Get complete information related to latest Communication Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Communication Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Communication Cable Tenders.
Tender For supply of supply of air cooled split airconditioners please refer as per specification attached , installation charges for complete system please refer as per specification attached , supply installation of hard drawn copper refrigerant piping please refer as per specification attached , communicationcable of suitable rating, as per site requirement please refer as per specification attached , fabrication and installation of ms base frame for indoor units and outdoor units please refer as per specification attached , during commissioning please refer as per specification attached , providing and fixing copper armoured power cable please refer as per specification attached , cable tray gi perforated cable tray with cover for piping work please refer as per specification attached , supply fabrication installation and commissioning of ducting please refer as per specification attached , supply and fixing of nitrile rubber of thickness 13 mm or higher please refer as per specification attached please refer as per specification attached , suitable air eye ball jet diffuser with damper to supply air at least 12 nos or higher refer as per specification attached , suitable air eye ball jet diffuser with damper to supply air at least 12 nos or higher as per site requirement please refer as per specification attached , cpvc drain pipe with nitrile rubber insulation and all necessary fittings please refer as per specification attached
Tender For providing of custom bid for services - repairing of damaged optical fiber cablecommunicationcable of gouri pouni(a) ocm and pauni ii expansion ocm under gpsa ballarpur area
Tender For supply of 90 hp - 30 x 3 nos refer details as per specification , 60 hp - 30 x 2 nos refer details as per specification , 11 tr 1 circuit r410a or better refer details as per specification , odu joint as per site requirement refer details as per specification , refnuts as per site requirement refer details as per specification , installation and commissioning of the complete system as per site requirement refer details as per specification , copper pipes for idu as per site condition refer details as per specification , copper pipe from idu to odu of suitable size as per site requirement refer details as per specification , 1 inch cpvc drain pipe line along with all the required item as per site requirement refer details as per specification , cable tray for copper piping - 8 inches tray as per site requirement refer details as per specification , idu to odu communicationcable with conduit as per site requirement refer details as per specification , cpvc drain pipe - 4 inches for main line as per site requirement refer details as per specification , n2 pressure testing for all idu and odu vacmming and commissioning refer details as per specification , lifting of vrf ductable odu with crane refer details as per specification , weling work for gear shop area as per site condition refer details as per specification , ducting work as per site condition refer details as per specification , power socket near idu 32 amps socket - 4 sqmm cable with top and socket as per site condition refer details as per specification , supply and installation of power cable from panel board to mcp near odu as per site condition refer details as per specification , complete refrigant gas top up for the full system refer details as per specification , dismentling of old ductable idu and odu with duct grills refer details as per specification ) /bid number : gem/2026/b/7091891 * /dated: 09-01-2026 & & / bid document 1 / 23
Tender For corrigendum : supply of 10 hp vrf outdoor unit , 12 hp vrf outdoor unit , 14 hp vrf outdoor unit , 0.8 tr indoor unit , sitc of 1.0 tr indoor unit , sitc of 1.6tr indoor unit , sitc of 2.0 tr indoor unit , sitc of 2.6 tr indoor unit , sitc of 3.2 tr indoor unit , sitc of 4.0 tr indoor unit , sitc 4.6 tr indoor unit , supply installation testing and commissioning of wireless remote controller , sitc of following copper fittings to be provided in refrigerant pipe line t joint , sitc of following copper fittings to be provided in refrigerant pipe out door connection kit , supply of 1.9 tr inverter ttpe split ac with wireless remote , supply of 1.5 tr inverter ttpe split ac with wireless remote , copper pipe 41.3 mm , copper pipe 34.9 mm , copper pipe 28.6 mm , copper pipe 22.2 mm , copper pipe 19.1 mm , copper pipe 15.9 mm , coper pipe 12.7 mm , copper pipe 9.5 mm , copper pipe 6.4 mm , normal split copper pipe , pvc drain pipe 25mm dia , pvc drain pipe 32 mm dia , pvc drain pipe 40 mm dia , sitc of microprocessor based communicationcable , hot dipped gi perforated 20 guage tray 450mmx75mm x 1.6mm thickness , hot dipped gi perforated 20 guage tray 300 mmx75mm x 1.6mm thickness , hot dipped gi perforated 20 guage tray 200 mmx75mm x 1.6mm thickness , hot dipped gi perforated 20 guage tray 150 mmx75mm x 1.6mm thickness
Tender For enquiry notice for supply of digital mw indicator, digital kv indicator, digital ka indicator and rs485 communicationcable 1 pair shielded at hvdc t&t unit padgha under hvdc rs(o&m) circle, padgha.
Tender For tender for defect rectification in communication between relays and rtu by replacing damaged communicationcables and other allied works for compliance to the observations of protection audit report at 220 kv sub-station hpsebl nehrian.
Tender For supply of set of safety wire rope sling (for under slung compressor) consisting 02 items:- (i) wire rope sling of length of 3.0 m, dia 8.0 mm,6x19 with steel core as is: 2762:2009 and wire rope as per is: 2415:2004 gr 1770 n/mm square,qty-01 no. (ii) thimble suitable for 8mm (dia) wire rope as per drg. no. tata/rs/misc/1064. test certificate: sling should be tested by nth or any other govt approved test house. certifcate should be issued with sling