Tender For bid to ras supply of ac system of display hall c c -air diffusersorgrill with powder coated aluminium refer annexure iii , 100000000013 supply of return air diffusersorgrill with powder coated aluminium single piece refer annexure iii , 100000000014 supply of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iii , 100000000015 supply of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and spring return refer annexure iii , 100000000016 supply of control instruments and sensors required for combined fire and smoke damper including actuators refer annexure iii , 100000000017 supply of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volume control damper made of aluminium refer annexure iii , 100000000018 supply of floor mounted cubicle non drawout electrical control panel for operating 3 nos ductable unit and 1 no heater bank total 4 nos outgoing feeder refer annexure iii , 100000000019 supply of following size lt power cable with copper conductor xlpeorpvc insulation pvc inner sheathed armoured extruded pvc outer sheathed refer annexure iii , 100000000020 supply of xlpe insulated pvc sheathed armoured copper conductor 2xfy, 1. 1 kv grade lt cable of size 4. 0 core - 2. 5 sqmm refer annexure iii , 100000000021 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1. 6 mm thickness refer annexure iii , 100000000022 installation testing and commissioning of high static pressure ductable ac unit capacity not less than 16. 5 tr having one indoor and refer annexure iv , 100000000023 erection testing and commissioning of high wall mount type hot and cold split ac units of cooling capacity not less than 2. 0 tr minimum 3 star rating inverter refer annexure iv , 100000000024 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac refer annexure iv , 100000000025 erection, testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of split ac refer annexure iv , 100000000026 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling refer annexure iv , 100000000027 laying of cpvc sdr11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000028 laying of cpvc sdr11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000029 fabrication installation testing and commissioning of site fabricated gi sheet metal ducts of 24 guage birmingham gauge refer annexure iv , 100000000030 fabrication, installation, testing and commissioning of site fabricated gi sheet metal ducts of 22 guage birmingham gauge refer annexure iv , 100000000031 fixing of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric nitrile rubber class o refer annexure iv , 100000000032 fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure iv , 100000000033 erection testing and commissioning of volume control dampers for ducts made of gi sheet of thickness not less than 18 g including fittings refer annexure iv , 100000000034 fixing, testing and commissioning of supply air diffusersorgrill with powder coated aluminium single piece moulded frame refer //bid details2 / 31annexure iv , 100000000035 fxing, testing and commissioning of return air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure iv , 100000000036 erection testing and commissioning of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iv , 100000000037 fxing testing and commissioning o
Tender For tender description : s r of e i and fans in dr brairch at aiims new delhi sh replacement of existing 3 nos single phase 10kva ups with 2nos new 40kva ups along with cubicle panel incoming and outgoing cable from 6th floor riser room to new ups panel sh a ups work sh b electrical work
Tender For supply of supply and installation of partitions and work station for cubicle work station of size 3000 multiply 3000 multiply 1200 mm as per technical specifications and drawing no 01 , supply and installation of partitions and work station for cubicle work station of size 2530 multiply 3275 multiply 1200 mm as per technical specifications and drawing no 02 , supply of high back revolving chair as per technical specification , supply of medium back revolving chair as per technical specification , supply of side credenza of size 1000 multiply 450 multiply 700 mm , supply of mobile drawer pedestal of size 850 multiply 400 multiply 685 mm , dismantling and shifting of existing cabins
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - onboard ins kalvari at nd(mbi); electrical system or installation, 72m routine maintenance of epm, converter cubicle and dgs onboard ins kalvari; service provider
Tender For corrigendum : supply of service 11 kv ht panel , sf new mineral oil for panel etc , filteration of mineral oil , servicing of existing mv panel , check and rectification of em interlock , calibration relay etc , sf silicagel , sf 32a hrc fuselink , sf 63a hrc fuselink , sf 125a hrc fuselink , sf 250a hrc fuselink , sf led indication lampa 220v ac , sf 0 to 400a ac ammeter digital , sf 0 to 500a ac voltmeter digital , sf 0 to 30 a dc ammeter digital , sf slelector switch vlotage or current , sf operationg handles for sfu cubicle for extg panel , carryout servicing of 500kva ea set as per specification b chck , repair and service of radiator for 500kva ea set , attending air circuit breaker 800a gec make as reqd , servicing of air circuit breaker 800a gec make as reqd , sf 12v 180ah low mtce battery for ea set , sitc 5 kvar app capacitor , sitc 10 kvar app capacitor , sitc 15 kvar app capacitor , sf 6 stage auto power factor corrector reelay in extg panel , sf 400a mccb with handle on off lamp in sheet steel enclosure
Tender For srm e-enquiry for supply of two numbers of 415v lt distribution panel with changeover switch for ict 1 and ict 2 fan cubicle ac distribution at 400kv rs karad
Tender For auction sale of depot non ferrous scrap - cond & u/s stainless steel scraps such as pipes/ sheets, hot boxes, bins,flasks,stay bolts,trough sheets ,ss clip assembly,flasks,distilled water plant,three seaters,stainless steel geyser,stainless steel feeder junction box,hand rails, dust bins,stainless steel under frame box,distilled water plant,steel tiffin carrier container,dressing drums,ss rope,plates, cups,forks,food warmer,stainless steel bolts,hand rails, toilet base,tea cans,filters,canvasses,jars, trays,jugs,plates, jugs,wall protectors, wash basins , clip assembly stainless steel,storage box,mixie jar, landing door ,vessels,owens,tumblers, strips, lavatory pan in lay,berth utility wire rods,ss bolts,bearings,filters of various types & sorts ,hot cas,sterlisers,leggings,liquid receiver,mortise lock 8 lever,kettle, under slung water tanks of various sorts& sizes,commode adapter, stainless steel vessels including tea cans,the items include ss rbc enclosure box, access door for bfm of sg coaches, hot water boiler, probe holder clamp (non-gauge face) for srt/drt, extension pin for toggle clamp for srt09 channel machines, feeder junction box, stainless steel water tank, stainless steel 6.5 kw rbc cubicle, stainless steel clip assembly, stainless steel (miscellaneous), stainless steel water tank assembly, and ocb filter assembly along with ss pipe and ss sheet,bio toilet ball valves with/ without available attachments and all other stainless steel scrap nature items including magnetic steel items, trough sheets and the above lot is with ferrous attachments,steel/stainless steel pipes/light fittings /filters with/without ferrous fittings /attachments/magnetic steel attachments /adherings, in full/part/broken and in loose parts. note: 1) removal of ferrous/glass/rubber /thread mesh/ wood and other attachments etc are not permitted. 2) cutting is not permitted 3) if any extraneous material/material of aluminium in nature found in the lot, the same should be handed over to the custodian at the time of delivery. pl no 98090719