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , 336 kv terminal connector for ner at various locations as mentioned in scope of work in annex-01 , 336 kv terminal connector for sr-ii at various locations as mentioned in scope of work in annex-01 , 336 kv terminal connector for wr-ii at various locations as mentioned in scope of work in annex-01 , 216 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , 216 kv terminal connector for ner at various locations as mentioned in scope of work in annex-01 , 216 kv terminal connector for sr-ii at various locations as mentioned in scope of work in annex-01 , 216 kv terminal connector for wr-ii at various locations as mentioned in scope of work in annex-01 , 132 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , 120 kv terminal connector for nr-iii at various locations as mentioned in scope of work in annex-01 , surge monitor for sr-ii at various locations as mentioned in scope of work in annex-01