Get complete information related to latest Dc Power Cable Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Dc Power Cable Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Dc Power Cable Tenders.
Tender For corrigendum : biennial rate contract tender for cable jointing or termination on hv or lv cables while attending underground cable faults at various locations in the area of electric supply distribution of the best undertaking, mumbai
Tender For corrigendum : repair and maintenance to lt electric supply and connected works at afs hakimpet under ge (af) hakimpet - note:-1. the contractor should visit the site before quoting the tender to know the working condition of the station.2. all requisite safely measures are to be adopted by contractor on site.3. the contractor shall provide and deploy sufficient electrician (as approved by ge / engineer in charge) shall report at 9:00 hrs to je e/m / engineer in charge to collect the complaints job card in working days and complete the same completed within 24 hrs.4. the complaints shall be rectified within 24 hrs if the complaints is/are not attended / not completed within 24 hrs (except repair/replacement of major items) recovery will be done at rs 500 per complaint per day.5. for major parts like replacement of mcb, dbs, mccbs etc should be rectified within 3 working days, if the contractor not rectify within time then recovery will be done at rs 1000 per complaint per day.6. after completion of job work complaint, the contractor has to produce job card duly signed by user & je / engineer in charge.7. if contractor failed to provide their electrician to attend the complains then recovery will be done at rs 1000 per day.8. the contractor should procure minimum 50% of the materials for all items as per boq (other than paints) mentioned in this ca, within 20 days after getting sample approval and kept in safe custody so that no delay in work due to non-availability of materials will be faced. contractor should ensure during the cause of work that he has minimum 25% of materials with him till the completion of work. if contractor fail to complete the work within contract due to lack of fittings a penalty of 20% shall be applicable on quoted rates by the contractor.9. in repair works, rate quoted for demolition /dismantling /taking down is deemed to be inclusive of removing the same from site and station.10. in maintenance works, the contractor should maintain separate registers for repair works. day to day complaints should be noted in those registers with si nos of complaints, location qty of work, status of complaints and signature of in charge and stamp of the office. formal will be given from concern age office. the contractor should obtain the signature of in charge on the same day of work. these register to be submitted to je (e/m) on every weekend without fail.11. the contracts involving working at elevated locations of buildings, contractor should ensure proper safety arrangements as per norms. wearing safety belts and helmets are mandatory. a penalty of rs 1000 per day will be recovered from contractor if safety norms are not followed.12. after completion of work, no stores/debris/ loose items be kept at work site or dumped inside station . entire area to be cleared and waste material be taken outside from the station ., excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting in hard/dense soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed by engineer-in-charge., boaring/ drilling (horizontally ) of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including hdpe pipe of 80 mm dia suitable for 0.4 mpa working pressure. all as specified and directed by engineer in charge.., supply and spread clean dry river sand in trenches for cushioning of cable complete all as specified and directed by engineer-in-charge. (note: punned down thickness only shall be measured for the purpose of payment), supply and fix precast concrete cable covers class lv type 1, flat size 250 x 150 x 40 mm m-20 grade concrete laid dry for cable protection complete all as specified and directed., returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by engineer-in-charge., removing surpl
Tender For supply and commissioning of ac high voltage test set (hv test kit 0-10 kv) input: 230 volts, 50 hz, single phase a c output : continuously variable from zero to 10 kv ac capacity : max. permissible tripping current is 100ma (tripping at 25ma, 50ma & 100ma selectable with auto hv off timer). heavy duty along with 6 meter long hv cable 3 meter long lv cable for input as per specification enclosed. note: 1)calibration certificate traceable to nabl accredited lab and test certificate to be provided by fir m along with supply. 2)firm other than oem to submit tender specific authorization letter from oem/ authorized dealer along with t heir offer otherwise offer will be passed over. 3)tenderer has to quote the make and model no. of offered product matching to ten der specification failing which their offer will be passed over. [ warranty period: 24 months after the date of delivery ]
Tender For supply of high frequency digital axle counter multi section type complete system includ ing central evaluator (s), final track clearance relay for each track section, reset boxes, lv boxes, dete ction points, mushroom housing for track side electronic and all other accessories fully wired to the ulti mate capacity and fully equipped to the configuration specified as per rdso specification no. rdso /s pn / 176/2013 (ver. 3) and oem specification for 24 detection points and 14 track sections. length of i nbuilt cable with axle detector shall be 15 meters ]
Tender For power transformer 33 kv, 500 kva, isi marked, as per conforming is:1180(part-i): 2014 with lates t, energy efficiency level 3 & bee star rating - 3, including installation testing civil work, input voltage - 33 kv & output voltage - 415 v, no load voltage ratios - 33/.433 kv, core material - crgo as per is:3024 latest, winding material of transformer copper & foundation mounted type, vector group dyn-11 with solidly earthing system ar rangement, noise level - 48 db, tank cover bolted type with radiator fins, cooling onan type, transformer body material used mild steel & bottom sheet thickness - 6 mm & side sheet of tank thickness - 4 mm, insulating oil to be used as per is:335 with supply of oil qty - 500 liter, on load tap charging arrangement with off circuit extern ally operated switch with mechanical interlocking device & position indicator, tapped positions 7 no with off posi tion, temprature indicator & non return valve with drain cum sampling valve, with provison of cable end box on lv side, warranty of transformer 48 months of commissioning material of rating plate - anodized aluminium with engraved marking of central govt. lab report for type test internal test report & routine test report short ckt with stand report with bis licence certificate & star rating certificate. make - kirloskar, crompton greaves, abb tesla or equivalent. [ warranty period: 48 months after the date of delivery ]
Tender For work of removal, laying and testing of h.v. / l.v. cables from / in cable trench/tray on as & when required basis of emdi/emd-ii/emd-v & emd-vii at wtps.