Get complete information related to latest Consultants Service Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Consultants Service Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Consultants Service Tenders.
Tender For supply of configuration of 43 inches led monitor with inbuilt soc on suitable ceiling mount brackets or frames etc , mounting, fixing, installation and configuration of 55 inches led monitor with inbuilt soc on suitable ceiling mount brackets or frames etc , installation and configuration of desktop pc with softwares at site , installation and configuration of server for primary pc with softwares at site , installation and configuration of server fail over for backup pc with softwares at site , installation of antivirus for server and desktop , mounting, fixing, installation and configuration of 24 ports l2 network switches , mounting, fixing, installation and configuration of 24 ports l3 network switches , mounting, fixing, installation and configuration of 8 ports l2 network switches , installation and fixing of sfp , mounting, fixing and dressing of 42u floor stand rack , mounting, fixing and dressing of 6u wall mount rack , digging, consuling etc. of 6 core outdoor armoured single mode ofc cable , mounting, fixing and dressing of fibre optic liu 12 port loaded with lc adapter , mounting, fixing and dressing of fibre optic liu 24 port loaded with lc adapter , mounting, fixing and dressing of fibre optic liu 6 port loaded with lc adapter , termination and fixing of lc lc , laying of cat6 utp through pvc pipe , mounting, fixing and installation of 24 port patch panel , termination and fixing of 1 mtr. cat 6 utp information outlet , termination and fixing of 2 mtr. cat 6 utp information outlet , termination and fixing of 5 mtr. cat 6 utp information outlet , installation of information outlet as per technical specification , mounting and installation of kvm and console , laying of 3 core 2.5 mm electrical cable through pvc pipe , installation of 16 amp three pin shuttered switch socket combined 3 in 1 with cover plate and back box , laying or fixing of 25 mm and 32 mm pvc pipes and flexible pipes on or above of false ceing or fixing on wall including fixing of suitable saddle or screws etc , installation of 25amp mcb with db box , testing, commissioning and integration of fids software , installation, testing and commissioning of 01 no. 15 kva ups for primary , installation, testing and commissioning of 01 no. 15 kva ups for backup , testing, commissioning, certification, providing 3 sets of completion diagram and documentation of entire project
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For "supply, installation, testing and commissioning of various passenger amenity items including bogie/ coach position indicator boards and main line indicator boards, coach guidance system ,train information display, data network equipments and other telecom assets at csmt station in mumbai division of central railway".
Tender For supply of isolated internet network-, network layer 2 access switch with 24 ethernet port and 4 sfp 10g uplink ports loaded with two single mode transceiver/ fibre modules as per specification attached in annexure-i), network layer 2 access switch with 24 ethernet port and 4 sfp 1g uplink ports detail specification attached in annexure-i), 12u rack enclosure (detail specification attached in annexure-i), cat6 utp cable roll (detail specification attached in annexure-i), cat6 utp patch panel (detail specification attached in annexure-i), cat6 utp patch cord (detail specification attached in annexure-i), cat 6 information outlet specification attached in annexure-i) (detail, single mode duplex fiber patch cord lc-lc type (detail specification attached in ?????uro d, installation of racks including mounting of switches, utp patch panel etc. with marking/ tagging of each port corresponding to i/o port and proper cable dressing. this also include switch configurations. (detail specification attached in annexure-ii), testing and documentation of utp nodes using pentascan/fluke or other equivalent network testing tools (detail specification attached in annexure-ii), , , ,