Get complete information related to latest Ct Pt Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ct Pt Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ct Pt Repair Tenders.
Tender For repair, maintenance, and installation of plant/ systems/equipments (version 2) - npcil office cum transit accom at noida; as per scope of work; as per scope of work- operation and maintenance of various systems, equipment and fittings and supply of items at npcil office cum transit accommodation at noida - 1.1 providing supervisory services for operation & maintenance activity of office cum transit accommodation for o&m work of 11 kv/415v/240v systems, domestic water / fire water/ r.o. water/, air conditioners, water coolers, d.g sets, lighting systems, earth pits, , telephone. lines distribution systems, maintenance of lawns, flowerpots, rectification of deficiencies related to civil work like plumbing, carpentry / masonry work and office work etc. cleaning of underground water tanks, and overhead water tanks. regular check of lighting system of the building and repair and replacement of bulb, choke, holder starter and office work etc. one activity shall be considered completed by deputing one highly skilled manpower as per qualification given in tech. spec. for 9 hours in a day as per work requirement. due to sensitivity of nature of work required round the clock 1.1 highly skilled supervisor will be available round the clock for any instance and requirement as the case may be. 1.2 providing services of technician in skilled category round the clock for o & m activity at noida office cum transit accommodation for following activities :- (i) operation & maintenance of 11 kv system/equipment & transformer:- cleaning and area up keeping of 11 kv switch gear panel and transformer and replacement of silica gel in 315 kva transformer if colour changes. ht drop out fuse and condition monitoring of complete switch gear area, 315 kva transformer oil level in conservator will be checked in one month. the oil level must be maintained between 25%-75%, if it reduces it should be topped up by new tested insulating oil of hv grade per is-335. bushing are to be examined for crack and dirt deposit and are to be cleaned or replaced as necessary once in six months or earlier if required. noise/humming sound, temperature rise (over heating) and crack in bituminous compound once in a month, general cleaning of the transformer to keep it free from dust and soot s quarterly or as required. (ii) preventive maintenance of two (02) nos. 415 volts air circuit breaker, 11 kv vcb (01 nos.) and switch gear area up keeping. the contractor is also responsible for maintaining 230 volts ac distribution systems in healthy condition. the scope of work includes maintenance of db s panels, & switchgear to ensure the functioning of fan, light, distribution of electricity within noida office cum transit accommodation building. the required spares shall be provided by npcil however consumables & hard wares e.g. lubricant, petroleum jelly, tb nut bolt, lugs etc shall be provided by contractor. (iii) operation & maintenance of domestic water/fire water system: the scope of work includes operation of bore well to maintain fire water tank level. preventive maintenance of domestic and fire water system, routine testing of fire water hydrants/pumps both diesel operated and electrical pumps. dewatering and cleaning of underground fire water tank and domestic water tank six monthly. (iv) cleaning of 2 no s of overhead fire tank of 5000 liter capacity and one no. domestic water overhead tank of capacity 5000 liter and one number of solar water tank six monthly, servicing and lubrication of 2 number of domestic water pump, 3 no. sump pump. servicing and lubrication of jockey pump, main hydrant pump, fire engine pump. the required all spares parts, hardware s e.g. lubricant, petroleum jelly nut bolt, gasket etc. shall be provided by contractor. (v) operation and maintenance of solar water heating system will require weekly cleaning of solar water panel, heater replacement and maintaining temperature with heater, repair and replacement of rubber
Tender For tender for supply of enm electrical spares item - spout bushing insulator w stud 800 1250a , magn contact or coil 110v 170amp3tf5402 , no volt coil under voltage coil , rose contact , brass cable gland complete set , auxilliary transformer 400va pri 500 52 , bshg outgng insultr 11kv 800 400a , contact fixed
Tender For supply of electrical and mechanical spares - 34700031 rocker switch on and off , 36g00035 potentiometer 470 k , e25 101042 1 pcb 3pin , 34700112 reset switch p and c , 34700034 feed switch red , 500405 belt m 28 c , 44100197 feed belt k 19 p and c , 5s300002 exit guide adjustable 6 15mm , 5s300133 spring set , 51300056 clutch disc , 53300004 heater blade indian and chali , 34700026 micro switch extra light , 34700025 micro switch heavy , cycle sensor model nobel059 , plunger assembly itw280 iii 0270 77 , 519112 end grip assembly 533612 , 1306 08 transformer heater 210 240v , meanwell power supply type sdr
Tender For comprehensive operation and maintenance of the project mainly water treatment plant, different class, type and diameter pipes, pump houses, sumps, rcc esr, h.g.l.r, sluice valves, flow meters, non-return valve, pump, motor, capacitor, l.t. panels, l.t. cables and transformer installed at headwork and sub headwork including all materials and work includes replacement of spares for all equipment and maintenance of all civil structures and all electro-mechanical installation etc. complete. including submission of periodic mis reports on software. supply of potable water in accordance, maintaining residual chlorine, and all consumables. all type operations, preventive maintenance, overhauls and repair/ break down maintenance for civil / mechanical & electrical works. providing prescribed nos. of qualified and experienced staff for overall management of o&m work as per detailed specification & obligatory requirement for 3 month (16 march 2025 to 15 june 2025). excluding electric power, raw water cost and excluding chlorine gas, pac and bleaching powder under gadkhol dadhal regional water supply schemes of tal.-ankleshwar dist.- bharuch as per tender
Tender For electrical equipment - electrical equipments, circuit breaker study panel: - 3 pole miniature circuit breaker 16,20,30a fixed on the hylam sheet- one lamp load connected with the mcb- one 230v indicator lamp will be provided on the main board- mimic diagram printed on the hylam sheet., electrical connector switch wiring study panel:- 5a,16a switches are mounted on the hylam sheet- wiring for the switches connected with the lamp- easy wiring teaching panel with connectors.- electrical switch mimic diagram on the front panel, watt hour meter study panel:- watt hour meter (230v 20a ac) mounted on the hylam sheet with proper fuse production.- mcb fitted on the front panel- lamp load mounted on the front panel- electrical diagram printed on the panel- all the connectors are terminated for easy wiring.230 v 20 amps ac analog watt hour meter, miniature circuit transformer study panel:- differed type of step-down transformer 5v,9v, and 12v,- one number of step-up transformer also fitted on the panel.- proper banana connector for primary and secondary side- ac lamp load for testing the transformer output., different types of ac inductor study panel:- different type of inductor mounted on the panel- all inductors are hf ac inductors.- the inductors parameters are printed on the panel., hand drill (or screw gun) to mount panel and osb - drill machine 4500 rpm | hammer drill kit | power tools & drill machines | 400w power rating drill machine | efficient pistol grip drill (10 mm chuck size), voltage:230 v , weight:1.3 kg, frequency: 50 hzpower: 400 w, miniature circuit transformer, 230 v 20 amps ac analog watt hour meter, basic toolbox - 6 piece screw driver set of 0 & 1pt phillips or any equivalent make 1.4, 2,2.4, 3 mm slotted, hf ac based inductors, nema 4x pvc electrical cabinet., analog ammeter (analog ammeter, direct type, 1 , 72x72mm) measuring current range 10 to 100a, vfd control panel (750 mm (l), 750 mm (d), 1600+150 mm (h).) drive mains supply: single phase, 230v ac 10%, 50hz input voltage: single phase, 230v ac 10% output voltage: three phases output frequency range: 0 to 60hz (default range) with resolution of 0.01hzthree phase induction motor type:squirrel cage rating: 0.5hp voltage rating: 415v ac speed: 1440 rpm 5% insulation: class b/f , nema34 planetary geared stepper motor 750kgcm, manual ranging digital multimeter 750v 20a with temperature probe, motor rewinding machine and accessories material:mild steelpower source: electricmaximum coil dia:300 mmcapacity:200 coil per 8 hourautomation grade:automaticfrequency:50-60 hzvoltage:220 vphase:single phase., control panel for wiring harness assembly (6 pin 1.5 mm control panel wiring harness assembly) mounted on a table, nema 23 stepper motor, clamp meter - measures ac/dc current, voltage, resistance, and continuity. range: 0-600a, true rms, cat iii/iv safety rating., grounding tester - measures grounding resistance (0-2000 ), 3 or 4-pole testing, portable, battery-operated., electrical equipments - consumable items, 5mm shear cutters, gumboot steel toe safety shoes pvc, industry standard - heavy duty industrial line tester 500 - 750 volt, ring terminal cable connector (conn ring circ 10-12awg), electrical cables-1.0 sq.mm, 2.5sq.mm,4.0 sq.mm, 6.0 sq.mm,10.0 sq.mm, cable wire (min number of equipment - 18 meter spool), jumper wire with clip (35mm double ended crocodile alligator clip with red and black wire electronic components electronic hobby kit), 3 pole miniature circuit breaker 16,20,30a set, 5a,16a electrical connector switch, stainless steel simple wire stripper with clampper, large wire / cable cutter (big head), (size: 10 inch), rubber hand gloves 12inchs, full body safety harnesses for protective construction, mnu industrial safety belt harness full body fall protection with scaffolding hook double lanyard unisex full body adjustable climbing harness safety belt, 12 pieces ring spanner set, industry standard measuring tape - 5m in case, standard (combinat
Tender For procurement of various electrical t and p items for 3x42mw larji hep - 3 phase relay test kit make omicron with standard wiring accessories includes following. cmc-500 with consisting of cmc 500 test unit - 1no. including manual, carry bag, power lead, ethernet patch cable, usb connection cable, 12 leads with 4 mm safety plugs, 12 flexible terminal adapters, 4 flexible jumpers for paralleling current triple a and b, basic test universe software package (tu 4.x), heavy-duty transport case with wheels for cmc 500, laptop- 1no, transformer winding resistance meter (micro ohm test kit) model trm25, make scope t&m pvt. ltd., 5 kv digital insulation resistance tester make- meggar model- mit 515 complete set, digital multimeter, make fluke, model- fluke 107, digital multimeter, true rms, make fluke, model- fluke 175, digital clamp meter 1000a ac/dc, make- fluke, model-319, milli amp process clamp meter, make- fluke, model- fluke-773, digital clamp meter 200 amp, ac/dc, make-fluke, model-362
Tender For construction and dismantling of 11kv line using cc, 100kva transformer insertions, construction of dp and installing ab switch and construction of plinth for transformer rearrangement, all at various locations under electrical section oachira.