Get complete information related to latest Disposable Syringes Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Disposable Syringes Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Disposable Syringes Tenders.
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposablesyringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr
Tender For supply of adult diaper extra large disposable contoured shape for better fitment inner absorbant pad to convert liquid into gel two pairs of refasten tape tabs , bandage elastic adhesive 6 cm x 4 metres unstretched and 5 to 6 metres when stretched. tin pack of one roll elastoplasterobqleukoband , non sterile surgical gloves size 7 1obq2 , pad abdominal swab 30 x30 cm with tape , absorbant cotton wool i. p 500gm non sterile , catheter suction endobronchial with terminal transparent nontotoxic pvc tubing size fg 16 length 50 cm , disposable drape sheet for ot size 100 cm x 120 cm , enteral feeding bag , powder free gloves latex gamma irridation size 7 , polyamide monofilament size 3obq0 70to100cm 3obq8 circle reverse cutting 25to30mm box of 12 foils , polyamide monofilament size 4obq0 80to100cm 3obq8 circle cutting 15to20mm box of 12 , polypropylene blue monofilament 70to75 cm size 3to0 1obq2 circle taper cut 25 mm double needle , polypropylene blue monofilament 70to75 cm size 3to0 3obq8 circle rb 13to25 mm , polypropylene blue monofilament 70to75 cm size 4to0 1obq2 circle rb 25 mm double needle , silk braided size 1obq0 70to76 cms taper cut 1obq2 circle needle 25mm , kirschner wire 250 mm long x 1. 0 mm dia both ends trocar point , kirschner wire 250 mm long x 1. 5 mm dia both ends trocar point , skin marking pen thick marking with a flexible scale sterile peel open pouch , kirschner wire 250 mm long x 2point0 mm dia both ends trocar point , kirschner wire smooth length 150 mm with double trocar tip 1point5 mm to 3 mm at 0point5 mm increments. , kirschner wire smooth length 150 mm with double end diamond tip 1point5 mm to 3 mm at 0point5 mm increments. , vascular tapes red , vascular tapes blue , pressure garment vest without arm large size , finger exerciser , pressure garment vest without arm ) /bid number: gem/2026/b/7109931 * /dated: 02-02-2026 & & / bid document1 / 41medium size , pressure garment vest without arm small size , baseball finger splint , foot drop splint , fibrin glue 2ml containing to fibrinogen 70to 110mg plasmafibronectin 2to9mg factor xiii 10to50u plasminogen 40to120mcg aprotinin solution , drill bit 2. 0 mm , drill bit 2. 7 mm , breast implants texturedobqsmoothobqovalobqanatomical shape size 190 , breast implants texturedobqsmoothobqovalobqanatomical shape size 230 , breast implants texturedobqsmoothobqovalobqanatomical shape size 270 , breast implants texturedobqsmoothobqovalobqanatomical shape size 500 , 26g 1obq2 inch disposable needle , monofilament polyglecaprone size 4to0 25mm round body needle 70to90cm e g monocryl box of 12 , monofilament polyglecaprone size 4to0 25mm cutting needle 70to90cm epointg monocryl box of 12 , cream lidocaine 205 percent plus prilocaine 2. 5 percent , sun block to oc 45 avovenzone oxyvenzone octyl methoxycinnamate homosalate octocrylene tocopheryl aceatete tea tree oil and titanium dioxide gel , dermal filler gel e. g juvederm , ktowire size 0. 8 mm both ends sharp , ktowire size 1. 0 mm both ends sharp , ktowire size 1. 5 mm both ends sharp , vascular tapes whiteobq yellow , silicon gel sheet 11to12 x 6to7 cm , silicon gel sheet 14to15 x 12to13 cm , silicon gel sheet 5 x 7point5 cm , padgett dermatome blade ref 3539to252 , padgett dermatome blade ref 3539to602 , steri strips packet of 3obq4 , steristrips box of 50 , reusable clip applicator for open surgery compatible with ligaclipto100 , reusable clip applicator for open surgery compatible with ligaclipto200 , reusable clip applicator for open surgery compatible with ligaclipto300