Get complete information related to latest Earthing Resistor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earthing Resistor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earthing Resistor Tenders.
Tender For corrigendum : supply of earthingresistor to rcf drawing no. lw71246, alt. c, confirming to rcf specification no. edts-101 rev.-c am-3 corr-9 [ warranty period: 30 months after the date of delivery ]
Tender For supply of part no. boca2dn1319 , vacuum interrupter part no. bev0053 , aux contactor with coil part no. boca2dn1229 , body bolt part no. al16 , vacuum contactor 3.3kv part no. bev006133 , thermal o by l relay ctr 75 by 5 range 30a-75a part no. 122t3075 , thermal o by l relay ctr 120 by 5 range 48a-12 part no. 122t48120 , ammeter 30 by 5 for lt starter part no. 130a030soslt , contactor part no. bo25 , brass terminal with nylon bushing part no. oba , vcb closing coil part no. 501000 , glass fuse holder part no. bogf , voltmeter 600v for tsu part no. 130v0600sotlt , aux. contactor part no. mcra040atn , ammeter part no. am , capacitance trip device part no. raptor , earth leakage 50-750m a part no. elm7la , neutral earthingresistor part no. boner , copper stud with dmc insulator part no. tic , hv bushing part no. httc , vcb shunt trip coil part no. 500500 , vcb limit switch part no. bolso5 , neutral moniotring relay with resistance part no. nrmr , ht bushing part no. htta33 , earth leakage relay 50-750ma with time l part no. elm7lats80m , control relay 110v part no. bo3r , current transformer 60 by 5, 15va part no. 12060515 , ammeter 400 by 5 for tsu-lt part no. 130a0400sotlt , ammeter for tsu ht side part no. 130a060sotht , potential transformer 3.3 kv part no. htptl1 , ammeter 75 by 5 for lt starter part no. 130a075soslt , hv bushing part no. httaf , earth leakage relay 50-750ma-2a dual part no. elm7dlas , 3ph transformer 3.3 kv by 500va part no. htptl33 , hrc ht pt fuse 6.6 part no. htptf6 , switch module part no. 133ml110a , snstv elr 50-300ma,w by vrbl time lag part no. elm10 , e l r 50-750ma and 750ma- 2a,w by time lg and bct part no. elm7dlats80m , incoming cable busbar to isolator b-ph part no. bin41 , incoming cable busbar to isolator r-ph part no. bin39 , incoming cable busbar to isolator y-phe part no. bin40 , resistance 100 ohms 10w part no. 139jb , ammeter part no. 130a060sotht , multifunction meter part no. 130e0e44596 , aux contactor 220v ac part no. boca2dn1229 terminal bushing with insulator dmc inco part no. t5, current transformer for o by l part no. 120300515, current transformer for o by l part no. 120100515, current transformer part no. lat2001005, 3 pole oil dashpot relay 400 by 5 part no. 122m3755753p, earth leakage relay 50ma-750ma and 750ma-2 part no. elm7dlats80m, pot. transformer 500va part no. pt33500, ht bushing part no. t33, vacuum circuit breaker part no. vulcan, isolator 400a part no. kie33, voltmeter part no. vmso65, ammeter 300 by 5 for vcb part no. 130a0300sov33, ammeter 150 by 5 for vcb part no. 130a0150sov33, ammeter 100 by 5 for vcb part no. 130a0100sov33, live line indication 3.3kv part no. hl18, distance piece part no. 110111, sealing box complete part no. s1, sealing box complete part no. s4, cover bolts part no. 000110h, brass cone part no. bobc, rectifier part no. boa6, potential transformer 80 va part no. ds1, ammeter 400 by 5 for acb part no. 130ao400soa, sensitive earth leakage relay 50-300ma w part no. elm7stwpt, push button actuator part no. 120022, resistance part no. 139geb, potential transformer 80va part no. ds1, glass fuse with holder part no. bogfh, switch module part no. 133ml70a, switch module part no. 133ml300a, switch module part no. //bid details 2 / 71
Tender For supply of different capacity dg sets : - servicing 15 20 kva , servicing 20 to 32 kva , servicing 32 to 62 kva , servicing of dg set above 62 point5 kva and upto 125 kva , servicing of dg set 125 to 160 kva , supply fixing fuel pipe diesel pipe along with benzo bolt on both side , supply fixing smps battery charger , supply fixing self starter unit , supply fixing charging alternator dynoma , supply fixing fuel pump calibration servicing , repairing of existing self starter , supply fixing avr for 3phase alternator , supply fixing diode 70 120 amp. , supply fixing stop solenoid assembly suitable for operation on 12 volts dc , supply fixing dg set starting switch with key set , supply fixing copper flexible cable approx 1 mtr in length , supply fixing v belts for engine , supply fixing hose pipe for radiator , supply fixing hour meter 415 vac 50 60hz counter type , supply fixing dg starting battery , supply fixing 12 volt 150 ah make battery , transportation of 15 20 30 kva ea set , transportation of dg set distance b upto 100 kms , transportation of dg set upto 150 kms , installation
Tender For tender for supply of drive shaft , tapper roller bearing , spring brake actuator , drag link rod kit , self starter bush , bushing , assy rear stopper suspension
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For supply of sleeve , piston ring set , head gasket , oil filter , head assy complete , small end bearing , big end bearing , tappet rocker assy set , self starter assy , avr card , cyl head stud , blower fan , 9 v battery rechargeable , 12v cell duracell , charger 9v multi , battery rechargeable , capacitor , rectifier , fan belt , bit key 30 , bit key 20 , woodruff key
Tender For corrigendum : supply of self starter motor 12v with 10 teeth on pinion for forklift engine similar to make : lucas tvs model no. 2sm114-12v. [ warranty period: 12 months after the date of delivery ]