Tender For survey design fabrication supply installation testing commissioning of on-grid solar rooftop project with net meter and remote monitoring system of 134 kw at various 10 govt/ semi govt offices buildings in satara dist. of maharashtra with cmc 5 years
Tender For supply of dc lead acid or ni cd batteries for ntpc lara project - 220v lead acid or ni cd battery suitable for main plant , electrolyte for first filling plus 10percent extra in nonreturnable container , wooden racks , stand insulators , intercell, inter row, inter bank connectors , cell numbering tags with fixing arrangement 1set , anti-splash type vent plug , nickle coated connection hardware plus 5percent extra , cable clamps with fixing hardware , pvc or cfrp spill trays under battery set battery to have spill tray covering every cell , battery trolley for entire project , hydrometer , cell testing digital voltmeter 3-0-3v with testing leads , wall mounting type holder for hydrometer and thermometer , set of hydrometer syringes suitable for vent holes in different cells , thermometer for measuring electrolyte temperature , specific gravity correction chart for lead acid battery only , rubber apron , pair of rubber hand gloves , set of spanners , no smoking notice , goggles industrial , instruction card , minimum and maximum temperature indicator for each battery room , acid or alkali mixing jar , battery health monitoring system for each battey cell of battery sets as per sl.no. a.1.1 above , 220v lead acid or ni cd battery suitable for offsite area , electrolyte for first filling plus 10percent extra , ms racks properly treated with alkali resistance powder , stand insulators plus 5percent extra , intercell inter row inter bank connectors , e and c spares for battery 1 and 2 gloves , e and c spares for battery 1 and 2 vent plugs , e and c spares for battery 1 and 2 intercell connectors , supervision of erection -battery -mandays , supervision of erection -battery -visit , supervision of commissioning -battery -mandays , supervision of commissioning -battery -visit , supervision of commissioning -bhms -mandays , supervision of commissioning -bhms -visit , mandatory spares for battery 1 complete dry cell , mandatory spares for battery 1 inter-cell connectors with hardware , mandatory spares for battery 1 bhms spares , mandatory spares for battery 2 complete dry cell , mandatory spares for battery 2 inter-cell connectors with hardware
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi
Tender For corrigendum : implementation of energy efficiency project for streetlighting system by replacement of existing street lights (including existing led street lights) with energy efficient led street lights and installing centralized control & monitoring system with an implementation period of 8 months extendable by additional 2 months with liquidated damages along with operation and maintainance for a period of 7 years after the project commercial operation.
Tender For corrigendum : request for proposal for selection and appointment of project management consultant (pmc) for supervision and monitoring of under ground sewerage scheme including collection system and sewerage treatment plant (stp) in kallakurichi municipality
Tender For restoration of irrigation system for effective water regulation including monitoring and management to regulator gates etc.. of right main canal, polavaram irrigation project (km 71.500 to km 133.800)
Tender For restoration of irrigation system for effective water regulation including monitoring and management to 18r of vizianagaram branch canal rmc of sgl thotapalli barrage project from km 0.00 to km 2.100 to improve its water carrying capacity.
Tender For restoration of irrigation system for effective water regulation including monitoring and management to main canal & distributary system of new rmc of sgl thotapalli barrage project package 2 (km 52.450 to km 117.890) to improve its water carrying capacity
Tender For restoration of irrigation system for effective water regulation including monitoring and management of pump house, transformer yard &pressure main of madhavaram lis under guru raghavendra project at rampuram(v),mantralayam (m), kurnool district