Tender For repairing work of the existing entire fire protection and detection system, supply and delivery of fire fighting items, and sealing of all electrical shafts with fire sealant at rampurhat gmchincluding chakmondala hostel campus
Tender For - arc of electrical material. - electrical work :, providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 10% humidity 10% to 90% rh working temp -5c to 45c . driver current 750ma. the luminaire shall be bis certified and trade mark certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , cri >70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . led street light fixture with minimum lumen output 5600 lm, supplying and drawing of xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt-4)/ 1994 and as per discom specs. on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required. all as per pre approved by engineer in-charge. for additional technical parameters of products/ work , refer annexure "a" attached with this bsr . 1 x 25 sq. mm. + 1x25 sq. mm. (insulated), supply and fixing of 11 kv pin insulator confirming to is:731:1971 with latest ammendment on existing bracket including all accessories like ms forged hot dipped gi pin confirming to is 2486(part-i)/1993 & is:2486 (part-ii)/1989 with latest amendment, and as per latest discom specs. etc. as required. all as per pre approved by engineer in-charge.for additional technical parameters of product / work refer annexure a attached with this bsr, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . c
Tender For supply of camera for cctv system (v3),led tv 32 inches,32 channel nvr dvr,16 channel nvr dvr,ups 1kva ups without battery,ups battery,coaxial cable,utpcat 6 outdoor cable,power cable,pvc pipe,gi pipes,6 u network rack,12 v power adaptors 4 amp,installation of l shaped angles iron brackets,supply of cage for protection of the camera with wire of suitable size,installation charges for fixing of pvc pipe on wall including cabling,installation charges,booster ballons,electrical cable junction box,ms erw pipe pole of 6 mtr height for fixing cctv,installation, commissioning and training,warranty and tech support for complete system,bis compliance,all miscellaneous items
Tender For corrigendum : providing minor repairs and protection work on tower no.- 134 of 132kv d/c transmission line kangoo-bijni-larji and kangoo bajoura under electrical system division hpsebl, bilaspur (h.p.)
Tender For supply of sitc of cctv access control and rf link with camc for ans facilities at puducherry airport c c -pair of rf link antennas along with lightning arrestors and other mounting accessories , ip based 2megapixel ptz dome camera with ip67 protection , ip based 2mp starlight ir ip h. 265 bullet camera with ip67 protection , 32 channel nvr with 4 sata and 40 tb storage 10 tb x 4 nos in raid 5 configuration , high end workstation for monitoring cctv and access control system , ip based access control devices and associated accessories , 24 port poe indoor managed switch with 4 x 1g sfps , 8 port poe 2x 1g sfp industrial grade managed switch , 16 port poe 2x 1g industrial grade managed switch , 8 port managed l2 network switch with sfp and populated ports and 4 x 10g sfps , floor mount 42u rack with accessories with 02 nos of power distribution units with 10 plug points each , wall mount 9u indoor rack with accessories with 02 nos of power distribution units with 05 plug points each , ip 55 rated 6u outdoor ip55 rack pole mount with rain canopy and accessories , cat6 utp patch cord of 1 meter length , 24 port jack panel fully loaded , indoor cat6 utp lszh cable , outdoor cat6 utp armored cable , sm 12 core armored ofc cable , 24 port liu with fully loaded lc connectors with accessories , lc - lc single mode fiber patch cord 3 meter , 3 core 2. 5 sq. mm armored power cable , 55-inch large format display 24 x 7 operations , camera pole of height 5 meters along with 8 nos of ip55 camera mount boxes , camera pole of height 12 meters for mounting rf antenna and camera along with 2 nos of ip55 camera mount box , 40mm hdpe pipe with required accessories , 25mm pvc electrical pipe with fixing accessories , high-end laptop for trouble shooting and network maintenance , excavation for laying of power and data cables and for mounting camera poles , installation testing commissioning and integration of above items from sl no 1-27 for complete cctv and access control system with rf link and existing ofc network , first year camc after warranty period , second year camc after warranty period , third year camc after warranty period
Tender For a/r & m/o of e&m service at abvims in dr. rml hospital, new delhi. (sh: supply, installation, testing and commissioning of automatic strontium nitrate based compact electrical equipment fire protection system subwork/packages:sitc of automatic strontium nitrate based compact electrical equipment fire protection system
Tender For corrigendum : supply of sitc of auditorium in national media centre pib c c - 200w led cct tuneable fresnel light having cob led source , 300w led profile spot 19 degree light having cob led source , aluminium o type clamp provided with fixture mounting 25mm m8 bolt and wing nut , dual safety chain made of gi wire bundled and twisted together , ms sheet electrical panel with 7 outgoing circuits , high quality power junction box having total max rating 10a, 250v a.c with 350meter frls copper 3 core cable , metal power junction box 2 way snap fit , high quality dimming in junction box 1 way , high quality dimming out junction box 1 way , dmx loop junction box having 1 no. of dmx 5 pin xlr , internal earthing system with copper bare conductors all along the cable trays , black powder coated cable trays , dmx male female connectors 5 pin with rubber sheath protection with 300 meter cable , dmx male termination connector 5 pin with resistor for signal defaming , dmxcontroller 12 faders with dmx 512 protocol , opto isolated rdm enabled dmx splitter unit , table top microphone with 600mm gooseneck microphone, supercardoid lobar , digital mixing console and ipad control , modular card based digital signal processor , 2-way high power loudspeaker , ptz auto framing camera with ai analytics , live switcher with 4 standards converted 3g-sdi inputs, 2d dve , sdi to usb for media converter , large format display fullhd , camera preview full hd led screen , motorized retractable mic and monitor , one eighth hdmi distributor , hdmi transmitter and receiver , 8 by 8 hdmi swticher , sdi cable and connerctor , central controller with touch panel , digital interactive podium , phonoconnectors , dismentling of existing cables and connectors , complete sitc of auditorium , system operator for av system, lighting etc for 3 years, 3 operator ) /bid number : gem/2025/b/6856971 * /dated: 20-11-2025 & & / bid document 1 / 30
Tender For corrigendum : supply of ball valve api 6d for c2 c3 pipeline project of gail c c-- enquiry document-mr, ball valves (api 6d), gen notes to mr, data sheet for eh ball valves (svs), data sheet for 14 inch ug ball valve -mov, data sheet for 14 inch ag mov, data sheet for 12 inch bw ag ball valve, data sheet for 12 inch mov, flg, ag ball valve, data sheet for manual 14 inch flg ag ball valve, data sheet-bw-manual-ug, data sheet manual-rb-flgd, data sheet-rb-flgd-se, data sheet-cryo-bw, data sheet-cryo-flgd, data sheet-lt service-fl, data sheet-lt service-flgd, data sheet-cryo-flgd, data sheet-utility, data sheet-lt service-rb-bw, data sheet, data sheet, specification for documentation requirement from suppliers, specification for quality management system requirements from bidders, blank format-form-b-b1-l-l1-s-s1, blank format-form-t, blank formats-form f-support foot details for ball valve, inspection and test plan for electro-hydraulic control value actuators, itp for electrical motor operated valve actuators, inspection and test plan for onshore ball valves (2, & above), specification for electrical motor operated valve actuators., standard specification for fire protection enclosure of valve actuator and accessories, standard specification for pipeline ball valves (onshore), technical notes for valves, vendor data requirements, vendor data requirement for ball valves, motor operated valve, motor operated valve, motor operated valve, motor operated valve, motor operated valve, job specification, job specification for esh actuator for sv valves, annexure-i to mr 9010
Tender For supply of electrical and electronics engineering lab equipments - switch gear and protection lab, control system & plc lab, energy conservation and audit & electrical measurement lab, ac machine lab, solar and wind power technology lab, electronic equipment maintenance lab (p2421404), antennas and microwave engineering lab (p2421502), automated control system and plc lab (p2421404), data communication and computer networking, lab (p2421601), embedded systems lab, industrial electronics
Tender For routine maintenance for 365 days - mtps-ii (1x600mw) – mechanical -ii circle - chp-ii – fire protection system – electrical-attending daily & routine maintenance works of electrical equipments such as battery and battery charger panels in fire water pump house, booster pump house and foam pump house, fire detection and alarm system along with battery & battery chargers, argonite flooding system and nitrogen injection system for transformers, ird & deluge valve system for conveyors and breakdown maintenance works on the electrical equipments of fire protection system with reprogramming erratic modules and providing new loop extension if required as well annual maintenance works on fire alarm panels for a period of 365 days from the date of taking over of site