Tender For supply of shade net house and green house repairing c c - insect net cover , shade net cover for net house roof 125 gsm , aluminum profile as per requirement , zinc coated spring for aluminum profile , frp gate , double laminated skirting fabric 160 gsm of 1. 5 mtr width n. s item , providing and fixing g i pipes hollow tubular pipe as per requirement 12 kg per 6 metre , sliding aluminium shade net with accessories shade factor of 50 percent , hdpe or pp weed mat minimum 125 gsm cutting to size and shape , 3 mm gi wire for cross supporting of roof and laying of aluminium shade net , pvc and cpvc pipe and fittings
Tender For providing and laying different dia. d.i. pipes for supply of treated effluent from dera mandi effluent line to jaunapur farm houses under ee(wb)-ii. nit-08
Tender For extension of raw water sources from kalantra onwards by way of laying of pipes under cdf of honble mla wagoora kreeri ( irfan hafiz lone ) for the year 2025-26
Tender For providing, manufacturing, supplying, conveying,lowering & laying of ms pipeline from dindoli wds tosai point and conversation of ci/di to ms pipes atvarious locations in south east zone (limbayat) of suratmunicipal corporation.
Tender For augmentation and strengthening of water supply system and laying of g.i. pipes for rising main and distribution system for various hostel under cskhpkv palampur in tehsil palampur distt. kangra h p
Tender For corrigendum : work of laying pvc pipes on st poles installed in the area of aspur devsara, patti and chilbila subdivisions under electricity distribution division, pratapgarh.
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim