Tender For supply of pt resin 3ph 3limb 6.6kv 3.3kv 110v 100v, part no.2267770 , relay e l 50a 1a 110v ac, part no.1902284 , rectifier bridge unit 60 63a 600piv 100v, part no.1925362 , mechanism catch 25ka, part no.1435292 , vtc closing coil 110 v dc, part no.2064613 , shunt trip coil 110 v dc, part no.2064674 , mechanism motor wound spring charged, part no.1435279 , switch auxiliary assly 8 way, part no.2120276 , idmt relay, part no.p0083 , anti pumping relay 11 pin 110v ac, part no.1901709 , bus bar spout 12oo amp, part no.mv3308 , interruptr assy.complet transfer flex., part no.1127006 , epoxy resin cast current transformer rat, part no.ba1132 , expoxy resin cast current transformer 20, part no.92720000 , insulator porcelain roof bushing, part no.1113379 , block contact 2no for pb, part no.0190275 , stud copper 1000a87c57 30 bush, part no.0238079 , vcb 11kv 1250amp mnl sprg elebely, part no.418535
Tender For 1. solid state over voltage relay for transformer rectifier unit of rmpu coaches. specn: specification no: drg. icf specification n0,icf/elect/897 rev.o or latest.;2. insulation monitoring relay 110 volt ac, range 50 v to 200 v ac insulation measuring range 25 kilo ohm to 100 kilo ohm, control supply-230 volts, 50 hz having fault memory test and reset button and alarm lead as per rcf specification edts-073 rev d amend 3. as per drg.no. nil specn: rcf specification edts-073 rev d amend 3;3. mpcb, current rating: 16 a, thermal release range: 10-16 a, class: 10, breaking capacity: 10ka, pole: 3 p, voltage rating: 415 v ac conforming to rdso spec. no. rdso/pe/spec/ac/0184 %u2013 2015 (rev. 0) as per drg.no. nil specn: rdso spec. no. rdso/pe/spec/ac/0184 %u2013 2015 (rev. 0)4. set of thermal expansion valve suitable for lhb rmpu ac unit of 3.5 ton-conforming to rdso spec:-rdso/pe/spec/ac/0061-2005(rev.-1) one set contains two valve. 1] sporlan-ebve :7/8
Tender For supply and installation of equipments of electrical machine lab for electrical engineering department at bit sindri, dhanbad, jharkhand - machines lab electrical engineering department, dc rectifier unit, dc motor three point starter, rheostat, rheostat, rheostat, three phase synchronous machine, dc shunt motor, three phase 6a auto transformer, digital stroboscope, control panel, dc shunt motor and dc shunt generator set, control panel, resistive load, three phase squirrel cage induction motor, control panel, three phase auto transformer, resistive load, bldc motor, one phase transformer, three phase transformer
Tender For supply of procurement of spares prabhu make flp lt ht starter dp and geb d d ? g? g - contactor complete 400 amps. 3. 3kv, part no. ht-200 , vacuum contactor rectifier bridge, part no. ht-201 , bottle for vacuum contactor 3. 3kv, 400 amps, part no. ht-202 , vacuum contactor closing coil 110v dc, part no. ht-203 , vacuum contactor holding coil 110v dc, part no. ht-204 , auxiliary switch for vacuum contactor 2no 2 nc, part no. ht-205 , p. t. 40va 0-8-12v 0-110v, part no. ht-206 , auxilary contactor 3 no 1 nc 110v ac, part no. ht-208 , resin cast p. t. 750va 3. 3kv 110 volts single phase, part no. ht-300 , h. t control fuse 3. 3kv, 2 amps, part no. ht400 , copper busbar 400amps set of three, part no. ht-101 , resin cast moulded c. t. for o l 3. 3kv, part no. ht-600 , dmc moulded 3. 3kv insulator for power fuse, part no. ht700 , push button with element for start, stop, test and reset, part no. ht--1300 , lamp holder with lamp for starter, part no. ht-1400 , brass cable gland complete with c. i clamp, stud , part no. ht-1600 , s t idmtl o c and s c r with time leg o l setting - 50 percent to 200 percent and s c setting 400 percent to 1600percent of flc, part no. ht-900a , e. l unit complete without transformer, part no. ht-800 , dmc moulded copper terminal 400a, 3. 3kv , part no. flp vcb 045 , isolator 100 amps reversing, part no. fs- 2 002 , air break contactor 40amps upto 20hp 550v starter, part no. fs- 2 003c , air break contactor 63amps upto 30hp 550v starter, part no. fs- 2 003e , auxiliary transformer 80va pri-500 525 550v sec-0-8-12, 0-110v, part no. fs- 2 004c , dmc terminal for i c ,t g,o g and partition 100 amps, part no. fs- 2 008 , dmc auxilary terminal, part fs2 009 , 3 pole magnetic o l relay type direct acting, part fs- 2 010 , direct acting thermal overload relay upto 30hp starter, part no. fs-2 010a , 65 sq mm ammeter ct operated, part no. fs-2 011 , 65 sq mm ammeter direct acting, part no. fs-2 011a , ct for ammeter, part no. fs-2 012 , short circuit hrc fuses 63 amps, part no. fs- 2 014e , auxilary contactor 2 no 2 nc 110v 415v 500v, part no. fs- 2 020 , pilot relay 12v dc, part no. fs- 2 026 , s e l r with cbct and p. t. el setting 50ma to 750ma with time delay 0. 1 to 1 sec in step of 0. 1 sec with test and reset micro switch and conc wire, part no. fs- 2 037 , isolator 200 amps reversing, part no. fs- 3 002b , isolator 300 amps reversing, part no. fs- 3 002c , air break contactor 185amps, fs- 3 003h , air break contactor 300amps, fs- 3 003l , air break contactor 325 330amps, fs- 3 003m , dmc terminal for i c and t g 300 amps, fs- 3 008a , dmc terminal for i c and t g 400 amps, fs- 3 008b , dmc terminal for outgoing partition 300 amps, fs- 3 009b , dmc auxilary terminal, fs- 3 010 , 3 pole magnetic o l relay type ct operated, part fs- 3 011a , ct operated thermal overload relay 4. 5 to 7. 5a with mounting kit, fs-3 011c , ct for overload relay,fs- 3 012 , 65 72 sq mm ammeter ct operated,fs- 3 012b , 65 or 72 sq mm voltmeter 0-600v, fs- 3 012d , pilot relay 12v dc, part no. fs- 3 026 , s e l r with cbct and p. t. e l setting 50ma to 750ma with time delay 0. 1 to 1 sec in step of 0. 1 sec with test and reset micro switch and conc wire,part no. fs- 3 041 25 amps contactor with 110v coil, part no. dpf-1 002a, hrc fuse base with carrier, part no. dpf-1 004, hrc fuse link,10 amps, part no. dpf-1 004a, e l. trip indication lamp, part no. dpf-1 006a, glass fuse. 1 amp, part no. dpf-1 007a, glass fuse. 2 amps, part no. dpf-1 007b, on off toggle switch, part no. dpf-1 008, incoming throughgoing dmc,moulded terminal with brass stud, part no. dpf-1 013, interconnecting dmc, moulded terminal with brass, part no. dpf-1 013a, condensor,16v,220 mfd. , part no. dpf-1 019, m 8 //bid details2 / 59