Web Analytics Made Easy - StatCounter

Electric Machinery Scrap Tenders

Get complete information related to latest Electric Machinery Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electric Machinery Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electric Machinery Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :42964057 Due date: 19 Dec, 202519 Dec, 2025 9.32 Lacs
Tender For supply of electrical spares d d -dgms approved bis certified push button 550v 10a , dgms approved bis certified plug and socket assy 30a part no dpf1020 , motor protection relay part no bossr , idmt relay part no p0083 , ht bushing part no t33 , thermal overload relay part no 900b , single phase preventor part no ht2001 , pilot relay 12vdc part no dpf1015

CTN :42987091 Due date: 06 Dec, 202506 Dec, 2025 15.85 Lacs
Tender For dismantling primary and secondary ht lt cable by opening the terminal bushing taking out ht lt cable from each terminal again dismantling lt transformer 75 kva

CTN :42775090 Due date: 11 Dec, 202511 Dec, 2025 NA
Tender For corrigendum : dr. mvr rtpp-stage-ii-em&mrt- procurement of 6.6 kv ht motor/dry typet/f terminal bushing insulators- offer - req- reg.

CTN :42933062 Due date: 08 Dec, 202508 Dec, 2025 NA
Tender For tender for supply of job order for urgent repair of transformer of cap 400 kva at mil stn kalka : : - disconnecting ht and lt supply taking down the defective transformer indoor outdoor type from four pole two pole structure or lifting from the outdoor type foundation or taking out from sub station bldg using a crane of suitable capacity and slings ropes etc as required and shifting the same to civil workshop for repairs complete all as directed for transformer capacity 400 kva , shifting back the repaired transformer indoor outdoor type from civil workshop to site reinstalling at original position and fixing properly on four pole two pole structure or outdoor type foundation or inside a sub station bldg using a crane of suitable capacity and slings ropes etc as required making ht lt side connections and testing for satisfactorily working complete all as directed for transformer of capacity 400 kva , draining out transformer oil from the transformer and storing the same in suitable containers to be arranged by contractor without any extra cost opening the top cover and lifting up the core assembly carefully to check the condition of transformer windings and core retanking the same after repairing checking of leakage from transformer body and repairing welding works required for making transformer body leak proof refilling the transformer oil dully dehydrated and filtered dehydration and filteration to be paid separately and making all connections with ht lt side bushings refixing the top cover and testing the transformer with a suitable capacity insulation tester complete all as directed for transformer of cap 400 kva , m and l for rewinding of burnt out defective ht copper coils with new super enamelled heavy duty copper winding wires of size matching to the existing one including varnishing drying in a suitable oven and all insulating material such as cotton sleeves tapes etc and connections with bushing terminals complete all as specified and directed , all as per item no 4 above but lt copper coils complete all as specified and directed , m and l for painting the transformer tank from inside with two coats of zinc chromite after preparing the tank walls bottom top cover inner side by properly cleaning the surfaces oil free complete all as directed for transformer capacity 400 kva , m and l for replacement of defective ht porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , m and l for replacement of defective lt porcelain bushing of suitable size for transformer of cap 400 kva including washers of good quality complete all as specified and directed , dehydration and filteration of transformer oil for indoor outdoor type transformers of any capacity at site using transformer oil filteration plant to improve di electric strength not less than 45 kv at 2 point 5 mm electrode gap complete all as directed note unit rate quoted shall be deemed to include the charges for hiring of oil filteration plant shifting to different locations at cantt area testing of samples of oil as per requirement and nothing extra will be paid on this account , s and f new transformer oil for replacement or topping up the level of oil having dielectric strength not less than 45 complete all as specified and directed

Central Government/Public Sector

CTN :42938222 Due date: 06 Dec, 202506 Dec, 2025 10
Tender For tender for supply of 60watt led flp light type well glass , lamp led 240v 12 watt , fixt light 230v 18watt led tube light screw , lamp led 240v 18 watt , fixt light 230v 18watt led tube light screw , h.t. fuse for p.t 11kv switch 5v. , lt voltage detector non-contact range 30v 650v , insulator spout bushing 11kv/400a for 11kv ht switch , auxiliary tripping relay for 11kv ht switch type jrv-171 single phase aux supply 110v 1pole or equivalent. , switch cum out selector 110v for 3.3kv h.t. switch , fixed contact assy 400 amps 2450560 , moving contact 400 assy 2450980 , insulator spout bushing 11kv/400a for 11kv ht switch , shunt trip assy 230v/110v ac p.no.- uss016 , vcb closing coil (501000). , heavy duty glass fibre / frp highly insulated , selfsupporting type ladder with platform at top height- 6 feet. , suit , arc flash 8cal/cm2 size-xl , moving contact with terminal for ocb switch. lt5551c , fixed contact assy. 200amp. for ocb switch , 453201 , no volt coil assy. bt 1870s/ st1870s , insulation tester digital meggar tester type digital megger measurement range 5 kv , digital clamp meter 0- 1200 amp. 0-1000 amp. ac/d digital , kit spare mnx 400/300 amp or equivalent. , isolator 600 amp. 3 pole complete off-load , mccb 100a , type lm 100c ge power control , , crimping tool hand operated 10-185mm2 , power contector complete set , 2no + 2nc , 25 amps coil or equivalent , barrel pump hand operated rotary type suitable for 210 ltr. drums , 3 pole power contactors type mnx complete set , 650 amp , 2no + 2nc , 415volt coil voltage or equivalent

corporations/Associations/Others

CTN :42795133 Due date: 01 Dec, 202501 Dec, 2025 NA
Tender For supply of sea wire 14 and dt ht brass bushing rod 0.5 inch - supply of sea wire 14 & dt ht brass rod 0.5 inch as per respective specfications

Central Government/Public Sector

CTN :42460864 Due date: 01 Dec, 202501 Dec, 2025 28.00 Lacs
Tender For corrigendum : rep and maint to trnsfrmr, dehydration of trnsfrmr oil, capacitors, painting, ht bushing etc rep to ht over head network and rep/ replacement of ht ug cable, 4 pole/ 2 pole str, god, do fuse and ht poles, cts etc and connected wks at mil stn kannur

State Government

CTN :42897816 Due date: 04 Dec, 202504 Dec, 2025 9.90 Lacs
Tender For labour work for tender for supply,providing,fixing and installation of vertical boots for ht and lt bushing of transformer under limbdi town sdn. under limbdi division

State Government

CTN :42897818 Due date: 04 Dec, 202504 Dec, 2025 9.90 Lacs
Tender For labour work for tender for supply,providing,fixing and installation of vertical boots for ht and lt bushing of transformer under limbdi rural sdn. under limbdi division

State Government

CTN :42897921 Due date: 04 Dec, 202504 Dec, 2025 9.90 Lacs
Tender For labour work for tender for supply,providing,fixing and installation of vertical boots for ht and lt bushing of transformer under doliya sub division under limbdi division
 Loading, Please wait...

Connect us via What's Up