Tender For installation of motor pump and electricity connection to the existing borewell near rammandir at ward no 08 and providing drinking water facility for megalanayaka street under cmc limit chamarajanagar.
Tender For corrigendum : comprehensive operation and maintenance, routine repairs and special repairs of i.) rural piped water supply scheme (pws), ii.) single village piped water supply schemes (svs), iii.) ward level piped water supply schemes in non quality affected wards (wls _non quality) based on item rates; constructed by the public health engineering department including payment to the pump operators, electricity bills for five years under p.h. division, patna west, patna. (total no of schemes=17+24+159=200).
Tender For corrigendum : part i: fixed operation of ward level piped water supply schemes (quality affected/nq affected) & pws schemes by deploying pump operators and payment of electricity charges and part ii: variable comprehensive maintenance of ward level water supply schemes (quality affected/nq affected) & pws schemes, i/c the cost of chemicals, overhauling of filter media and related appurtenances, cleaning of esr and campus, maintenance viz. cleaning painting of pump house, boundary wall, repair of leakages in districbuition line, repair and provision of new fhtcs, repair amd maintenance of pumps and other electromechanical components etc. all complete as per the directions of engineer-in-charge. blocks: 09 blocks of munger district no. of schemes: 312 wls(non quality): - 174 wls(quality): - 127 pws/svs: - 11
Tender For corrigendum : comprehensive operation and maintenance, routine repairs and special repairs of (i.) rural piped water supply scheme (pws), (ii.) single village piped water supply schemes (svs), (iii.) ward level piped water supply schemes in quality affected wards (wls_quality) and (iv.) ward level piped water supply schemes in non quality affected wards (wls_non quality) based on item rates constructed by the public health engineering department including payment to the pump operators, electricity bills for five years under p.h. division, begusarai.
Tender For corrigendum : operation of pws/wls piped water supply schemes (quality affected/nq affected) by deploying pump operators and payment of electricity charges and ii. comprehensive maintenance of pws/wls water supply schemes (quality affected/nq affected) i/c the cost of chemicals, overhauling of filter media and related apputenances, cleaning of esr and campus, maintenance viz. claning painting of pump house, boundary wall, repair of leakages in districbuition line, repair and provision of new fhtcs, repair amd maintenance of pumps and other electromechanical components etc. all complete as per
Tender For supply of rubber sheet anti acid , oil and alkali resistant high power (2kv) electricity resistant , incompressible upto 6 ton load size: 1 mtr. x 2 mtr. x 25 mm thick confirming to is 5424 . [ warranty period: 24 months after the date of delivery ] ]
Tender For supply, termination installation, testing and commissioning of ventilation system in paint shop of lower parel workshop along with complete installation of industrial air blower with movable trolley, operating voltage 190v ac to 380 v ac, 50 hz, single/three phase supply, maximum power consumption shall be less than 600 watt, maximum speed of 400 rpm, air flow of 700 meter cube per minute, weight shallbe less than 60 kg and noise shall be less than 50db. size of blower shall not be more than 1500 mm diameter confirming to is 6272-1987 or latest all electrical works shall be carried out in accordance with the provision of indian electricity act 2003 and indian electricity rules 1956 amended to date and all the safety codes and procedures outlined in the safety codes shall be complied with general and safety requirement shall be governed by is 13947 (pt 1) 1993 and is:8623/1993, amended to date. termination of all cables shall be done with bimetallic terminal connector suitable for 2.5 dia aluminium tubular busbar for 20a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 2.5 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. materiat shall be confirmed to designation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 2.5. type test certificate from nabl or any other govt. agency lab report shall be attached along with the offer without which offer will be rejected. [ warranty period: 30 months after the date of delivery ] ]
Tender For collection of collection of collection of revenue/outstanding electricity b revenue/outstanding electricity b revenue/outstanding electricity bills from the active consumers active consumers onsumers of esd-i, dharmanagar under ed i, dharmanagar under ed i, dharmanagar under ed-dharmanagar dharmanagar dharmanagar of tsecl of tsecl of tsecl for 06(six)monthsthrough outsourcing through outsourcing through outsourcing.
Tender For providing of leasing in of commercial properties - office space; wet lease (maintenance to be borne by lessor); 5 years- 10 years; 1; ground floor; electricity back-up; yes; no; yes; 400