Web Analytics Made Easy - StatCounter

Decorative Light Repair Tenders

Get complete information related to latest Decorative Light Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Decorative Light Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Decorative Light Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :43742652 Due date: 09 Mar, 202609 Mar, 2026 NA
Tender For bid to ras supply of provn of 01 x relocatable cool room for patients fabricated using 01 x container d d -structural components should be made of mild steel framwork of ms square tubing and powder coated and dimension is 4500mm x 2270mm x 2000mm of is 2062 , puf sandwich wall panel 40 mm thick insulated total coverages is 2046 , frp internal lining smooth washable finish total coverages , partition panel with frp 40 mm puf with frp lining variable , marine plywood flooring 12 mm with antislip vinyl 4500mm x 2270mm is 710 , insulated door aluminium composite with rubber seals 900mm x 1800mm is 16049 , foldable stair ms power coted 1 point 48m lenght 1480mm x 600mm , office compartment of size 1 point 12m x 1 point 59m x 1 point 96m , office table laminted top of size is 1000mm x 600mm x 720mm is 11638 , executive chair swivel ergonomic of size is 600mm x 660mm x 850mm is 3743 , file cabinet mild steel of size is 600mm x 400mm x 800mm is 555 , medicine compartment of size is 1 point 12m x point 59m x 1 point 96m , deep freezer rating star 5 and capacity is 150 ltr convertible and puf insulated dimension is 1145mm x 735mm x 845mm is registration , mini refrigerator rating star 1 and capacity is 99 ltr direct cool isi marked dimension is 486mm x 567mm x 849mm is registration , medicine rack of ss modular with glass door and powder coated and dimension is 1800mm x 600mm x 300mm is 6911 , patient compartment of size is 2 point 02m x 1 point 59m x 1 point 96m , foldable patient beds made of custom fabricated ms frame and laminated plywood and dimension is 1900mm x 800mm x 600mm is 2973 , iv stands made of stainless steel and adjustable height and adjustable to 2000mm and is 12349 , patient or medical attendant chair made of stainless steels frame with padded seat of 450mm seat height , compact foldable table made of laminated top and metal frame dimension 800mm x 500mm x 720mm , bp monitor and stethoscope digital with standard dimension , first aid emergency kit isi standard a kit , colour coded biomedical waste segregation bins should be 15 ltrs ppcp polypropylene co polymer puncture proof and leak proof and tamper proof 1 x red 1 x yellow 1 x blue and dimension 280mm x 380mm , split ac rating 3 star and cap 1 ton energy efficient dimension is 1000mm x 300mm x 200mm , square led surface panel light should be 18w 230v ac 50hz with dimension 225mm x 225mm x 20 cutout size 200mm x 200mm is 16102 , emergency light with battery backup standard size , electrical wiring and mcb 16a with mcb protection complete system is 694 , ac installation complete installation with copper piping , electrical socket and charging points should be 5a or 15a modular sockets is 1293 , connection to deep freezer and refrigerator should be dedicated power lines with protection , ventilation system should be exhaust fan and air vents , rubber seal and gaskets for doors and windows , paint and finishing with exterior digital camo and interiror finish complete , fabrications and assembly labour for skilled labour charges , contigency testing commissioning

CTN :44362709 Due date: 17 Mar, 202617 Mar, 2026 NA
Tender For supply of split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2),split air conditioner, wall mount type (v3) isi marked to is 1391 (part 2),household refrigerating appliances as per is 17550,voltage stabilizer for automatic operation s p naturally air cooled indoor wall mounted type input varation bet 150 v tp 285 v capacity 5 kva as directed,water cooler fully stainless steel, electric driven single phase approx storage and nominal cooling capacity 40 80 ltrs as directed,modular plug and socket 25 amp, 3 pole having 6 modules having motor starter modular type 25 a mcb mini 3 ka socket 25 a suitable for ac supply as directed,install of hi wall split units indoor-outdoor complete with cordless remote control unit minimum 5 star ratio and ber 3 point 2 of capacity 1 point 5 tr as directed,install of hi wall split units indoor outdoor complete with cordless remote control unit minimum 5 star ratio and ber 3 point 2 of capacity 2 tr as directed,m and l point wiring complete with 4 sq mm frls multi stand

CTN :44340045 Due date: 17 Mar, 202617 Mar, 2026 NA
Tender For tender for supply of ht cable -m and l for searching fault location of ht ug cable 11000 volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse echo fault locator with frequency distance calculator etc incl transportation of machinery excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of engineer in charge note a charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate b necessary testing of cable after making joint will be deemed to be including in the cost of relevent item , supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 minus 185 sqmm xlpe cable of 11000 volts e grade complete all as specified and directed note cost of cutting of existing end termination joint deemed to be included in unit rate , m and l for cable jointing kit for 11 kv earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core xlpe armored aluminum conductor cable complete all as specified and directed , supplying and laying in repair xlpe insulated screened pvc bedded galvanized steel strip or wire armoured , electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 sqmm x 3 core complete all as specified and directed , supply and fixing in repair mccb 400 amps 3 pole 415 volt 36 ka including under voltage over voltage relay with adjutable thermal setting 80% minuse 100% all as specified and directed , m and l for complete repairing serviceing of ht 11 kv vaccum circuit breaker vcb after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with ht insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal ac dc circuit wiring repair servicing of breaker trolly including motorized operating mechanism ct pt power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow over current earth fault differential in sequence from down streem to receiving sub stn for accuracy and effective functioning of vcb complete all as specified and as directed note nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective ht 11 kv 2 amp fuse carrier oiling greasing to charging spring replacement of hrc fuse 110 220 volt 5 amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items , supply and fixing heater 230 volts ac 60 watt for 11 kv ht vcb panel complete all as specifed and as directed make heatco vileco electrical , supply and fixing in replecement of spring charging gear for 11kv vcb panel suitable for 630 400 amp complete all as specified and directed , supply and fixing vacuum interputer for ht11 kv vcbs 630 400 amps brakding capacity 13point 1 ka suitable for alstom make vcb complete all as specified and as directed , taking down and repairing overhauling of air break gang operated switch with do fuse unit 200 amp 400 amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the sam

Central Government And Public Sector

CTN :44344368 Due date: 17 Mar, 202617 Mar, 2026 3.14 Lacs
Tender For tender for supply of sitc of 1.5 tr split ac uits , copper pipe 6.4 mm dia with tube thickness 0.8 mm with insulation , copper pipe 12.7 mm dia with tube thickness 0.8 mm with insulation , 25 mm c-pvc pipe , ms stand of suiatble size for outdoor unit , supply & fixing of control cum transmission wiring and ac power supply cable 3x2.5 sqmm , supply & fixing of control cum transmission wiring and ac power supply cable 4x1.5 sqmm , supplying and fixing dp sheet steel enclosure complete

CTN :44344102 Due date: 13 Mar, 202613 Mar, 2026 NA
Tender For e-enquiry invitation of sealed quotations for work of supply and installation of ac supply wiring, data cable wiring and intercomm wiring alongwith all accessories for the 6 nos. of new cabins at msldc, airoli.

CTN :44327657 Due date: 20 Mar, 202620 Mar, 2026 NA
Tender For supply of file , supply of distribution board db made out of sheet metal enclosure crca sheet spn 12 way with 200 amps. complete all details specified in boq and addl work file , fixing of distribution board db made out of sheet metal enclosure crca sheet spn 12 way with 200 amps. complete all details specified in boq and addl work file , supply of single pole and neutral enclouser with a two pin and earth plug and socket. complete all details specified in boq and addl work file , fixing of single pole and neutral enclouser with a two pin and earth plug and socket. complete all details specified in boq and addl work file , supply of earthing complete with galvanised steel earth plate electrode 60x60cmx 6mm thick. complete all details specified in boq and addl work file , fixing of earthing complete with galvanised steel earth plate electrode 60x60cmx 6mm thick. complete all details specified in boq and addl work file , concealed point wiring complete using 1. 5 sqmm pvc copper conducto cable frlsh 1100 v, for one light fan point controlled by one swtch 5 amps. , fixing of concealed point wiring complete using 1. 5 sqmm pvc copper conducto cable frlsh 1100 v, for one light fan point controlled by one swtch 5 amps. , concealed point wiring complete using 1. 5 sqmm pvc copper conducto cable frlsh 1100 v, for one light fan point controlled 3 pin ,5 amps socket outlet in the same board. , fixing for concealed point wiring complete using 1. 5 sqmm pvc copper conducto cable frlsh 1100 v, for one light fan point controlled 3 pin ,5 amps socket outlet in the same board. , concealed point wiring complete using 1. 5 sqmm pvc copper conducto cable frlsh 1100 v, for one light fan point controlled 3 pin, 5 amps socket outlet in the independent board. , fixing of concealed point wiring complete using 1. 5 sqmm pvc copper conducto cable frlsh 1100 v, for one light fan point controlled 3 pin, 5 amps socket outlet in the independent board. , concealed point wiring complete using 1. 5 sqmm pvc copper conducto cable frlsh 1100 v, for one light fan point controlled by one bell push. , fixing concealed point wiring complete using 1. 5 sqmm pvc copper conducto cable frlsh 1100 v, for one light fan point controlled by one bell push. , concealed point wiring complete using 2. 5 sqmm pvc copper conducto cable frlsh 1100 v, for power point on independent board. , fixing of concealed point wiring complete using 2. 5 sqmm pvc copper conducto cable frlsh 1100 v, for power point on independent board. , concealed point wiring complete using 4. 0 sqmm pvc copper conducto cable frlsh 1100 v, for for ac socket on independent board. , fixing of concealed point wiring complete using 4. 0 sqmm pvc copper conducto cable frlsh 1100 v, for for ac socket on independent board. , supply of switch socket combination 5 pin, 5 amps flush type. complete all details specified in boq and addl work file , fixing of switch socket combination 5 pin, 5 amps flush type. complete all details specified in boq and addl work file , supply of switch socket combination 2 in 1, 5 by 16 amps flush type. complete all details specified in boq and addl work file , fixing switch socket combination 2 in 1, 5 by 16 amps flush type. complete all details specified in boq and addl work file , led street light fting 35 watt 230 v ac outdoor type. complete all details specified in boq and addl work file , fixing of led street light fting 35 watt 230 v ac outdoor type. complete all details specified in boq and addl work file , supply of switch piano flush, single pole, one way 5 amp complete all details specified in boq and //bid details2 / 54addl work file , fixing of switch piano flush, single pole, one way 5 amp complete all details specified in boq and addl work file , supply of bell electric ding dong 230 v complete all details specified in boq and addl work file , fixing for bell electric ding dong 230 v complete all details specified in boq and addl work file , supply of bell push 5 amps one w

Central Government/Public Sector

CTN :44334428 Due date: 16 Mar, 202616 Mar, 2026 3.53 Lacs
Tender For providing ac point wiring inside room no 604 at civil annex building yoga hall of new sports complex faulty rooms of shssm dept room no 601 of it dept and room no 304 of e and e department in nitk

State Government

CTN :44329228 Due date: 06 Mar, 202606 Mar, 2026 3.00 Lacs
Tender For ???? ?????????? ?????? ?? ??????? ???????? ??? ??????? ??? ??? ?????? ?? ??????? ???? ?? ?????? - rate contract for ac repair materials in various sections and wards of district hospital dholpur - heating condenser coil size 21x33 inches, with installation , gas charging, , gas charging, , gas charging, , motor ccf outdoor with installation, , blower fan motor with installation, , blower fan motor with installation, , workshop service split ac by opening external and internal units., running capacitor, , flare nut, , flare nut, , flare nut, , flare nut, , on spot vat service, , split ac pcb repair non inverter, , out door stainer filter, , out door fan blade, , copper pipe 1.5 ton, , copper pipe 2 ton, , electric wire, , compressor, , compressor, , new pcv indoor non inverter, , new pcv indoor non inverter, , new pcv indoor non inverter, , new pcv indoor model inverters, , new pcv indoor model inverters, , new pcv indoor model inverters, new pcv outdoor, , new pcv outdoor, , new pcv outdoor, , new blower, , indoor sensor inverter model, , indoor sensor non inverter model, , outdoor sensor non inverter model, , outdoor sensor inverter model, , indoor swing motor dc volt, , outdoor fan motor dc volt, , compressor wiring kit

CTN :44343227 Due date: 06 Mar, 202606 Mar, 2026 16.96 Lacs
Tender For provision of ac wiring to e.i in the court office & administrative office in the judgeship bhagalpur

Central Government/Public Sector

CTN :44332115 Due date: 31 Mar, 202631 Mar, 2026 NA
Tender For "provision of 4.5kw under-slung type regulated cum emergency battery charger along with wiring scheme in lhb eog ac coaches."
 Loading, Please wait...

Connect us via What's Up