Tender For repair/maint and improvement of lt distribution network, lt panel, fp box and other allied works in sector a and sector b otm and md accn in army area under ge (a) no.1 jodhpur
Tender For 1. estt. for replacement of damage & burnt with detoriated incoming lt cable with distribution box of 100 kva distribution transformer for facilitation of smart dt metering under bhilai town zone, city division east bhilai, 2. estt. for replacement of damage & detoriated incoming lt cable of 200 kva distribution transformer for facilitation of smart dt metering under bhilai town zone, city division east bhilai, 3. estt. for replacement of damage & detoriated incoming lt cable with distribution box of 100 kva distribution transformer for facilitation of smart dt metering under bhilai town zone, city division east bhilai, 4. estt. for replacement of damage & detoriated incoming lt cable of 200 kva distribution transformer for facilitation of smart dt metering under bhilai town zone, city division east bhilai, 5. estt. for replacement of damage &short-length incoming lt cable of 63 kva distribution transformer for facilitation of smart dt metering under bhilai town zone, city division east bhilai (sch-028).
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 of is 1180 (part 1). terminal agreement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is to beprovided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : supply of lt switchgear for ntpc khavda solar pv project e e - 1st lot icr auxilary power distribution box outgoing 16 no 2p 6a mcb 3 no 2p 20a mcb 1 no 2p 10a mcb as per sld and specification , 2nd lot icr auxilary power distribution box outgoing 16 no 2p 6a mcb 3 no 2p 20a mcb 1 no 2p 10a mcb as per sld and specification , 3rd lot icr auxilary power distribution box outgoing 16 no 2p 6a mcb 3 no 2p 20a mcb 1 no 2p 10a mcb as per sld and specification , 4th lot icr auxilary power distribution box outgoing 16 no 2p 6a mcb 3 no 2p 20a mcb 1 no 2p 10a mcb as per sld and specification , 1st lot icr ups power 3kva 1 ph in 1 ph out distribution box incoming 16a 2p mcb outgoing 25 no 2p 6a mcb as per sld and specification , 2nd lot icr ups power 3kva 1 ph in 1 ph out distribution box incoming 16a 2p mcb outgoing 25 no 2p 6a mcb as per sld and specification , 3rd lot icr ups power 3kva 1 ph in 1 ph out distribution box incoming 16a 2p mcb outgoing 25 no 2p 6a mcb as per sld and specification , 4th lot icr ups power 3kva 1 ph in 1 ph out distribution box incoming 16a 2p mcb outgoing 25 no 2p 6a mcb as per sld and specification , cmcs ups power 6 kva 3ph in 1ph out distribution box incoming 32a 3p outgoing 2 no 2p 20a mcb 4 no 2 p 6a mcb as per sld and specification
Tender For corrigendum : new installation & replacement of 1ph & 3ph meter, service, mmb, and also new installed and replcement of 1ph & 3ph solar meter, new dropper on lt pole & 1 phase refitting work, distribution box on tc and dt meter work under shapar sdn under rrd
Tender For purchase of 40 kva, 3 phase aluminium wound energy efficient leve-1 completely self protected (csp) distribution transformers with provision of lt bushing box
Tender For repair/fittings/fixments/maint and replacement of internal electrical, distributionboard including wiring in offr mess, jco mess and central institute (2nd call)
Tender For corrigendum : 38/edcb/2025-26 - for supply and installation of single phase lt fuse set installed in smc box for 10 & 16 kva distribution transformers on turn-key basis under edc, budaun in business plan 2026-27.
Tender For estimate for replacement of 5 nos transformer distribution box at various location under scz of raipur under of city central dn. cspdcl raipur. 76-028-5160-2025-0006 dt. 30.03.26. r60028250661. (o&m-06-i)estimate for shifting of 01 no. lt pole applied by mrs. kalpana sohney at awanti vihar shankar nagar raipur under shankar nagar zone of city dn. (east) raipur. 78-035-5145-25-0048 dt. 16.01.26. r45035250855. (d/w-06-i)