Tender For rate contract for electrical material supply and repair for 01 year rate contract for electrical material supply and repair for 01 year - item for annual supply, cooler fiber (medium size), cooler metal (medium size), jumbo cooler, wall fan (400 mm sweep), pedestal fan, ceiling fan (1200 mm sweep), cable 3 core 2.5 sq. mm (90 mtr), 3 pin top 16 amp. (modular), switch 6 amp. (modular), socket 6 amp. (modular), china clip (packet), electric tape, exhaust fan 12" (metal), exhaust fan 9" (metal), exhaust fan 9" (plastic), wire 1.5 mm (isi) (90 mtr), pvc pipe 1.5 mm 1", pvc bend 1", pvc junction box 1", shaddle 25 mm, tube light led 20 watt, 6 module plate (modular), 8 module plate (modular), 6 module pvc box (modular), 8 module pvc box (modular), tpn 63 amp., mccb (200 amp), mcb sp (5-32 amp), 2x2 panel light (30 watt), switch 16 amp. (modular), socket 16 amp. (modular), telephone beetal n-88, telephone beetal c-51, wall fan motor rewinding, ceiling fan motor rewinding, exhaust fan motor rewinding, call bell wireless (electric), cat-6 cable, led bulb 9 watt, led light down lighter 5"x5" square, led light down 8"x8" square, led light down 12"x12" square, led light panel repair (dots & driver) 2x2 square, split ac service (1.5 ton), split ac gas recharge full (1.5 ton), split ac gas top up (1.5 ton), split ac nitrogen testing (1.5 ton), split ac condenser coil (copper) change with gas (1.5 ton), split ac compressor replacement (1.5 ton), split ac running capacitor, split ac 2 ton (inverter 5star) supply & installation, split ac 1.5 ton (inverter 5 star) supply & installation, ac copper pipe (3/8" and 5/8"), dg set servicing- 320 kva (only from mahindra s authorized dealer), transformer servicing- 315 kva, 33/11/0.433 kv substation maintenance (painting, do fuse, jumper, nut bolt, all necessory item), motor repair (5 hp), discharge rod, safety helmet, hand gloves (11 kv), safety shoes, foldable ladder aluminium (6 steps), cutting plyer, screw driver, tester, rinch set (5cm - 22cm), hammer drill machine, clamp meter, ups (600va), epabx card replace, epabx card repair, sofa & chair cleaning (per seat ), extension board (for computer)
Tender For repair of electric and electronic equipments-, in, rewinding of ceiling fan 48,", b, c, rewinding of ceiling fan 36", 2, rewinding of ceiling fan 60", b, rewinding of exhaust fan 15" 12, rewinding of exhaust fan 18", rewinding of exhaust fan 24", 3, rewinding of 1.0 hp booster motor pump with repairing, 4, rewinding of 1.5 hp booster motor pump with repairing, 5, replacement of ball bearing of celling fan 48", 56' 60", 6, replacement of ball bearing of exhaust fan 12", a, 15, b, 0, 18", 7a, 24", b, replacement of capacitor 2.5 mfd, replacement of capacitor 4.0 mfd/3.15 mfd, d, replacement of capacitor 5.0 mfd, 8, replacement of capacitor 10 mfd, 9a, replacement of gun metal bush for fan and motor pump, 5/f- of exhaust pan with frame 18-900rpm, /1400r pm 12"-900/1400 24"-900/1400rpm khatan/havells and equivalent, 10, 11, a , b , 12, 13, repairing of assorted size cooler cabinet with wood, wood pipe, bend tee 7 jalli and t&p , new submersible motor pump for cooler bansal , 8 no. 16watt , 12 no 35 watt , s/f new 06 ac vertical motor pump for cooler khatan / bansal and equivalent. , s/f new 10 ac horizontal motor pump for cooler khatan / bansal and equivalent. , 14, s/f new cooler tonkin of 20gauge in gi sheet , 15, s/f new cooler cabinet of 22gauge in gl sheet with all respective matarial , 16, cooler stand in angle iron frame , 17, s/f of asbestos sheet , 18a , b , 19, 20, 21, 22, 23, b , d-, s/f of rubber pipe 3/4" , s/f of rubber pipe 1" , service ro plant , service of baby warmer , repairing of monitor , puls oxymeter , spare part for repairing of ac 1.5 ton and 2 ton , running capacitor , starting capacitor , relay, , over load protector, , thermostat, , selector switch , capacitor, , condenser fan. , f-, fan motor , h , + , ? , k-, capillary, strainer, , condenser coil , cooling coil and gas charging. , 24(a) , repairing of fan motor for ac 1.5 ton , (b) , 25a , b , 26a , b , 2.0 ton , repl. of compressor for ac 1.5 ton , repl. of compressor for ac 2 ton , repl. of compressor for ac 1.5 ton , repl. of compressor for ac 2 ton , 27a , repressing of comp. system for ac, b , 28(al , 1.5 ton , repressing of comp. system for ac 2 ton , service overhauling ac 1.5 ten , b) , servicing & overhauling ac 2.0 ton , f , h , 29, spare part of refrigerators , -, b , d , starting capacitor, , running capacitor, , relay , overload protector switch. , thermostat, , selector switch , fan motor capacitor, , fan condenser , i , compressor, , stranger, , k , repossessing of system, , cooling condenser coil , 31, preparing of water cooler with spare parts , stanting capacitor , b , rumming capacitor , c , relay , d , overload protector switch , e , thermostat , f , h , selector switch , fan motor capacitor. , fan condenser, , compressor. , sttangor, , k , repossessing of system, , cooling condenser coil, , 32a , services charge of water cooler 25 ltr... , b , 50 ltr. , c , 150 lar , d , 200 ltr. , 33, repairing of auto voltage stabilizer 1.0 , kva , b , 2.0, kva , 3.0, kva , d , 40, kva , 5.0, xva , f , 6.00 kva , 34a , transformer 24x150kw , b , 12 x150 kw , 35, compressor (scroll type 8.3 tr , 36, compressor iscroll type) 5.5 tr, 37a , generator 125 kva , b , 250 kva , d , 400 kva , 38a , 625 kva , b , deep freeze-02 to 6 , c , deep freeze-20 , d , deep freeze -40 , 39, deep freeze -80 , lift (kone otis and other)
Tender For repair and maintenance infrastructure assets. sub head. replacement of cable, connection plate and motor fan at sarojini nagar water boosting station
Tender For various repair works on electrical systems - various defects on electrical equipment., l-1386 : 02 in nos cctv camera not working in pcr and amr. suspect both cameras defective. cameras to be repaired and proven for satisfactory operation. job involves laying of new lan cable approx length 90 mtrs from dchq to pcr and amr, connecting cameras with dvr., l-1387: ice cube maker not working view following defects: -(a) water inlet valve deteriorated and not allowing water to pass inside machine.(b) water pump defective.(c) compressor gas pressure showing low. gas to be refilled as required.ice cube machine to be removed from position and shifted to workshop for repair and refitment to be carried out post refitting. defect to be rectified and proven for satisfactory operation., l-1388: senior sailor water cooler not cooling water and not working. suspect compressor showing low freon gas. gas to be refilled to required pressure. defect to be rectified and proven for satisfactory operation., l-1389: mast base ventilation fan not working and showing low insulation. mast base ventilation fan (10 kw, 3 ph, 50hz) to be rewinded and proven for satisfactory operation., l-1390 : engineering workshop bench grinding machine not working view motor overheating and showing low insulation. bench grinding machine motor (5kw, 3 ph, 50 hz) to be rewinded and proven for satisfactory operation., l-1391: ahu 1 not working view control circuit malfunction. suspect olr and 02 relay malfunctioning. defect to be rectified and proven for satisfactory operation., l-1392: ibs acos (auto change over switch) not working. suspect contactor/relay malfunctioning. defect to be rectified and proven for satisfactory operation.
Tender For supply of 2t tower r32 general service , 1.5t split r32 general service , window 1.5t r32 general service , 1.5t split r22 general service , 2t split r22 general service , window 1.5t r22 general service , 1.5 split r410a general service , split removal , split installation with misc fastener , 2t tower pcb replace , 1.5t split pcb replace , 2t split pcb replace , window 1.5t pcb replace , 1.5t to 2t r32 supply and fill , 1.5t to 2t r22 supply and fill , 1.5t to 2t r410a supply and fill , 1.5t to 2t cu pipe condenser outlet , 1.5t to 2t cu pipe condenser inlet , 1.5t to 2t condenser fan motor replace , 1.5t to 2t drain pipe , 1.5t capacitor , 2t capacitor , 2t tower air filter replace , 1.5t split air filter replace , 2t split air filter replace , window 1.5 air filter replace , 1.5t to 2t blower fan motor replace , 1.5t to 2t swing motor replace , 1.5t to 2t insulation pipe with foam , 1.5t to 2t 16amp cable , 1.5t to 2t 16amp plug , 1.5t to 2t mcb 16amp , 1.5t to 2t mcb 32amp , 1.5t to 2t thermostat sensor , split mount bracket and fastner , window mounting bracket and fastner , 2t tower inside unit coil leakage repair , 1.5t split inside unit coil leakage repair , 2t split inside unit coil leakage repair , window 1.5t inside unit coil leakage repair , 2t tower outside unit coil leakage repair , 1.5t split outside unit coil leakage repair , 2t split outside unit coil leakage repair , window 1.5t outside unit coil leakage repair , 2t tower valve assembly replace , 1.5t split valve assembly replace , 2t split valve assembly replace , window 1.5 valve assembly replace , defective remote control replace , supply and install new stabilzer 1.5t , supply and intall new stabilizer 2t