Get complete information related to latest Earth Fault Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Fault Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Fault Relay Tenders.
Tender For bid to ras corrigendum : supply of acb testing calibration service , ammeter voltmeter meter calibration and testing , thermal relay testing and calibration , earthfaultrelay testing , over current relay testing , auxilliary relay testing , instantaneous relay testing , ht cable ir testing , lt cable and motor ir testing , rubber mat testing , vcb testing , calibration of multimeter , calibration of clampmeter , calibration of earth tester , calibration of megger , calibration of lux meter , calibration of fluke ir thermometer , battery load test 16 cells , battery load test 32 cells , transformer oil , transformer oil tesing and filtration , tramsformer ir pi test , tramsformer oti wti calibration , tramsformer dfra test , tramsformer partial discharge test , tramsformer sfra test , tramsformer tan delta test , transformer vector group test , transformer polarity test , dga test of transformer oil ) /bid number: gem/2025/b/6950854 * /dated: 01-12-2025 & & / bid document1 / 26
Tender For corrigendum : provisioning of electrical and mechanical eqpt against ber under ge 862 ews - supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 300 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type(m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 450 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earthfault protection(aa) standard fitting & accessories e.g marking plate, lifting lugs, ci rollers, earthing terminals, cable box including suitable platform as reqd on site complete all as as specified & directed., supply, installation, testing and commissioning of serve controlled voltage stabilizer (confirming to bis 9815 (part-1) 1994, reaffirmation 2019 latest version) three phase, four wire (rybn), 50 hz, naturally oil cooled, outdoor, unbalanced type, cooper wound, metallic body duly power coated with lifting hooks two nos, digital display type, relay free smooth and silent operation with 1st filling of transformer oil up to level having following specification:-(a) capacity 100 kva (b) type - suitable for unbalanced load and unbalanced input(c) input voltage -360v-480v, input frequency 50 hz (d) output voltage - stabilized at any deigned/ desired voltage 415/+-1% (e) rated frequency - 50 hz(f) wave form distortion - nil (g) response time - not to exceed 20 milli seconds(h) sensitivity - (+/-) 1% (j) rate of correction - not less than 6 volt/second between phase and neutral (k) efficiency - more than 95% (l) type of load - three phase, unbalanced type (m) metering - digital display voltmeter/ammeter with multi-functional meter (n) operating temperature - for indoor use upto max ambient temp + 55 c (o) dimmer rating - 150 amp (p) dimension of tanks - as per oem design(q) oil capacity- as per oem design , (r) class of insulation - class f (s) mode of operation automatic/manual (t) winding temperature rise - max 55 c (10 c above operating temp) (u) transformer oil -is 335 marked (v) core-crgo m4 grade/crno (cold roll grain oriented)/ (cold rolled non-oriented)(w) auto transformer (variac) -100 percent copper wound electrolytic grade(x) losses - as per is norms (y) power factor - not less than 0.95(z ) protection - (i) over load protections (ii) short circuit protections (iii) high/low voltage cut off (iv) by pass arrangement in case of emergency (v) single phase sequence change /phase fail protection (vi) earthfault protection(a
Tender For tender for repair and replacement of equipment at 33/11kv s/stn 2x5 mva sub -station dalhousie under electrical sub-division dalhousie. - 33/11kv s/stn 2x5 mva sub -station dalhousie under electrical sub-division dalhousie., complete overhauling of 4 outgoing feeder breaker trolley with repair & replacement of 4 nos. spring charge motors, tripping & closing coils , limit switch, indication bulb and other minor spare parts like lock spring, grease complete in all respect to make smooth opeartion of breaker., providing and fixing declo make spring, charge motor with gearbox and limit switch in 4 nos. breakers., providing and fitting of overcurrent & earthfaultrelay ashida 141c or cg 14n, providing & fixing of 3 mm 10% thick non-metallic, anti-static, fire retardant, low temperature resistant, acid/alkali resistant, high breakdown voltage min 33kv epoxy electric floor coating. coating conforming to class-c is 15652:2006. shall properly bond to the surface., providing & fixing digital ampere meter 30vdc rish dpm or equivalent.
Tender For tender for repair and replacement of equipment at 33/11kv s/stn 2x1.6 mva sub -station sihunta under electrical sub-division sihunta. - 33/11kv s/stn 2x 1.6 mva sub -station sihunta under electrical sub-division sihunta., complete overhauling of 33kv abb make outdoor breaker with repair/ replacement of various spare parts i.e. limit switch, cam,latch,spring, change, motor etc. complete in all respect., complete overhauling of 33kv abb make incoming 1 outdoor breaker with replacement of operating mechanism. tnc switch, limit switch etc. complete in all respect., rectifiaction of wiring in 2 no. c & r panel with rewiring and replacement of tnc switch etc. complete in all respect., providing & fixing of overcurrent and earthfaultrelay cgl make., providng and fixing of 11kv vaccum intetrruption in 11kv cgl make vcb breaker trolley., providing & fixing of 24 watt led street light with clamp fittings.
Tender For supply of 3 phase scr controller for constant voltage current card , high voltage and phase fail phase sequence reverse card rating 20va , charger dc under voltage circuit of solid state sensing type. rating. aux. supply 12v dc,actuating voltage 242v, resetting voltage 245v , load over voltage circuit of solid state sensing type. rating. aux. supply 12v dc rating actuating voltage 248v, resetting voltage 245v , battery dc under voltage circuit of solid state sensing type. rating. aux supply 12v dc rating actuating voltage 198v resetting voltage 220v , battery dc over voltage circuit of solid state sensing type rating aux. supply 12v dc actuating voltage 300v resetting voltage 296v , load dc under voltage circuit of solid state sensing type rating aux supply 12v dc actuating voltage 198v resetting voltage 220v , load over voltage circuit of solid state sensing type with aux. supply 12v dc actuating voltage 248v resetting voltage 245v , load earth leakage circuit imd of solid state sensing type , static annunciation circuit with accept, reset and test facilities,rating 12v dc , 3 phase full wave controller , filter condenser , circuit for dc contactor , 2 pole 2 way no off cam type auto manual mode selector switch , 3 pole 2 way no off cam type boost equalising mode selector switch , 2 c o plug in type auxiliary relay with base for above lamp,240v ac , 2 c o plug in type auxiliary relay with base for remote alarm contact, rating 12v dc , auxiliary contactors for float boost mode selection with add on block , 4 pole 2 way ac rotary changeover selector switch for ac incoming for 220v 80a charger rating 150a , 4 pole 2 way ac rotary changeover selector switch for ac incoming for 220v 60a charger rating 100a ) /bid number: gem/2025/b/7026551 * /dated: 20-12-2025 & & / bid document1 / 21
Tender For supply of upper pole assembly comp with all int parts inc vaccum interrupter_j717-15199 , lower pole assembly comp with all int parts inc insu. studs and term_j717-15099 , timer aux. supply 220v dc_j957-4215 , master trip relay_j479-744 , heavy duty power pack 3 phase_j479-749 , contact multiplication relay 220dc for spring charging motor_j9574186 , contact multiplication relay for 110v dc antipumping_j957-4187 , insulating stud assembly_3vc690073 , idmt relay complete two over current relay and one earthfaultrelay_j573692 , facia annunciator 8 window_j572-656