Get complete information related to latest Control System Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Control System Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Control System Tenders.
Tender For providing of microcontroller based wireless controller system for water level management and other accessories etc. for the existing water supply system at transport authority, 5/9 under hill road, delhi.
Tender For design, manufacture, supply, delivery, installation and commissioning of odour controlsystem for 11 mld sewage treatment plant at puduthurai, karaikal
Tender For corrigendum : tender for supply of upper pole assembly complete with all internal parts including vaccum interrupter part no j71715199 , lower pole assembly complete with all internal parts including insulating studs and terminal part no j71715099 , vacuum interrupter part no 3vc200014 , spring charge motor part no 3vc400010 07 , closing coil assembly part no 4vc49110 , tripping coil assembly part no j4vc590189 , rectifier unit part no j9574194 , local remote switch 2 pole 2 part no j9574182 , breaker control swith 1 pole trip neutral close part no j9574183 , contact multiplication relay for 110dc antipumping part no j9574187 , winding temperature relay part no j479751 , master trip relay part no j479744 , heavy duty power pack 3 phase part no j479749 , facia enunciator 8 window part no j572656 , alarm bell hooter part no j309777 , power factor meter part no j479650 , self supervising numerical idmt relay highly sensitive for 3 o c and 1 e f broken conductor negative fase sequence protections suitable for cummunication and binary io configuration part no j573694 , bucholze alarm trip part no j480618 , oil temperature relay part no j479477 , trip neutral close switch part no j479677 , indicating lamp fitting set consist of 08 pcs part no j310092c , antipumpimg relay part no j479653 , ammeter selector switch part no j309025 , voltmeter selector switch part no j309024 , timer aux supply 220 v dc part no j9574215 , mechanism complete with spring charge motor 110v 220v dc part no j95736072
Tender For providing of customized amc/cmc for pre-owned products - replacement servicing of low side evaporator of huber make chiller at barc mysuru; huber process controls system; comprehensive maintenance contract (cmc); one time replacement with spare and servicing; ye..
Tender For tender for supply of 24vy8c010 3t crane for nopv - oil cooler , limit switch assembly slewing , limit switch assembly lowering/hoisting , control valve with levers , complete remote control unit
Tender For deequipping and destoring ofinfac t82 - 1 removal of fwd gun mount, qty-01. 1 no 2 removal of aft gun mount, qty-01. 1 no 3 blanking of fwd gun mount post, qty-01. 1 no 4 blanking of aft gun mount post, qty-01. 1 no 5 removal of small arms post- qty-02. 2 no 6 ra for removal of capstan. 1 no 7 blanking for weather proofing post removal of capstan. 1 no 8 removal of soft patches for both main engines, both gearbox, fwd da, ac plant. qty 02. 2 no 9 fitment of soft patches post removal of both main engines, both gearbox, fwd da, ac plant. qty 02. 2 no 10 removal/ degutting of both main engine and asd pump. 2 no 11 manufacturing of cradle (mat iron) and box (matwooden) for transportation of main engine.qty - 02. 2 no 12 manufacturing and fitment of dead weight and bilge plates. 1 no 13 removal of both main engine compensator bellow, qty 04. 4 no 14 removal of both main engine fuel water separator, qty 02. 2 no 15 removal/ degutting of both gearbox. 2 no 16 manufacturing of cradle (mat iron) and box (mat wooden) for transportation of both gearbox. qty - 02. 2 no 17 manufacturing and fitment of dead weight and bilge plates for both gear box. 18 manufacturing and fitment of dead weight for both asd - 14 2 no 19 manufacturing and fitment of dead weight for both propellers. 2 no 20 removal/ degutting of ac plant and its auxiliary. list of auxiliaries:- (a) tev (thermostat expansion valve. (b) heat exchanger (condenser). (c) heat exchanger (chiller). 1 job 21 manufacturing and fitment of dead weight for ac plant. 1 no 22 decouple and removal/ degutting of fwd da 1 no 23 manufacturing of cradle (mat iron) and box (mat wooden) for transportation of fwd da. 1 no 24 manufacturing and fitment of dead weight and bilge plates for fwd da. 1 no 25 decouple and removal/ degutting of aft da. 1 no 26 manufacturing of cradle (mat iron) and box (mat wooden) for transportation of aft da. 1 no 27 manufacturing and fitment of dead weight and bilge plates of aft da 1 no 28 removal of hp pump of ro plant. 1 no 29 removal/ de-gutting of ro plant. 1 no 30 manufacturing and fitment of dead weight and bilge plates for ro plant 1 no 31 removal of soft patches for aft da and ro plant. 1 job 32 fitment of soft patches for aft da and ro plant. 1 job 33 removal/ de-gutting of mcs 5 controlsystem with it s auxiliary. list of auxiliaries:- (a) lop 02 (b) junction box 02 (c) rcs 04 (d) ecs -02 (e) throttle lever 04 1 job 34 blanking of patches post removal of mcs 5 controlsystem to maintain weather proofing. 1 no 35 removal/ de-gutting of asd steering control box with accessories and it s auxiliary. list of auxiliaries are as follows:- (a) steering trim indicator 02 (b) main control 1 job page 3 / 13 panel 01 (c) asd controller 01 (d) trim controller lever 02 36 blanking of patches to maintain weather proofing for asd control box system. 1 no 37 removal of halon bottle 2 no 38 removal/ de-gutting of both shaft & support bearing 2 no 39 manufacturing of cradle (mat iron) and box (wooden) for transportation shaft & support bearing. qty 02. 2 no 40 requirement of tractor & trailer for shifting of items from ship to center for 20 days. 20 days 41 transport requirement (01 tonner) for shifting of items from ship to center for serviceability checks, 40 days. 40 days 42 requirement crane with sling (15,10,05,02 and 01 ton) for 40 days 40 days 43 removal of radar vm display, atu and antenna. 3 no 44 removal of existing cables of radar vm. 3 no 45 blanking and fitment of patches to maintain weather proofing 1 no 46 ra for degutting and de-equipping of ecdis display, ups, processor unit and interface unit with removal of cables. 4 no 47 removal of wind speed sensor and its dispaly unit and cables 1 no 48 blanking and fitment of patches to maintain weather proofing 1 no 49 removal of mss mk ii system, antenna and cables. 2 no 50 mk ii blanking of patches to maintain weather proofing. 1 no 51 removal of 07 in number navigation and emergency light. 7 no 52 manufactu