Get complete information related to latest Control Module Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Control Module Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Control Module Tenders.
Tender For corrigendum : tender for supply of procurement of spare of lt vfd at hurl sindri on oem basis : : - dual temperature transmitter, filter capacitor for sine wave fitter, "current transformer ratio 100/1avfd control devicevfd power devicehrc fuse link bs typefuse holders & isolating linkhrc fuse 8s typefuse-link rating-80a, ac 690 v.", fuse base nh din type, output filter ral 7035 size 6 inc, fan failure and temp detection unit, top (intelligent operator panel), "power contactor rating-45a, 230v acsine wave fitter reactor rating-22kw", panel fan, multi-function meter (mfm), 32-50 a, thermal overload relay, circuit breaker with electronic trip, panel door mounted rotary op, handles, d series dc drm relay, d series drm relay socket, 4 contacts, d series ac drm relay, sa, d series ac dirm relay, 10a, d series drm relay socket, 2 contacts, digital indicator (rpm meter), transformer, 415vac/240vac, 500va, auto transformer, 22kva 3 pole, current transducer specs 4-20ma, motor restart timer, green push button & contact block., red push button & contact block, selector switch, 2-way, selector switch, 3-way, blue push button & contact block, yellow push button & contact block, black push button & contact block, fuse terminal, thermostate, high current connectors, 40mm insulator, 30mm insulator, indicating lamp, red, indicating lamp, yellow, indicating lamp, blue, indicating lamp, green, indicating lamp, amber
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c
Tender For corrigendum : supply of supply of hydraulic power pack instruments spares under pac c c -electronic pressure transmitter with display model psd-4 0- 400 kg cm2 , hydraulic pressure switch 1ps 350 or 14 , valve high pressure hydraulic pressure relief dprh 06 k 400 , hydraulic solenoid valve with coil for main cylinder dke 1713 24vdc , coil for solenoid valve of main cylinder for dke 1713 24vdc valve , solenoid valve with coil for bomb door dhi 713 24vdc , coil for solenoid valve of bomb door for dhi 713 24vdc , hydraulic pressure gauge 0- 400bar 63mm dia 1 by 4 inch bottom connection , proximity switch for ps pnp 3 wire 24 v dc , timer panel , poppet solenoid valve , unloader valve pcm 20 -06-50-315 , unloader valve cartridge ppru-06-50 , block manifold for main cylinder , pilot optd. check valve ci10s 11 , bomb door pressure relief valve - rmp012ab , bomb door pilot check valve - hr012 , plate shifter pressure relief valve - rmo012b , bomb door counter balance valve cbs 10t11 , hydraulic fittings 16 mm ge-16-sr-half inch , hydraulic fittings 16 mm wno-16-s , hydraulic fittings 16 mm g-16- sr , hydraulic fittings 16 mm tee-16-sr , hydraulic fittings 16 mm seamless pipe-high pressure, in mtr , unit frl for instrument air 1 by 2 inch shavo , instrument air distribution header 8 way x 1 by 4 inch , push button with block 2no plus 2nc , mushroom emergency stop push- button with block 2no plus 2nc , mechanical high pressure relief valve, dprh 6k 315 , mechanical low pressure relief valve, unloader , solenoid valve with coil for bomb door , bomb door controlmodule. drawing as enclosed , solenoid valve with coil for main cylinder. drawing as enclosed , main cylinder control unit. drawing as enclosed , pressure regulator. drawing as enclosed , solenoid valve with coil for main cylinder ) /bid number : gem/2025/b/6900435 * /dated: 20-11-2025 & & / bid document 1 / 29
Tender For supply of supply and installation of microbial electroporation details as per bid : : - microbial electroporation system , electroporation pulse controller module , electroporation cuvettes , cuvette holder - cuvette rack , power cable
Tender For corrigendum : supply of oem spares for auma make electrical actuators - power module for graphical lcd module, controlmodule assembly, assembly of vb6-no. (k210.251)/3ph contactor with reversing links, selector switch (model: gst520 gt-cam switch), motor -mdev-071-00.060-4-415y5-f8-80-0000-kn/s(ax-01), base plate with 50 pin double seal connector sub assembly, retrofit kit + exp/50cc female connector + earthing cable sub assembly, mwg & isolation accessories (with programmed as per oa/model)
Tender For corrigendum : supply of replacement of lt incoming panels at various locations and cable termination d d - room panel-2 as per technical spec and sow. , supply of gas operator room panel-3 as per technical spec and sow. , install, replacement, testing and commissioning of gas operator room panel-3 as per technical spec and sow. , supply of 3. 5c x 400 sq. mm aluminum cable. ss4 to gas operator room as per technical spec and sow. , laying, fixing, testing and commissioning of 3. 5c x 400 sq. mm aluminum cable. ss4 to gas operator room as per technical spec and sow. , supply of 3. 5cx 70 sq. mm aluminum cable. ss4 to fire service dept. as per technical spec and sow. , laying, fixing, testing and commissioning of 3. 5cx 70 sq. mm aluminum cable. ss4 to fire service dept. as per technical spec and sow. , supply of 3. 5c x 25 sq. mm cable. pump house 1 to pump house operator room as per technical spec and sow. , laying, fixing, testing and commissioning of 3. 5c x 25 sq. mm cable. pump house 1 to pump house operator room as per technical spec and sow. , supply part for end termination. as per technical spec and sow. , service part for end termination. as per technical spec and sow. , supply part for new earthings with 75mm ci cast iron pipe and gi flat as per is standards 3043 and as per technical spec and sow , service part for new earthings with 75mm ci cast iron pipe and gi flat as per is standards 3043 and as per technical spec and sow , supply of gi flat 25 x 6mm necessary joints with nut and bolts from earth pit to panel boards. as per technical spec and sow. , laying of gi flat 25 x 6mm necessary joints with nut and bolts from earth pit to panel boards. as per technical spec and sow. , civil works - breaking of existing concrete and excavate the cable trench up to 60cm depth provide sand 45mm thick lay the3. 5 core 400sq. mm lt 1. 1kv ss4-gas operator room , civil works - breaking of existing black top road and excavate the cable trench up to 60 cm depth provide sand 45mm thick lay the 3. 5 core 70sq. mm lt. ss4 to fire service dept. , a. foundations for lt panels at all locations, b. creation of power room for lt panels in gas operator room with al partition
Tender For providing of operation and maintenance power house / power plant - complete system 630 kva 11/0.433 kv oil type transformer , 11kv vcb ht breaker pane, 1000amp main lt panel with bus coupler