Tender For tender for supply of soil investigation - consultancy services for digital topographical land surveying 9.97 acres by using electronic total station , showing all existing details like bldgs , fencing boundary wall , road and existing drain with invert level , existing main sewage line , spot level at 5.00m into 5.00m , and contour interval at 0.20m. marking of bm and tbm as directed by ge , marking of proposed area drainage , sewage disposal , road path culvert , external water suppluy , external electric supply , compound wall fencing gate and rain water harvesting and submission of drawings in autocad format 10 sets of colored drawings in soft copy in cd and 10 nos of data in hard copy in good quality paper approved by garrison engineer. , soil investigation of blgs to be carried out by a nabl accredited soil investigation agency govt engg college as per nbc is 1802 2131 2132 1888 2720 1904 6403 8009 1498 4968 and sp36. making bore hole of 150 dia upto 6 mtr depth below ground level collection of disturbed and undisturbed soil sample of an internal range of 1 mtr to 2 mtr performing spt at an interval of 0.75 mtr depth or at every change of soil starta which ever encounter first incl soil classification tests and bore hole of log data and evalution of safe bearing capacity and recommendations of type of foundations for suitability of earth obtain from foundation trenches including salinity test and chemical analysis of soil including following details. please see specification of document. , ditto- same as item no 2 above but depth upto 10 mtr or n value reaches 50 , whichever is earlier for isolated/combined/raft foudation.however depth of bore holes may be taken as 25 m for pile foundation. , ditto- same as item no 2 above but depth upto 15 mtr or n value reaches 50 , whichever is earlier for isolated/combined/raft foudation.however depth of bore holes may be taken as 25 m for pile foundation. , ditto- same as item no 2 above but depth upto 15 mtr or n value reaches 50 , whichever is earlier for isolated/combined/raft foudation.however depth of bore holes may be taken as 25 m for pile foundation.
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electricfencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electricfencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
Tender For supply of bhavan evm vidhut samagri - blau ret (ghanmiter), motiret (ghanmiter), gitti 20 mm (ghanmiter), gitti 06 mm (ghanmiter), cement bori, white cement, eet paki hui, dhula churi (ghanmiter), muram (ghanmiter(, pehwar block, loha angle vibhinn size me, colour coated chaddar 0.5 mm 4x12 feet, loha chaddar tin shade chaddar 4x16 feet me, loha patti vibhinn size me, loha sariya, loha pipe, ss machhar jali sq feet, rara wiron witer fencing chain link net for fencing mesh d fence wire 5 feet bundle linght:50 feet diameter:2.6 mm block size 4"x4 ., galvanized iron fencing angle 8 feet 5 inch (width), door kabja set, window chitakni, door holdrop, letrin sit may murga (indian), letrin sit may murga (western), urinal pot male, steel nal 1 inch, pvc nal 1/2 inch, pvc nal 1 inch, walve 1.5 inch, walve 2 inch, t 1.5 inch, gi pipe 1/2 inch (10 feet size), gi pipe 2 inch (10 feet size), gi socket 1/2 inch, gi socket 1 inch, gi socket 2 inch, gi elbow 1 inch, gi elbow 1/2 inch, gi elbow pon inch, gi elbow 2 inch, gi union 1/2 inch, gi union pon inch, gi union 1 inch, gi union 2 inch, riducer 2 inch, aashirwad pvc solvent, wall putti, rejmaal patta, tagadi, karni choti/badi, lakdi gutka, gaiti, darata, fawda, khurpi, gaiti/fawda dasta, iron keel (biranji), screw 1 inch, screw 2 inch, rawal plug, senting taar, deewar primer, iron primer, chuna putaai may material (prativarg miter me), oil paint putaai may material (pratibvarg miter me), distember putaai may material (prativarg miter me ), pani ki tanki (plastic) 1000 liter me, ashirwad cpvc picpes standerd quality 2 inch 1 pipe 3 miter, ashirwad cpvc picpes standerd quality 1 inch 1 pipe 3 miter, pvc joint socket 2 inch, pvc joint socket 1 inch, pvc point "t" 1x1/2 inch, pvc point "t" 2x1 inch, taflon tape, vidyut copper wire 2.5 mm (90 miter) prati bundle, vidyut copper wire 1.5 mm (90 miter) prati bundle, board five pin socket, board button, bulb holder sidha, bulb bad holder, holder board, round plate, 2 pin plug, 3 pin plug, fan regulator, mcb 32 a, mcb 63 a, mcb 200 a 3 fase, battrey/ ghadi cell, digital diwal ghadi, cutout 100 amp, cutout 65 amp, switch board (10 switches 1 sockets 1 indicator 1 fuse) 6 a three pin socket 9/11 board size, vidyut samagri fitting mistrii charge, electric taperoll 1 inch, pvc casing capping 1 inch, pvc casing bends left right 1 inch, casing patti, casing patti bend, ceiling fan copper rewinding 48 inch 1200 mm, ceiling fan condensor, led bulb 11 watt, led bulb 14 watt, led bulb 16 watt, led bulb 40 watt, led bulb 85 watt, street light may frame 20 watt, street light may frame 50 watt, street light may frame 60 watt, street light may frame 80 watt, led bulb rechargeble 12 watt, led bulb rechargeble 15 watt, torch rechargeble, electric tubelight, extension board, 16 amp power plug, finolex flexible copper cabels 4 sq mm 3 core, ceiling fan 1200mm, inverter 2 kva with batteries, electric exhaust fan, ups 1 kva, ups 2 kva, tester, plass, penchkas chota/bada, distilled water soor urja battrey hetu, submersible 7.5 hp texmo 8 stage three phase, submersible 7.5 hp texmo 8 rewinding, tubewell ke andar se motor nikalne avam punah dalne charge 400 feet, submersible pump 7.5 hp motor starter sj 3 phase mj1+series 280-415 (20-32 amps,7.5hp), aata chakki 14 inch pat ambri, aata chakki ke saft, aata chakki takai avam fitting charge, aatachakki ke belt, aata guthne ki machine ki saft, aata guthne ki machine ka belt, grease, gas chulha lighter, gas regulator nali 8 mm 4 kit, rv gas burner 3 feet, g-11 gas burner, gas converter, gas adapter high speed, gas coppertube 18", gas system marmmat mistri charge, vidyut saaj sajja charge (lighting gov. building charge per days), vibhagiya/rashtriya dhwaj bandhne ki rassi, maap inchi tape (measurement tape)
Tender For mud football court, drain, fencing, electric pole foundation, step gallery, toilet cum office building, inauguration stone, long jump pit, borewell, electrification works for toilet cum office building and street lighting works
Tender For provn of false ceiling and other connected works, bty charging room with electric fittings, chain link fencing around premised of repair insp bay parking shed and qm store, acs alongwith stablizer and water supply pipe line for reutilisation of exi