Web Analytics Made Easy - StatCounter

Diverter Plate Tenders

Get complete information related to latest Diverter Plate Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Diverter Plate Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Diverter Plate Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :39156162 Due date: 07 Feb, 202507 Feb, 2025 1.15 Lacs
Tender For supply of electric items as per annexure-d at giral lignite project, rsmml, ceu lignite office, barmer. - p & fixing powder coated crca sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes, din rail etc. as required 2.5 mm thick., providing & fixing of 240/415 v residual current circuit breaker (rccb) conforming to (ls:12640-1)/ iec 61008 -1 , rated 4 kv impulse withstand voltage truly current operated and shall operate on cbct mechanism, provision for pad lock min. operation 10,000 up to 63 a rating and 5000 for 100 a rating and minimum phase termination capacity of 35 sq.mm. rigid wire, ip 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. rccb 63 amp, 4 pole, providing & fixing of iso certified company made tp&n, 415 v ac-23a front handle operated switch disconnector fuse unit, cubical type, without metallic enclosure (for panel mounting), as per pwd specification for electrical works conforming to is/iec 60947-3 : 1999 in existing panel with hbc fuses including making connections with lugs, testing etc as required sfu (switch fuse unit), 63 amp, 3 pole with handle, providing & fixing of 240/415 v ac mcb with positive isolation of 10ka breaking capacity (b/ c/d tripping characteristic as per type of load and site requirement) 4 kv impulse withstand voltage, lsi marked is 8828(1996) / conforming to iec 60898-1 2002, iec 60947- 2, low watt losses, trip free mechanism, energy limiting of class 3 as per iec, minimum phase termination capacity of 35 sq.mm. ,conductor line load reversibility, ip 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 up to 20 a rating and 10,000 up to 63 a, 5000 for 80 a & above rating including making, connections, testin~ etc. as re_quired., single pole mcb 6a to 32 amp, double pole mcb 6a to 32 amp pipe earthing as per is:3043- 1987 with 3.0 mtr. long, 40 mm dia . ' b ' class g.!. pipe is: 1239 (part-1) 2004, equivalent to bs : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof polypropylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal. all as per pre approved by engineer in charge., providing and fixing 180 cm high fencing with angle iron post size 50x50x6mm placed at every 3 meters apart and 45cm in ground embedded in cement concrete 1:3:6 (30x30x60cm) corner and every 10th.post to the strutted with 50x50x6 mm angle iron provided with 6 horizontal lines and 2diagonals of g.!. barbed wire between two post fitted and fixed with g.!. staples including each works in excavation etc. complete., supply & laying following size earth strip in horizontal or vertical run in surface by means of earth strip dmc insulator including riveting/ soldering/ welding, jointing shall be done by overlapping and with 2 set of brass (for cu strip) / gi (for gi strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. all as per pre approved by engineer in charge. 25x3 mm copper strip 30mm x 6mm alum. strip, providing & fixing of iso certified company made lightning conductor finial as per pwd specification for electrical works as per is 2309-1989 made out of 25 mm dia.,300 mm long copper solid rod having single prong at top with 85 mm dia ., 3 mm thick copper base plate including holes etc. complete as required. all as per pre approved by engineer in charge. providing & fixing of recessed/surface mounting heavy duty enclosure made out from galvanized steel / crca sheet not less then 1.2 mm thick conforming to is-8623-1 & 3 / iec 61439- 1 & 3. powder painted complete with din rail making i

CTN :39094826 Due date: 17 Feb, 202517 Feb, 2025 NA
Tender For supply of stores for construction of assets - cement 43 grade opc packed in hdpe bag each 50 kg wt , coarse sand free from vegetation , coarse aggregate 20mm graded , coarse aggregate 40mm graded , coarse aggregate 40 to 63mm graded , stone for rr masonary less than 6 inch , water proofing compound , mild steel bars of size 6 to 8 mm dia , mild steel bars of size 10 mm dia , gi binding wire , self tapping screws for ppgi sheet in pkt 100 nos , 150mm length 12mm dia nut and bolt with washer , 75mm length 12mm dia nut and bolt with washer , ms hinges 100mm , synthetic paint enamelled any colour , red oxide primer , painting brush 3 inch , base plate , puf rivets , l type corner flashing of ppgi sheet for inner wall panel , u channel of ppgi sheet , silicon sealant best quality for metal roof repair in 300gm tube. , fdn bolt of size 12mm dia and 450mm long with washer , ceramic tiles of size 600 mm x 600 mm , white cement , peg set , curtain arrangement , distribution box 8 way , mcb spn 240 volts 32 amps , mcb sp 6 to 32 amps , pvc tape 19mm wide 5 m long , cable pvc insulated size 1.5 sqmm single core , cable pvc insulated electric cable 2.5 sqmm single core . , cable pvc insulated electric cable 4 sqmm single core , pvc casing capping 1 inch , pvc casing capping 3 by 4 inch , switch piano 5 amp 230 volts , led tuble light fittings 15w 230v , screw full thread 6 x 19 mm isi marked , pvc switch board snow white size 7 inch by 4 inch , pvc switch board 8 inch by 10 inch , pvcl and t bend , switch socket combination 15 amp 230 volts , switch socket combination 5 amp 230 volts , service bracket 40mm dia gi tubing , service cable pvc insulated aluminium 10 sqmm 2 core . , ceiling rose three terminal , led bulk head fitting , pvc flexible wire copper conductor multi stranded , pvc flexible conduit pipe 15 mm dia , pvc round or square block , exhaust fan 230 volts 200 mm , fire extinguisher of 1 kg of dry power type , earthing plate 600 x 600 x 6 mm , ci earth pit cover of size 300 x 300 x 6 mm , funnel fitted with 20 mm diameter gi pipe 1.5 m long. , gi wire 4 mm diameter for earthing. , charcoal , salt normal , air termination single pointed aluminium rod 12 mm dia and 300 mm long. , testing point terminal block , aluminium strips 25 x 3.0 mm . , galvanized iron strip 32 x 6 mm . , insulating pvc block 75 x 75 x 30 mm with insulating clamp nut and bolt , individual standalone plastic body smoke alarm , individual standalone plastic body heat alarm , fire ball extinguisher of 1.3 kg wt

CTN :39070078 Due date: 14 Feb, 202514 Feb, 2025 NA
Tender For custom bid for services - provision of standby pump and associatedworks at main water supply pump house at af station samana-1. supply, installation and commissioning of submersible pump set 30 hp having discharge of 1650-500 lpm and head 47-78m electric driven 415 v, tp suitable open well (outlet size for 80*65mm dia) supply and install complete inclusive of 20 meter long 25 sqmm 3 core flat submersible cable, chain for supporting and taking out set mounting arrangement. nos 01, 2. supply, install, testing and commissioning and testing factory made and tested (including cpri type test certified) lt feeder pillar box (kiosk) outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 hz ac supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars 350 amps rating installed on porcelain insulators. the panel shall be dust and vermin proof, made of 3.15mm crca ms sheet 75mm x 30mm thick ms channel frame, duly powder coated finish. front opening type with aprons for cable entry with double door shitter and locking arrangement, danger plate and earthing terminal. the scope of work includes pcc foundation and provision of the following :- incoming (a) mccb 4 pole 200 amps, 36 ka, 415 v - 01 nos (b) bus bar aluminum strip 400 amp, 4 pole, for in comp supply - 01 nos (c) digital panel meter including cts - 01 no outgoing (a) mcb tpn 40 amp 6 ka, 415 v 50 hz - 02 nos (b) mccb tpn 80 amp 16 ka, 415 v 50 hz - 01 no (c) star delta starter panel with suitable thermal overload protection, sppr, overvoltage, overcurrent and surge protection for 30 hp - 02 nos (d) low water level motor cutoff sensor with wire 20 mtr - 02 nos (make gic or slect control pvt ltd.). each 01, 3. supply and fix pressure guage upto pn-40 rating all as specified and as directed by engineer-in-charge. each 10, 4. supply and fixing hdpe pipe 90 mm dia pn 16 pressure rating with connected items all as specified and as directed by engineer-in-charge. rm 15, 5. supply and fix, gi sluice valve confirming to is 13095, 100 mm (4 ) dia with flanges end v all as specified and directed by engineer-in-charge., 6. material and labour in replacement for construction of valve chamber of size 1200 x 900 x 900 mm deep dimensions (over all internal dimension) for sluice valve etc. with pcc foundation, pcc block masonry walls, plastering, pcc coping, white washing, mild steel chamber cover, painting to chamber cover including excavation and earth work in any type of soil complete all as specified below :- valve chamber shall be provided with the following specifications :- (i) cement concrete for foundation (1:4:8) type d2 using 40mm graded stone aggregate 150mm thick extended upto 150 mm beyond the outer face of block masonry. (ii) walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20 mm graded stone aggregate) solid building blocks, setting in cm 1:6 complete. (iii) internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with cm 1:4 15 mm thick finished even and smooth. (iv) 50 mm thick coping in pcc 1:3:6 type c1 over block masonry wall. (v) entire plastered surfaces shall be treated with 3 coats of white wash. (vi) chamber cover shall be of 6 mm thick fiber reinforced polymer (frp) sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement. steel furface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer. each 01, 7. supply and fix 100 mm non return valve conforming to is 13095, 100 mm (4 ) dia with flanges end all as specified and directed. each 02, 8. supply and fix galvanized iron heavy grade pn 16 rating y section with flanged end 2 openings 100 mm dia and one 180 mm dia with suitable flanges and bots flanges end v all as specified and directed. kg 25-msme exemption - yes | startup exemption - yes

CTN :39070560 Due date: 14 Feb, 202514 Feb, 2025 NA
Tender For supply of medium living shelter of size 10.44 m x 6.10 m x 4.75 m height with 1.50 m enclosed verandah , cement 43 grade opc packed in hdpe bag each 50 kg wt , coarse sand free from vegetation , coarse aggregate 20mm graded , coarse aggregate 40mm graded , coarse aggregate 40 to 63mm graded , stone for rr masonary less than 6 inch , water proofing compound , mild steel bars of size 6 to 8 mm dia , mild steel bars of size 10 mm dia , gi binding wire , ceramic tiles of size 600 mm x 600 mm , white cement , peg set of six fitted with galvanised screws , curtain arrangement drapery and rod made of 25 mm dia , distribution box 8 way , mcb spn 240 volts 32 amps , mcb sp 6 to 32 amps , pvc tape 19mm wide 5 m long , cable pvc insulated of size 1.5 sqmm single core , cable pvc insulated of size 2.5 sqmm single core , cable pvc insulated of size 4 sqmm single core , pvc casing capping 1 inch , pvc casing capping 3by 4inch long , switch piano 5 amp 230 volts , led tuble light fittings 15w 230v , screw full thread 6 x 19 mm , pvc switch board 7 inch by 4 inch , pvc switch board 8 inch by 10 inch , pvc l and t bend , switch socket combination 15 amp 230 volts , switch socket combination 5 amp , service bracket 40mm dia gi tubing medium grade 1.5 mtr long , service cable pvc insulated 10 sqmm 2 core , ceiling rose three terminal , led bulk head fitting , pvc flexible wire copper conductor multi stranded , pvc flexible conduit pipe 15 mm dia , pvc round block , exhaust fan 230 volts 200 mm sweep , fire extinguisher of 1 kg of dry power type , earthing plate 600 x 600 x 6 mm , ci earth pit cover of size 300 x 300 x 6 mm , funnel fitted with 20 mm diameter gi pipe 1.5 m long. , gi wire 4 mm diameter for earthing. , charcoal , salt normal , air termination single pointed aluminium rod 12 mm dia and 300 mm long. , testing point terminal block , aluminium strips 25 x 3.0 mm . , galvanized iron strip 32 x 6 mm. , insulating pvc block 75 x 75 x 30 mm , individual standalone plastic body smoke alarm , individual standalone plastic body heat alarm , fire ball extinguisher of 1.3 kg wt , double sleeping bunk , steel bed side locker of size 1000mm x 1500x 450mm , study chair without arms 12 mm thick plywood , study table , water dispenser of 230 v 500 watts , protable indoor type high quality kero heater , looking mirror of selected quality

CTN :39025482 Due date: 10 Feb, 202510 Feb, 2025 NA
Tender For 3 x 120 sq. mm, 19/33 kv grade (earthed system), ht, three core power cable with improv ed fire performance category c2, stranded compact circular aluminium conductor complying with class 2 of is 8130, conductor screened with black extruded semi conducting compound, xlpe insulated, insulatio n screened with black extruded semi conducting compound in combination with copper tape, cores' iden tification by coloured strip applied on the cores, cores laid up, innersheath of pvc applied by extrusion, g alvanised round steel wires or galvanized formed wires armoured, and outer sheath of pvc applied by e xtrusion conforming to the requirement of type st 2 of is 5831 & also meet the requirement of c2 categor y tests under clause 19.1.3 & 19.2.1 , conforming to is 7098/ (part-ii) 2011 with amendment no. 1 & 2 and isi marked. (i) type test certificate conforming to is:7098 part-2 from nabl accredited lab has to be subm itted along with the offer and along with the supply of material as per clause 3.2 including notes {1 and 2( a,b,c)} of is 7098 (part 2) amendment no.-2. (ii) routine test certificate as per is:7098 part-2 has to be su bmitted along with supply of materials. (iii) acceptance test as per is:7098 part-2 has to be conducted by i nspection agency. [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up