Get complete information related to latest Educational Robot Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Educational Robot Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Educational Robot Tenders.
Tender For supply of service and re-calibration of lab equipments-, servicing and recalibration of universal testing machine (make: fsa, model: tue-cn1000, hydraulically operated, servo-controlled, capacity: 1000 kn with standard accessories: pc, printer, and ups):, , servicing and recalibration of compression testing machine (make : aimil, model: 317e-an- 2), three gauges of capacity: 500kn (gauge no. 145764), 1000kn (gauge no. 145765) and 2000kn (gauge no. 145766), , servicing and recalibration of mortar cube vibration machine (2 nos.) [make : aimil (model: aim-416) and universal soil equippers (model: cemt-11), , servicing and recalibration of flexural testing machine (make : aimil, capacity: 10t, gauge no: 79238) including oil change with servo 150 or equivalent, , servicing and recalibration of hot air oven (make : narang scientific works (nsw), model: nsw-143 (universal), capacity: 250c) including replacement of existing thermostat (maximum 250c, , servicing and recalibration of electronic weighing machine (make: hercules), capacity: 50kg (max)., , servicing and recalibration of electronic weighing machine (make: gramtech, model: gtk-500), capacity: 50kg (max). note: calibration certificate along with nabl certificate of the lab shall be submitted in triplicate. each 01 8. servicing and recalibration of electronic weighing machine (make: avery, model: a612w), capacity: 06kg (max). note: calibration certificate along with nabl certificate of the lab shall be submitted in triplicate. each 01 9. servicing and recalibration of electronic weighing machine (make: ming heng), capacity: 600g (max). note: calibration certificate along with nabl certificate of the lab shall be submitted in triplicate. each 01 10. servicing and recalibration of centrifugal bitumen extractor (make : benz instruments), electrically operated. note: calibration certificate along with nabl certificate of the lab shall be submitted in triplicate. each 01 11. servicing and recalibration of vicat apparatus (03 nos) (make : aimil) note: calibration certificate along with nabl certificate of the lab shall be submitted in triplicate. each 03 12. servicing and recalibration of digital vernier calliper (make : insize) note: calibration certificate along with nabl certificate of the lab shall be submitted in triplicate. each 01,
Tender For supply of laboratory and scientific equipment/tools - laboratory and scientific instruments/tools, compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r22, cooling capacity: 2355 kcal/hr type, voltage 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type: r134a, cooling capacity: 1411kcal/hr, voltage: 440vac, 25mfd, 1- phase (details as per sl. no. 1 at annexure-i)., compressor: type: refrigeration compressor, hermetically sealed, reciprocating, refrigerant type:r134a, cooling capacity: 0.25hp; supply voltage: 220-240 v ac, 1- phase (details as per sl. no. 1 at annexure-i)., capillary tube : 1.12 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.20 mm od, 8 ft, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 1.40 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., capillary tube : 0.95 mm od, material: copper astm b280 (details as per sl. no. 2 at annexure-i)., thermostatic expansion valve: orifice- 0 no., connection-1/2 x 3/8 flare (details as per sl. no. 3 at annexure-i)., thermostatic expansion valve: ten 068z3348, q-33311 r134a -40 to 10 ps 34 bar. (details as per sl. no. 3 at annexure-i)., hand stop /manual shut-off valve: media: r22, r502, r134a, r407c, r410a; port size: 3/8" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., hand stop /manual shut-off valve: media: media: r22, r502, r134a, r407c, r410a; port size: 1/4" sae; cooling method: direct cooling; power: manual; including brass material nut bolt. (details as per sl. no. 4 at annexure-i)., evaporator coil : 1/4" od, material: copper astm b280 (details as per sl. no. 5 at annexure-i)., condenser coil ; 3/8" od, material: copper astm b280 (details as per sl. no. 6 at annexure-i)., dimmer stat : 1500 w, 230 v ac. single phase, 50hz (details as per sl. no. 7 at annexure-i)., pressure gauge : connection 1/ npt 8 0 - 200 psi dial size 2.5" (63mm), connection sizes 1/4" (details as per sl. no. 8 at annexure-i)., digital temperature indicator : range -30 to 200 0c, power supply 230vac, digital display, accuracy 0.01 c channel -12 (details as per sl. no. 9 at annexure-i)., digital temperature indicator : type input cr-al(k-type), rang- 0 0c to 200 0c supply- 230vac, 50hz, channel -12 (details as per sl. no. 9 at annexure-i)., ammeter (digital) : rang 0-10 amp. single phase, digital display, 230v,10%vac (details as per sl. no. 10 at annexure-i)., voltmeter (digital) : rang 0 300-volt, single phase, digital display (details as per sl. no. 11 at annexure-i)., hp/lp cut out relay : hp- 8 to 32 bar, lp-0.2 to 7.5 bar, dual controls, 240 v, 50 va, single pole changeover switch (spdt), contact load 240 v ac: 8 fla, 48 lra (details as per sl. no. 12 at annexure-i)., energy meter : a.c. single phase, 2 wire solid state (static) fully electronic energy meter, accuracy class 1.0 & current rating 5-30 amp. with backlit lcd display for240 volt system fitted with pilfer proof meter box.(details as per sl. no. 13 at annexure-i)., r-134a refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; application: refrigerant; type of refrigerant-r134a. (details as per sl. no. 14 at annexure-i)., r-141b refrigerant gas : 5 kg filled cylinder; purity 99.9% appearance: colourless (details as per sl. no. 15 at annexure-a)., r502 refrigerant gas : 5 kg filled cylinder; acidity 0.00001 % appearance: colourless purity 99.9 % (details as per sl. no. 16 at annexure-i)., r407c refrigerant gas : 5 kg filled cylinder; appearance: colourless purity 99.9 % (details as per sl. no. 17 at annexure-i)., r-1234ze hfo refrigerant gas : 5 kg filled cylinder; moisture less than 0.001; purity: 99.9%; appearance: colourless; (det
Tender For supply and installation of physics instruments - c.r.o. dual trace 40 mhz: 1. type of input channels- analog and digital (mixed signal)2. number of analog channels-3. bandwidth - 300 megahertz.4. display type -colour tft.5. minimum display size- 10 inch.6. time base accuracy- 2.5 parts per million.7. sampling rate per digital channel simultaneously: 1gs/sec.8.record length per digital channel simultaneously- 8m point., function generator 0.3 to 3 mhz (scientific 10 mhz to 25 mhz frequency 1 channel function generator) : 1. frequency bandwidth (sine wave ) 10 mhz to 25 mhz.2. sample rate of arbitrary waveform generator (mega samples/sec)3. amplitude range (at 50 ohm impedance),10mv to 10 v pp. , multiplexers and de-multiplexer with built in power supply :1. material- abs2. display- digital, verification of de-morgen s theorem with built in power supply : 1. type- digital2. consisting of built in power supply3. logic ics connected internally for 1st & 2nd theorem.4. 2 logic input switches with indcators.5. 1 logic output indicator.6. 3 patch chords to connect input and outputs., encoder and decoder circuit with built in power supply : 1. material- pvc2. equipment materials - glass epoxy front panel with pvc3. temperature range- -5 to 45 celsius4. output voltage(regulated) : 5vdc (internally connected) , half adder, full adder, half subtractor, full subtractor with built in power supply: 1. built-in power supply dc +5 v at 500 ma.2. 3 logic input switches with green led display.3. 3 logic output red led display.4. two and gates ( 7408 ), one or gate ( 7432 )two not gates ( 7404 ) & two ex-or gates ( 7486 ) on panel., hall probe method for measurement of resistivity, complete with hall effect setup, hall probes, digital gauss meter, electromagnet and constant current supply. (complete apparatus) : 1. hall probe (ge crystal);(b)hall probe (inas).2. hall effect set-up (digital), dhe-213. electromagnet,emu-75oremu-50v.4. constant current power supply, dps-175 or dps-50.5. digital gaussmeter, dgm-102.6. range- 0-20 ma, apparatus to study characteristics of tunnel diode : 1. instrument comprises of dc regulated power supply of 0-600mv.1. two round meter for voltage & current measurement.2. circuit diagram is printing on front panel & important connections brought out on front panel.3. with well illustrated instruction manual, photo diode characteristic apparatus : 1. material- ms2. frequency- 50hz, photo transistor characteristic apparatus : 1. instrument type- analog2. input voltage - 220 v3. frequency - 50-60 hz, solar cell characteristic apparatus (complete apparatus) : 1. analog voltmeter: 12. analog ammeter: 13. solar panel/photovoltaic cell/solar cell to study characteristics: 14. range of dc voltmeter (in volt): 305. range of dc ammeter (in milli ampere): 506. necessary patch cords for interconnection7. along with instruction manual and demonstration, apparatus to study charging and discharging of a capacitor : 1. built in power supply : +12v variable & -12v, variable dc2. mains : 230v ac , ldr characteristics apparatus. : 1. voltage- 220 v2. apparatus type- analog3. temperature range- 50-60degree, plancks constant using solar cell : 1. instrument type- digital 2. built in power supply : +12v variable & -12v3. necessary patch cords for interconnection