Tender For auction sale of used lube oil,used lube oil with barrel 210 ltr,scrap water wall boiler tube (cs),scrap gear box assy.of cooling tower (ci & gear steel),scrap different size of valves (cs),scrap ms pipes different size,scrap insulation aluminium sheet,scrap paint drum ms & pvc 10/15 ltr,scrap paint drum ms & pvc 18/20 ltr
Tender For corrigendum : supply of for f1 selector sil , piston head disc for break cylinder , gasket kit for d1 emergency valve , gasket kit for va1b valve , gasket kit for mu2b selector , gasket kit for auto drain valve , gasket kit for c3w distributor valve of wdg3a locos , weather strip side , weather strip top horn , diaphragm horn dual tone , gasket 18 swg system water cooling , victaulic couling 3 inch flexible pipe coupling , gasket coupling , coupling 3inch dresser , gasket armoured 3inch , gasket rediator header , gasket armoured 1 by 2inch , gasket armoured , gasket armoured 1 by 4 inch , coupling 1inch dresser , dresser coupling , dresser coupling 3 by 4inch long compressor and exhaust unit , gasket lp cylinder head , gasket lp cylinder cylinder liner , gasket top cylider liner to block , gasket center or bottom cylinder liner to block cylinder head to block , gasket elbow to block , gasket elbow to head cylinder head , grommet push rod sleeve , gasket elbow to cylinder , gasket elbow to cylinder head piping lubricant oil , dresser 2 1 by 2 inch pipe strainer to base piping water , gasket branch pipe to header , gasket branch pipe to cylinder head , gasket pipe to pump , gasket pipe to cylinder block , gasket elbow to pipe and after cooler , gasket pipe to after cooler exhaust manifold , gasket manifold to cylinder head auxiliary generator and exciter , o ring between auxiliary generator to flange , gasket palm hose for brake hose pipes , after cooler gasket , gasket for lac support to lac assly , gasket inspection floors , large after cooler gasket , gasket to water pump and water inlet pipes , gasket for fttm blower , o ring 1inch od , rubber block for flexible coupling , o ring tube to cylinder head , gasket cover to base , gasket cover to lube oil filter drum , gasket kit for autodrain valve , gaket kit for c3 distributor valve , gasket armoured 1by4inch , gasket lp cylinder , weather strip top , gasket kit for vcd , gaket kit epg , gasket kit horn magnet valve , gasket kit for feed d24 b valve set , gasket center or bottom cylinder liner to block , rubber part kit for d24b feed valve , rubber part kit for n1 reducing valve , gasket kit for angle cork , mu washers , fuel oil filter gaskets , inchoinch ring for split flange , oil seal for water pump , oil seal for after cooler blower , strainer o ring , primary fuel filter gasket rubber
Tender For corrigendum : 7766/p-3/emp-13230 dt. 16.01.2026 for procurement of spares for window split package ac at ggsstp ropar - universal remote kit including thermostat and pcb for 1.5 tr window ac, universal remote kit including thermostat and pcb for 1.5 tr split ac, fan motor for condensing unit without fan blade (outdoor unit) model-lm200lk 4038, capacitor 10 mfd.,1ph, 450 w 1330 rpm make-godrej, ac coil cleaning liquid c-shine or equivalent, fan motor for lg make window ac 1.5 ton, 29kge775t, 220volt, 1.25 amp, 880 rpm, 50 hz, 1 phase, 149 volt, capacity 10.0/370 volt, cpn-h102-00311g, cu winding, fan motor for voltas make window ac 1.5 ton, 230 v, 50 hz,1 ph.,1/7hp, rpm 915/890/865,cap. 6.0/440v, model 29sahg058, marathon/ge or equivalent, cu winding, dryers size 5/8"* 5/8" flare 6" long danfoss/catch all/dry all, 3-phase ac contactors, coil voltage- 220 v current rating :- 32 amp, copper elbow size 1-1/8 , capillary tube 0.60 , heavy duty copper tube 1/4 , insulation sleeve 1/4 for ac, condenser fan motor, make ge india limited or equivalent, 1 phase, 1.5 a, 1/5 hp, 149 watts , 920 rpm, class- b insulation, cu winding., brazing rod, cu elbow size 3/8 , supply lead 3 core 2.5 mm2 with earth wire of make rr kabel/polycab/havells /finolex /kei, running capacitor 6mfd (keltron/epcos), dual run capacitor 50x4 mfd (keltron/ epcos), running capacitor 4mfd (keltron/epcos), starting capacitor 80/100mfd (keltron/epcos), thermally protected scroll compressor unit of capacity 7.5tr voltage-415v, 3 phase, 50 hz, make voltas /kirloskar/ copeland, cooling coil for 11tr package ac unit model 1108, as per attached sketch a , rotary compressor for 1.5 ton lg make window ac, 1 phase, 50hz, 220-240v,r-22 gas make: lg/highly/hitachi/ carrier, rotary compressor for 1.5 ton lg make split ac model 5cw2af5 make: lg/highly/hitachi/ carrier, sealed compressor 1.5tr, 3 phase,415v, kch 522 hae for hydrogen drier, compressor model kce 461 hae for 80/120 ltr. water coolers emerson copeland make, fan motor along with base without fan brg. type, self-lubricated. 1/34hp, 230v,1 phase, 50 hz, 940 rpm,ge/marathon make for water coolers., epcos make dual run capacitor 55+6 mfd +5%,440 vac,50/60hz for 1.5 tr window ac, outdoor fan motor for split ac 1.5 tr lg make, flair nut brass pin valve , epcos make dual run capacitor 50+10 mfd +5%,440 vac,50/60hz for 1.5 tr window ac, straight thimble for window ac size 4mm heavy duty copper (1pkt=100 nos.), angular thimble for window ac size 4mm heavy duty copper (1pkt=100 nos.), copper elbow size 1-1/2 , copper pipe 1-1/2 , running capacitor 10 mfd (tecumesh keltron/epcos), refrigerant gas drier 3"/8 l5 dn-50, over load protector for kce 461, lg condenser split ac 2.0 tr, capillary tube 0.50 , wall hanging thermometer measuring temperature 10-50 degrees with marking on glass stem., contactor with over load relay 7 to 16 a for 2.5 tr compressor, starting relay for compressor model sr 1012, rotary compressor for 2.0 ton lg make window ac, 1 phase, 50hz, 220-240v,r-22 gas, make: lg/highly/hitachi/carrier, box type relay for ac/water coolers for 1.0 to 2.0 ton., split ac indoor unit of voltas make of model 2.0t voltas 245 dy, r-22 having idu code 4551692., split ac copper condenser of 2tr compatible to model voltas 245 dy., split ac rotary compressor of 2tr of ac model 2.0t voltas 245 dy, r-22. compressor model no. ph340g2c-7mul, 230v, 50 hz, voltas 2tr split ac of model voltas 245 dy outdoor fan motor e-157 v-230, hz-50, a 0.75, rpm 850, phase-1, watt-93, hp-1/8 class-b insulation, cu winding., condenser for compressor model kce 443 hae for 60/80 ltr. water coolers, condenser for compressor model kce 461 hae for 80/120 ltr. water coolers
Tender For maintenance contract of turbine and auxiliaries in a thermal power plant of 2x500 mw dtps anpara b b - overhauling of tdbfp aop onejob consists of one pump , major inspection or overhauling of tdbfp eop onejob consists of one pump , cleaning inspection and rectification of tube leakages if any of lube oil coolers of mdbfp onejob consists of one cooler , cleaning inspection and rectification of tube leakages if any of working oil coolers of mdbfp one job consists of one cooler , inspection oroverhauling of cot or dot room transferoil pumps one job consists of one pump , overhauling of transfer oil pumps or gear oil pumpsand other similar pumps one job consists of one pump , replacement of coupling of transfer oil pumps or gear oil pumps or tdbfp jops and other similar pumps one job consists of one pump , axial and radial alignment of transfer oil pump or recirculation pump or tdbfp jop cot or dot room transfer oil l pump and other similar pumps one jobconsists of one pump , overhauling of vapour extractor of mot or control fluid tank or tdbfp oil tank and seal steam system one job consists one vapour extractor , cleaning of centrifuge bowl of tdbfp one job consists of one centrifuge bowl , overhauling of recirculation pump of vacuum pump , cleaning of tdbfp oil tank one job consists ofone oil tank , cleaning of main oil tank of turbine or cot or dot one job consists of one tank , alignment and adjustment of recirculation pump withmotor , cleaning of centrifuge bowl of main turbine and cot or dot one job consists of one centrifuge bowl , replacement of the burst atmospheric relief diaphragm of lp turbine , inspection or cleaning flushing and normalization of condenser hot well , inspection or cleaning flushing and normalization of deaerator , inspection or cleaning flushing and normalization of feed water storage tank , inspection or cleaning flushing and normalization of tg or sg ecw tank one job consists of one tank , replacement of turbine hp orlp bypass oil and minor revisioning of hp bypass oil system , centrifuging of lube oil through portable centrifuging machine , inspection or cleaning of sg plate heat exchanger , inspection or cleaning of tg plate heat exchanger , inspection cleaning and revisioning of acw pump suction strainer one job consists of 01 strainer , filling flushing and normalization of tg or sg ecw system one job per coolingsystem , cleaning and revisioning of tdbfp aop suctionfilter one job per filter , cleaning and revisioning of duplex lube oil filterof tdbfp one job per filter , cleaning and revisioning of eop filter of tdbfp , cleaning and revisioning of lube oil filter of mdbfp one job per filter , cleaning of duplex lube oil filter of main turbine one job per filter , cleaning of jop duplex filter of main turbine one job per filter , cleaning of bucket filter of main oil tank or control fluid tank one job per filter , cleaning of self cleaning filter of protection rack of main turbine 1 job consists of two filters , inspection or replacement of dry filter or mechanical filter super fine filter one job per set , inspection or replacement of fuller earth filter one job per set , cleaning of duplex filter mounted on valve rack of governing system of main turbine one job per filter , cleaning of cep suction strainer or bfp booster pump suction strainer one job per strainer , cleaning of bfp conical strainer one job per strainer , revisioning or replacement or cleaning of pilot valve of main turbine one job consists one pilot , revisioning or replacement or cleaning of pilot valve of m c v or aux c v of tdbfp one job consists one pilot , servicing of isolating valve control valve and nrvsof condensate line tdbfp extraction extraction 5 and booster pump suction line //bid details3 / 108size400 mm class150 to 300 , servicing of isolating valve control valve and nrvs installed on bfp discharge feed discharge line hph inlet or outlet hph 50 percentage bypass and other similar valve , servicing of hph 100 pe