Tender For tender of labour charge for removal/transportation of silt, mud and water algae from cooling tower, cw pump house, clarifier & miscellaneous sump unit # 6 at utps. (civil ph)
Tender For supply of scavenge blower to tm/oil cooling unit including motor (wound with corona resistance wire) to specn. no.(i) clw/es/3/0021 alt-h & (ii) rdso specn no. spec/e- 10/3/09 with amendment 1 to 6 (motor). ]
Tender For cooling unit spares for chiller of bruke(2items) comprising of following: - indoor unit,f/tower ac,2tr(24000 btu/hr) , - outdoor unit,f/tower ac,2tr(24000btu/hr) ,
Tender For supply of self contained cooling unit for asw_swc by 523 , self contained cooling unit for asw_swc by 524 , self contained cooling unit for asw_swc by 525 , self contained cooling unit for asw_swc by 526 , self contained cooling unit for asw_swc by 527 , self contained cooling unit for asw_swc by 528 , self contained cooling unit for asw_swc by 529 , self contained cooling unit for asw_swc by 530 , installation assistance _supervison only_stw commissioning and trials for asw_swc by 523 , installation assistance _supervison only_stw commissioning and trials for asw_swc by 524 , installation assistance _supervison only_stw commissioning and trials for asw_swc by 525 , installation assistance _supervison only_stw commissioning and trials for asw_swc by 526 , installation assistance _supervison only_stw commissioning and trials for asw_swc by 527 , installation assistance _supervison only_stw commissioning and trials for asw_swc by 528 , installation assistance _supervison only_stw commissioning and trials for asw_swc by 529 , installation assistance _supervison only_stw commissioning and trials for asw_swc by 530
Tender For supply of split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2) (q2) , split air conditioner, floor mount type (v3) isi marked to is 1391 (part 2) (q2) , supply and fix window type air conditioner electric driven single phase cooling capacity 4500 k cal per hour 1.5 ton bee 3 star , material and labour for sub-main wiring surface type with two run of pvc insulated, unsheathed, frls single core and one run of 4.0 sqmm copper conductor , supply and fix single pole and neutral enclosure 240 volt, 20 amps with a two pin and earth plug and socket complete with one single pole mcb , supply and fix automatic voltage stablizer single phase 220 volt 50 hz of capacity 5 kva all as specified and as directed , m and l cutting chases, pinning in making good to facing where required and pointing in cement mortar 1-3 to ends or edges of landings, steps, cils, sunshades sheleves, lintels, etc , material and labour for sub-main wiring surface type with two run of pvc insulated.unsheathed, frls single core and one run of 6.0 sqmm copper conductor , m and l for stand bracket fabricated from structural steel section suitable for 3 ton ac outdoor unit including nut, bolt, washer, welding. bedding cold or hot , supply and fix single pole and neutral enclosure 240 volt, 40 amps with a two pin and earth plug and socket complete with one single pole mcb , supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and 90 v to 300 v with output voltage stabilized at 230 v , supply and fix voltage stabilizer for automatic operation single phase naturally air cooled indoor type and d 170-270 volt with output voltage stabilizer at 230 volt , s and f motor starter 25 amp with on off push type switch, modular type two module make make legrand-gm-havells , s and f socket 25 amp modular type two module make legrand-gm-havells , s and f metal flush box, modular type four module make legrand-gm-havells , s and f cover plate with metal frames, modular type four module make legrand-gm-avells , m and l for stand-bracket fabricated from structural steel section suitable for 1.5 ton- 2 ton ac outdoor unit including nut, bolt, washer, welding. bedding cold or hof, drilling holes for bolts , supply and fix power socket 240 volt ac 25 a 2 module all as specified and directed , supply and fix 25 a motor starter 2 module all as specified and directed , supply and fix modular white cover plate metallic frame 2 module all as specified and directed , supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 90 v to 300 v 230 v //bid details 2 / 25
Tender For ttps - mech.ii - tm ii renewal of worn out condenser cooling water inlet pipe line (east & west) and rubber expansion bellows during erection of new debris filter complete assembly system in unit iv note: prospective bidders may get the specification free of cost by down loading from tangedco :www.tangedco.gov.in nic:http://www.tntenders.gov.in/nicgep/app
Tender For corrigendum : tggenco-ytps(5x800mw)-supply of single compound to control scaling and corrosion (antiscalant) for cooling water treatment of unit-1 and unit-2 of ytps
Tender For corrigendum : dismantling, fabrication and erection of electrolyser reactor cooler cooling water inlet and outlet line in clo2 plant at pulp mill - mechanical in tnpl unit - i