Web Analytics Made Easy - StatCounter

Computerized Seed Counter Tenders

Get complete information related to latest Computerized Seed Counter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Computerized Seed Counter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Computerized Seed Counter Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :39104867 Due date: 17 Feb, 202517 Feb, 2025 NA
Tender For science lab and geography lab items - lab items, ammeter dc to ac, analog multimeter, andersonand schering andhay and kelvin and maxwell and de sauty and wiens bridges, apparatus for measurement of capacitance and inductance using impedance at different frequency, apparatus for studying diffraction from reflection grating model, apparatus to determine the rydbergs constant with the help of diffraction grating and hydrogen discharge tube. complete with high voltage power supply, grating and spectrometer., apparatus to determine the temp coeff. of resistance of platinum complete with all accessories., apparatus to determine the viscosity of fluid using poiseuileas method, apparatus to draw b-h curve of ferromagnetic material with the help of cro, apparatus to study tunnel diode, apparatus to study charging and discharging of a capacitor., apparatus to study response curve for lcr circuits and to determine the resonance frequency., apparatus to study specific resistance and energy gap of a semiconductor., apparatus to study the absorption spectra of iodine vapour complete with white light source. power supply. grating, and spectrometer., apparatus to study transistorised regulated power supply., apparatus to verify newtons law of cooling, audio frequency generator, babinet compensator with optical bench and accessories, ballistic galvanometer with lamp and scale arrangement, bending of beam apparatus to determine youngs modulus, biprism assembly, biquartz or half shade polari meter, value of mechanical apparatus to determine the calendar and barnets equivalent of heat, c.r.o. dual trace 20 mhz, c.r.o. dual trace 40 mhz, cantilever to determine youngs modulus, choke of mercury lamp, complete apparatus for study of zeeman effect with all accessories for determination of lande-g- factor, complete apparatus to determine resolving power of telescope, complete apparatus to determine the heating efficiency of electrical kettle with various voltages, complete apparatus to verify law of parallel and perpendicular axes for moment of inertia, complete apparatuse to determine e/m by milikans method, complete setup to find the wavelength of sodium light with the help of fresnels biprism., compound pendulum/bar pendulum, compton effect experiment, cro single trace 20 mhz, characteristic apparatus dielectric constant, digital multi meter, drill machine with all size bits, e/m by helical method, digital storage oscilloscope 40 mhz, f.e.t. amplifier, four probe method, frank hertz experiment, fresnel biprism diffraction apparatus model, function generator 0.3 to 3 mh, function generator hz to 10 mhz, half wave and full wave rectifier apparatus with built in power supply, hall probe method for measurement of resistivity. complete with hall effect setup, hall probes, digital gauss meter, electromagnet and constant current supply., hartley and colpitts oscillator, horizontal torsion apparatus, hybrid solar and wind energy trainer., hydrogen spectra balmer series apparatus, impedance and power factor of lcr circuit, induction hot plate with induction pots, jaegers apparatus to determine the surface tension, laser raman spectrometer(ccd based), lees disc, m.o.s.f.e.t characteristic apparatus, magnetostriction with michelson interferometer model c" ho-ed-int- 06m, measurement of low resistance by carey foster s bridge complete with power supply., measurement of thickness of thin wire with laser complete setup, measurement of wave length of he-ne laser using ruler with laser complete setup, mercury lamp, newtons rings apparatus complete with travelling microscope, power supply and sodium lamp., photo diode characteristic apparatus, photo transistor characteristic apparatus, photoconductivity experiments, physical balance, plancks constant using solar cell, plug key one way/two way, scarles apparatus to determine the coefficient of thermal conductivity, series and parallel resonance circuit, single slit diffraction and heisenbergs uncertainity, slotted w

CTN :38940732 Due date: 03 Feb, 202503 Feb, 2025 58.00 Lacs
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - rota-evaporator the rota-vapour should have a vertical condenser for standard applications with cooling surface area of 1500 cm2 or better with a protection class of ip20 or better. the rotation speed of the instrument should be 20-280 rpm or better. the water bath should have controlled temperature range of heating within a range of 0-90oc or better with a capacity to accommodate evaporating flask from 50-4000 ml with same joint. all glass components should be made of borosilicate 3.3 glass. digital interface of 4 inches or better to facilitate monitoring of temperature, speed and vaccum. there should be a provision of power cut off when actual temperature exceeds set temperature or by rapid temperature increase. the system should have timer function to regulate the time of the process and automatic aeration when pressure reaches above 1400 mbar. the entire system should have ce/csa approvals. the vaccum pump should be made up of chemically resistant ptfe diaphragm vacuum pump with a suction capacity of 1.5m3/h or better with 2(2) number of steps(heads). the final vaccum should be 7-10 mbar. the recirculating chiller should be of 3l capacity with a working temperature range of room temperature to -10oc and a cooling capacity of 500 w at 15oc., ft-irthe ftir instrument should have transmission interface which provides classic infrared sampling for the measurement of solids, liquids or gases. the transmission module is purgeable and preferable to come with a standard cardholder. the scan range should be from 8000-350 cm-1 with a spectral resolution of 0.5cm-1 or better. the signal to noise ratio: 35000:1 or better. the system should have michelson type/ rock solid/self-compensating, dynamically aligned interferometer which removes any tilt and shear scanning error with 10 years warranty on interferometer. the system should have temperature stabilized or dtgs detector/ temperature control dlatgs detector. kbr/ znse beam splitter to meet complete spectral range. the system should be operable through a windows 10 compatible software with self-diagnostic after initialization, provision for creation of library. the software should have spectral, peak and text search function. the software should be capable of comparing spectrum, quantification and photometric data. there should be a provision of digital humidity level monitoring in internal optics through software and customized template. the system should be supplied with following accessories.hydraulic press for kbr pellet preparation software recognize diamond atr accessory with force monitoring for quick analysis of different sample) solid, liquid, paste and gels) of food, raw material, packaging material etc.installation, familiarization at installationpccorei5, 4gb ram, 1 tb hdd, 18.5 led/lcd, windows 10 , uv visible spectrometer microprocessor based wavelength range: 190 to 1100 nm with 7-8 inch led display. the system must have pre-programmed methods for water parameters which should be compatible with available reagents for the water testing. system should be true double beam uv-visible spectrophotometer with 8-cell changer the monochromator should be blazed czerny-turner type with 1200 lines/nm blazed grating. the detector should have si-diodes/ccd. system should have wavelength range from 190 to 1100 nm or better system spectral bandwidth should be 1 nm (190 to 1100 nm) wavelength setting should be 0.05 nm wavelength accuracy should be 0.3 nm wavelength repeatability should be 0.1 nm or better scan speed max 6,000 nm/min or better photometric range absorbance : -4 to 4 abs transmittance range should be : 0 % to 400 % photometric accuracy should be less than 0.005 abs at 1.0 abs light source tungsten halogen lamp & deuterium lamp photometric repeatability 0.0002 at 0.5 abs baseline stability: 0.0003 abs/h operating system (os): system should have to

Central Government/Public Sector

CTN :38917672 Due date: 31 Jan, 202531 Jan, 2025 50.00 Lacs
Tender For e-tender for purchase of lab equipments/apparatus - lab equipments/apparatus, steel ball (3kg) 20 cm diameter, steel chain 5 meter and 1cm diameter, newton s ring apparatus, michelson interferometer, fresnel biprism, optical bench kit, radio active sources kit (brit/barc)1. gamma source kit - 4nos2. beta source kit - 4 nos, hall probes and sample, four probes and sample(temperature upto 300 c), curie temp kit, ics for electronics (2input) ic number 1 - 7408, ics for electronics (2input) ic number 2 - 7400, ics for electronics (2input) ic number 3 7402, ics for electronics (2input) ic number 4 7432, ics for electronics (2input) ic number 5 7486, ics for electronics (2input) ic numbe 6 - 7404, ics for electronics (2input) ic numbe 7 - 747266, cutting pliers and wire cutters, quinckes tube, lattice dynamics kit, dielectric constant kit, scientific tuning forks kit , frequency 256 to 512 hz, with hammer & wooden case, cro cables bnc to bnc, magnetic plotting compass, deflection magnetometer, rectangular post office box for resistance measurement, diffraction grating, glass prism, nand gates (ic 7400 (2 o/p), nor gates (ic 7402 (2 o/p), not gates (ic 7404), and gates (ic 7408), or gates (ic 7432), leds (5mm with any colour), fecl3, cathode ray tube, b.g. lamp & scale arrangement, plancks constant setup, photodiode characteristics setup, polarimeter - sugar, multi strand copper wire, with different coating colours(black,red,green,yellow), angle measurement protractor 0 to 180 degree, steel wire, 5 mm diameter, bundle 100 m, tungsten filament lamp, lamp or bulb-is:418, 60 w, incandescent bulb 100w, high pressure mercury vapour lamps (hpmv lamps), 400 watt, male dual alligator clips for oscilloscope, stefan constant kit, 400 w high pressure sodium vapour lamps (hpsv lamps), meter bridge, solar cell kit, microscope(with digital screen led screen display), herbarium press, digital microscope fluorescence laboratory microscope with pc and hd camera, electronic balance - readability 324g, accuracy-0.0001repeatability 0.0001, main body dimension 213wx356dx338h mm, pan-91mm, molecular model kit-standard - large, lightweight molecular models for classroom demonstration of organic and inorganic structures. for building models to scale of 20 cm/ and 8 cm/ . bond lengths range from 5.5 to 27 cm. atomic centers are 5 cm in diameter, finished in standard atom colors, and have a reinforced vinyl receptor at each bond position for insertion of connecting rods (bonds)., potentiometer - 4 electrodes for different titrations resolution:0.1 mvdigital led displayaccessories electrode:pt-electrodeglass electrodesilver electrode range 2v to 2vmagnetic stirrer in built, conductometer - 5 ranges0.0-20.0 s/cm ;20-200 s/cm200-2000 s/cm;2-20ms/cm20-200 ms/cmresolution 1.01 s/cmoscillator 1kh2 inbuiltcell constant 0.2-1.41accessory electrode- conductivity electrodemagnetic stirrer in-built, fume hood - velocity control of approximately 80-100 feet per minute. semi close ventilated exposures. outer construction of thick pcrc, pre coated corrosion resistant gi sheet. inner construction of high grade ss-304 provided with sliding sash made out of special grade shatter proof glass duly framed in wooden/aluminum frame with sliding motion and counter weight balanced mechanism. illumination level of approx. 800 lux on the work table. heavy duty exhaust system, comprising of dynamically balanced centrifugal impeller with high speed motor suitable frp ducting of required dimension as per the individual requirements low noise level. energy efficient., digital oil bath with magnetic stirrer - stainless steel, sensor pt, temperature 300 c, high speed rotation 3l, digital oil bath with magnetic stirrer - oil bath 230 x 130 mm 3l, uv chamber - uv viewing cabinetcabinet with removable, combination uv light source (365nm/254nm); 4-watt tubes, lightweight aluminum minicabinet, long- and shortwave irradiation for viewing tlc plates, and for uv fluorescence or absorption,
 Loading, Please wait...

Connect us via What's Up