Tender For corrigendum : work of repair replacement of pump of high pressure supply unit, inspection and servicing of instrument plant air compressor of model no. zr 250 and checking repairing of refrigeration type h2 drier of unit no 10 11 of stps, sarni
Tender For supply of laboratory and scientific equipment/tools - laboratory and scientific instruments/tools, compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r22, cooling capacity: 2355 kcal/hr type, voltage 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r134a, cooling capacity: 1411kcal/hr, voltage: 440vac, 25mfd, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type:r134a, cooling capacity: 0.25hp; supply voltage: 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., capillary tube : 1.12 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.20 mm od, 8 ft, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.40 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 0.95 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., thermostatic expansion valve: orifice- 0 no., connection-1/2 x 3/8 flare (details as per sl. no. 3 at annexure-i)., thermostatic expansion valve: ten 068z3348, q-33311 r134a -40 to 10 ps 34 bar. (details as per sl. no. 3 at annexure-i)., hand stop /manual shut-off valve: media: r22, r502, r134a, r407c, r410a; port size: 3/8" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., hand stop /manual shut-off valve: media: media: r22, r502, r134a, r407c, r410a; port size: 1/4" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., evaporator coil : 1/4" od, material: copper astm b280 (details as per sl. no. 5 at annexure-i)., condenser coil ; 3/8" od, material: copper astm b280 (details as per sl. no. 6 at annexure-i)., dimmer stat : 1500 w, 230 v ac. single phase, 50hz (details as per sl. no. 7 at annexure-i)., pressure gauge : connection 1/ npt 8 0 - 200 psi dial size 2.5" (63mm), connection sizes 1/4" (details as per sl. no. 8 at annexure-i)., digital temperature indicator : range -30 to 200 0c, power supply 230vac, digital display, accuracy 0.01 c channel -12 (details as per sl. no. 9 at annexure-i)., digital temperature indicator : type input cr-al(k-type), rang- 0 0c to 200 0c supply- 230vac, 50hz, channel -12 (details as per sl. no. 9 at annexure-i)., ammeter (digital) : rang 0-10 amp. single phase, digital display, 230v,10%vac (details as per sl. no. 10 at annexure-i)., voltmeter (digital) : rang 0 300-volt, single phase, digital display (details as per sl. no. 11 at annexure-i)., hp/lp cut out relay : hp- 8 to 32 bar, lp-0.2 to 7.5 bar, dual controls, 240 v, 50 va, single pole changeover switch (spdt), contact load 240 v ac: 8 fla, 48 lra (details as per sl. no. 12 at annexure-i)., energy meter : a.c. single phase, 2 wire solid state (static) fully electronic energy meter, accuracy class 1.0 & current rating 5-30 amp. with backlit lcd display for240 volt system fitted with pilfer proof meter box.(details as per sl. no. 13 at annexure-i)., r-134a refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; application: refrigerant; type of refrigerant-r134a. (details as per sl. no. 14 at annexure-i)., r-141b refrigerant gas : 5 kg filled cylinder; purity 99.9% appearance: colourless (details as per sl. no. 15 at annexure-a)., r502 refrigerant gas : 5 kg filled cylinder; acidity 0.00001 % appearance: colourless purity 99.9 % (details as per sl. no. 16 at annexure-i)., r407c refrigerant gas : 5 kg filled cylinder; appearance: colourless purity 99.9 % (details as per sl. no. 17 at annexure-i)., r-1234ze hfo refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; (det
Tender For supply of refrigeration rotary compressor hermetic type non inverter type split air conditioner capacity 1.5 tr , refrigeration rotary compressor hermetic type inverter type split air conditioner capacity 1.5 tr , outdoor unit with compressor non-inverter type spilt air conditioner of capacity 1.5 tr , outdoor unit with compressor suitable for inverter type spilt air conditioner of capacity 1.5 tr, , outdoor unit without compressor non-inverter type spilt air conditioner of capacity 1.5 tr , outdoor unit without compressor suitable for inverter type spilt air conditioner of capacity 1.5 tr, , indoor unit of split air conditioner of capacity 1.5 tr suitable for non-inverter split air conditioner, , indoor unit of split air conditioner of capacity 1.5 tr suitable for inverter split air conditioner,
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - manufacturing unit; overhauling calibration testing of servomotor assemblies of process air compressor and ammonia refrigeration compressor as per sow and quantum of jo..
Tender For supply and installation of air ammonia cooled reciprocating compressor with cutouts flywheel motor pulley stop valves unloading assembly with capacity control arrangement for refrigeration plant at mpf hyderabad
Tender For supply, installation, testing and commissioning of air cooled ammonia compressor of 136 tr cap without motor suitable for existing 215 hp siemens make motor with necessary civil and electrical works at refrigeration section, product dairy dharwad on turnkey basis