Get complete information related to latest Duckfoot Bend Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Duckfoot Bend Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Duckfoot Bend Tenders.
Tender For corrigendum : supply of control valves for lara singrauli and talcher projects - lara-cv-asv-8, dea pegging from aux. steam header , lara-cv-crhv-6, dea pegging from crh line , lara-cvcdv-25, low load condensate control , lara-cvcdv-39, gsc min. flow recirculation , lara-cv-cdv65, cep-a min. flow recirculation , lara-cv-cdv-67, cep-b min. flow recirculation , lara-cv-cdv-69, cep-c min. flow recirculation , lara-cv-cdv-43, excess dump control , lara-cv-cdv-72, condensate for valve gland sealing and flash tank , lara-cv-cdv84, condensate spray for flash tank , lara-cv-cdv94, condensate spray for unit flash tank , lara-cvdrv-53, hph-9a normal drain to hph-8a , lara-cv-drv59, hph-9b normal drain to hph-8b , lara-cv-drv-56, hph-9a alt drain to flash tank , lara-cv-drv-62, hph9b alt drain to flash tank , lara-cv-drv-2, hph-8a normal drain to hph-7a , lara-cv-drv-8, hph-8b normal drain to hph-7b , lara-cv-drv-5, hph-8a alt drain to flash tank , lara-cv-drv-11, hph-8b alt drain to flash tank , lara-cv-drv-15, hph-7a normal drain to deaerator , lara-cv-drv-22, hph-7b normal drain to deaerator , lara-cv-drv-18, hph-7a alt drain to flash tank , lara-cv-drv-25, hph-7b alt drain to flash tank , lara-cv-drv-82, lph-5 normal drain to lph-4 , lara-cv-drv-85, lph-5 alt. drain to flash tank-b , lara-cv-drv-65, lph-4 normal drain to lph-3 , lara-cv-drv-68, lph-4 alt. drain to flash tank-b , lara-cv-drv-77, drip pump discharge control , lara-cv-drv-31, lph-3 alt. drain to flash tank-b , lara-cv-drv-48, deaerator overflow to flash tank-b , lara-cv-dmv-43, normal dm mu to hotwell , lara-cv-dmv-78, emergency dm mu to hotwell , lara-cv-asv-16, drain of aux steam from existing unit header to unit flash tank , lara-cvdmcwsg12, dmcw system for sg aux , lara-cvdmcw18, dmcw system for tg aux , lara- one fourth inch ss tubing -12 meter for each tag , lara- ss fittings for connection to air filter regulator- for each tag , lara- ss fittings for connection to air lock relayfor each tag , lara- ss fittings for connection to ia header isolation valve - for each tag , lara- ss equal tee - for each tag , lara- ss half inch npt m x one fourth inch od tube connector- for each tag , lara- commissioning spares gaskets and gland packing set for each valve , lara- valve diagnostic and configuration software , lara- cv test charges , lara- mandatory spares- pneumatic and electro hydraulic actuator assembly or equivalent item applicable for selected actuator type shall be provided, 1 no. of each type model and rating , lara- mandatory spares- diaphragms, o rings, seals etc.- 5 nos. of all types make etc. , lara- mandatory spares- solenoid valves if applicable - 1 no. of each type , lara- mandatory spares- smart positioners complete unit and accessories link assembly - 2 nos. of each type, model and rating , lara- mandatory spares- pneumatic air filter or regulator- 2 nos. of each type, make rating etc. , laramandatory spares- air lock relays- 1 no. of each type, model and rating , lara- mandatory spares- valve trim - including cage, plug, stem, seat rings, guide bushings etc. - 1 set for each type,class,size of control valve , lara- mandatory spares- gland packing- 5 sets , lara- mandatory sparesgaskets- 5 sets , lara- mandatory spares- cep recirculation valve trim which includes spindle with cone, seat ring, guide bush, cage- 1 set , lara- mandatory spares- cep recirculation valve soft parts i.e. gland packing, seals, orings, gaskets etc.- 3 sets , lara- mandatory spares- ss fittings for connection to air filter regulator- for each tag- 100 nos. of each type , lara- mandatory spares- ss fittings for connection to air lock relay- for each tag100 nos. of each type , lara- mandatory spares- ss fittings for connection to ia header isolation valve- for each tag- 100 nos. of each type , lara- mandatory spares- ss equal tee- for each tag- 100 nos. of each type , lara- mandatory spares- pneumatic air filter or regulator- 20 nos. of each type and model , laramandatory spares- v
Tender For supply of one set of ferrule fittings required for lhb coaches consisting of following: (1) street elbow 1 bsp (f) x 1 bspt (m) to drg no. icf/std 3-5-129 alt a item no.-4 qty.- 1 no (2) pipe nipple 1 bspt (m) x 15 0mm long to astm a312 schedule 80 ss-304 qty- 1 nos. per set. [ warranty period: 48 months after the date of delivery ]
Tender For corrigendum : supply of 1000 am g , stanchion type c 3 750 steel , stanchion type c 4 1000 steel , stanchion type c 4 1000 am g , stanchion type c 7 1000 steel , stanchion type c 7 1100 steel , stanchion type c 7 750 steel , stanchion type c 8 1000 steel , stanchion type c 8 1100 steel , stanchion type c 9 1000 steel , stanchion type c 9 1100 steel , ring lug steel sheet 26 , stanchion type c 1 1000 steel , guard rail without turnbuckle , guard rail 2600 mm , guard rail 3000 mm , guard rail with additional insulating link 3950 mm , guard rail with additionalinsulating link 4000 mm , guard rail with additional insulating link 4050 mm , guard rail with additional insulating link 4100 mm , guard rail with additional insulating link 4700 mm , guard rail with additional insulating link 5000 mm , guard rail with additional insulating link 5200 mm , guard rail with additional insulating link 5450 mm , guardrail without turnbuckle and without insulating links1000mm , guard rail with additional insulating link 4500 mm , guardrail without turnbuckle and without insulatinglinks1050mm , guard rail without turnbuckle 1500mm , guard rail 1700 mm , guard rail 2700 mm , guard rail 2800 mm , guard rail 2900 mm , guard rail 2950 mm , guardrail without turnbuckleand without insulatinglinks1100mm , guard rail with additional insulating link 3500 mm , guard rail with additional ins , guard rail 3350 mm , guard rail 3200 mm , guard rail with additional insulating link 4600 mm , guard rail with additional insulating link 4650 mm , rail , railing pipe 33 point 8 odx2 point 6 thk is 1239 part i 1979 , railing pipe 30 odx5 thk am g , plate b p h o 6 gost 19903 2015 by ct3c p 2 gost 14637 89 , ss wire 3 t 2 12x18h9t gost 18143 72 , 8 rigging chain with long link at both ends l equal to 380mm , 8 rigging chain with long link at both ends l equal to 430mm , 8 rigging chain with long link at both ends l equal to 500mm , round bar 30 gost 2590 2006by ctc3 p 4 gost 532 2005 , pipe o ts 25 to 6thusond gost 3262 75 , installation charges for the above fittings on board yard 1258 as indiciated in attached ta no h ta 141000 40 rev b dtd 14 08 2024 , cablestud for collapsible stanchion with height750mm with groundingpin steel , stay for collapsible stanchion height1100mm with groundingpin steel , guardrail without turnbuckle and without insulating links 1050mm , guardrail without turnbuckleand without insulatinglinks 1100mm , railing pipe 33point8 odx2point6 thk is 1239 part i 1979 , 8 rigging chain with long link at both ends l equal to 380 mm , 8 rigging chain with long link at both ends l equal to430 mm , 8 rigging chain with long link at both ends l equal to 500 mm , round bar 30 gost 2590 2006byct3 p 4 gost 532 2005 , pipe o ts 25 6000 gost 3262 75 , installation charges for the above fittings on board yard 1259 as indiciated in attached ta no h ta 141000 40 revb dtd 14 08 2024
Tender For supply of floor drain traps (q3) , waste fittings for washbasin and sinks as per is 2963 (q3) , sinks / wash basins - vitreous china as per is 2556 (part 4) (q3) , m - seal as per is 9197 (q3) , tower bolts (ferrous metals) as per is 204 (q3) , hasps and staples as per is 363 (q3) , curtain pipe, sider and mounting bracket (q4) , taflon tape as per is 14635 (q3) , wood screws (q3) , iron drill bid screw pack of 13 piece , dhaga , mortice lock 4 level 75mm , mortice lock 6 level 75mm , ss kitchen rack 36 by 36 by 10 inch , plate rack stainless steel 31 by 24 by 10 inch