Get complete information related to latest Disposable Syringes Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Disposable Syringes Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Disposable Syringes Tenders.
Tender For bid to ras corrigendum : tender for supply of forceps dissecting15 cm , forceps dissecting toothed 18 cm , scissor , scissor surgical curved blunt pointed 11 point 5 cm , scissor surgical straight sharp pointed 11 point 5 cm , fork tuning gardiner brown 1024 vibrations per second , fork tuning gardiner brown 512 vibrations per second , speculum nasal size 3 cm , speculum nasal 5 cm , forceps uterine vulsellum teales with lateral curve 3 multiply 4 teeth screw joint 25 cm ss , sound uterine graduated from 4 to 20 cm 28 cm long ss , speculum vaginal duck bil double ended blade size 3 point 5 cm multiply 10 point 5 cm and 2 point 8 cm multiply 10 point 5 cm ss , bowl stainless steel 10 cm , bowl stainless steel 25 cm , tray ss shallow size 35 cm multiply 30 cm with cover , tray ss shallow size 27 point 50 cm multiply 22 point 50 cm with cover , scales baby weighing spring type with strong wicker basket to weigh up to10 kg complete , catheter female metal 8 english gauge ss , tube rectal flatus size 18 english catheter gauge , tube rectal flatus rubber size 7 english catheter gauge 76 point 20 cm long , tube stomach i point r point size19 length1 meter , slide microscope thickness 1 point 15 mm to1 point 35 mm size 76 mm multiply 50 mm , slide microscope thickness 1point15 to 1point 35 mm size 75 mm multiply 25 mm , urinometer , test type reading hindi and english double page in book form in plastic cove , test type distant vision set of 4 charts , torch hand chromium plated brass standard cells fitted with a bulb of 6 point 2 v without cell , curette sharp no 2 width of working part 9 mm carbon steel chromium plated , curette blunt no 2 width of working part 9 mm carbon steel chromium plated , dilators uterine hollow set of 16 conical metal size 3 by 6 to 18 by 21 mm dia in metal case
Tender For corrigendum : supply of schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.) - schedule iv (x-ray films, chemicals, e. c. g. rolls, materiels etc.), polyster base round corner x-ray films (8" x 10") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (10" x 12") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, polyster base round corner x-ray films (12" x 15") green sensitive, blue base with base fog less than or equal to 0.23 & dmax not less than 3.10 interleaved. the density values should be met at developer temperature 32 c to 35 c, dental x-ray films intraoral periapcal the density values should blue base with base fog less than or equal to 0.20 & dmax not less than 3.10 the density values should be met at developer temperature 32 c to 35 c, liquid developer replenisher for automatic processor (starter solution, if recommended by the manufacturer, should also be supplied), ( price of item no. 5 and item no. 6 will be considered as a unit), liquid fixer hardner for automatic processor ( price of item no. 5 and item no. 6 will be considered as a unit), inj. meglumine diatrizoate sodium diatrizoate iodine content 365-375 mg/ml in 20 ml. ampoule/vial, pigtail angiography catheter with multiple side holes length 65 to 75 cm 5f, inj. gadolinium based contrast for mri for liver/liver specific (should provide details of compound being hepatobiliary specific), inj. gadolinium based contrast for mri for general use, inj. gadolinium based contrast for mri for angiography, disp lure lock syringes 3 ml. for glue injection, disp lure lock syringes 1 ml. for glue injection, x-ray folders laminated 250 gsm 14 1/2" x 17 ", dual pack 200 ml syringe with aspirator, "y" shaped coiled tube y-tube sterile, non-pyrogenic (minimum 300 psi & above) compatible with dual head pressure injector ( lf/medrad/ sea crown / spectra / apollo), extension "y" shaped coiled tubing for injector 150 cms. (-5 or +15cm) low pressure (minimum 300 psi & above), dual disposablesyringes (60 to 65 ml each) with "y" or "t"shaped coiled tube connecting tubes small spike for contrast and large spike for saline compatible with mri injector (lf or medrad)., one way stopcock (high pressure), low pressure extension "y" or "t" shaped coiled tubing min. 150cms (-5 or +15 cms) with coiled connecting tubes & small spike for contrast & large spike for saline for medical mri injector., flavoured, ionic, water soluble, oral contrast iodine content 240-250 mg/ ml. in 30 ml, bernstein catheter 4 f 100 cm, bernstein catheter 5 f 100 cm, chiba needle 21 g 15 cms length, chiba needle 22 g 15 cms length, disposable c t scan pressure injector syringes (190 ml syringe + quick fill tube) for bayer medrad salient injector (toshiba / canon), extension "y" shaped coild tube adapter dual check valves (minimum psi 300 & above), nonionic iodixanol isoosmolar, 320 mg 50 ml, disposable mri syringes kit for 65/115 mr injector system 65 ml contrast syringes and 115 ml ns syringes with connecting tubing combo pack for spectris solaris medrad pressure injector, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 14 g & 10 cm in length, spring loaded fully automatic and semi automatic biopsy instrument with adjustable penetration depth of 18 mm and 25 mm. having trocar tip with dimpling on needle and fire ready indicator. 16 g & 10 cm in length, coil shape breast tissue marker with both front trigger & an alternate rear trigger, should be visible in ultrasound, mammography and mri, extension coiled tube with integr