Tender For electricalinstallation work such as special repair to ei to principals chamber, lecturers common room, library, laboratory and toilet etc. ei to additional section, ei to sf of ac machine, panel board and cable of college of teacher education, balangir
Tender For supply of various size of di- electrical safety shoes, electric shock resistant up to 30 kv as per attached specification. technical specification for art 9721w product: 30kv dielectric boot with steel toe. 1). size range : 5-11 2).type of construction vulcanized rubber upper and sole. 3).last/ sole pattern psv & vsv/ st 4).specialty tested individual boots at 30kv under wet condition 5).recommendation for working environment with high voltage hazards power station operations substation (step-up/ step-down/ distribution) operations electrical hazards with wet condition/ water exposure high current leakage hazards electricalinstallations. 6). compliance- astm f2413-18 m i/c eh european standard ce approved en iso 20345 :2011 (sb e fo hro sra) en 50321-1:2018 class 3 ac (for installations with nominal voltage up to 26500v a.c. sb = standard basic protection as per en iso 20345 e= heel energy absorption fo = fuel oil resistantoutsole hro = resistant to hot contact sra =slip resistance on ceramic tile with sodium lauryl sulphate csa z195-14 / astm f 2413-18 grade 1 toe protection compression resistance, 11kn 18 kv electric shock resistance (esr) protection. 7). dielectricfootwear* astm f1117-03(2013) (min 20,000vac) 8). lining material selected polyester grade lining comes with extra comfort and durability 9). upper construction leak-proof (electrically verified)reinforced rubber upper high visibility with orange and green contrast easy for cleaning. 10). sole / heel electrical shock resistant sole suitable for high voltage/ current environment slip resistant vulcanizedrubber outsole good abrasion resistant for extra durability heel energy absorption design tominimize the heel impact. 11). steel toe cap epoxy coated toe caps for anti-corrosion meets csa z195 impact andastm f2413 compression tests. 12). chemical resistance sole & upper - good resistant towards acids and alkalis 13). finishing lacquer coating for weather protection. 14). packing recyclable polybag & 6pairs in a carton. various sizes of electrical safety shoe as per requirement (size 6-11 as per attached chart) [ warranty period: 12 months after the date of delivery ]
Tender For annual maintenance of electricalinstallations in mch building annual maintenance contract to e1 general electrical work in govt medical college thrissur
Tender For operation and comprehensive maintenance of pumps, compound light and common area lighting including call basis maintenance of electricalinstallation of bsnl staff quarters at anna nagar, chennai
Tender For internal electricalinstallation and wiring of newly constructed administrative building including supply of all materials at barasat 220kv s/s under barasat area office, wbsetcl as per schedule
Tender For camc/amc shall include routine inspection, preventive maintenance, servicing, testing, cleaning, troubleshooting, fault rectification and breakdown support for hvac/vrv systems, fire alarm pa systems, cctv systems, epabx systems, electricalinstallations, it infrastructure and av systems including all associated equipment, panels, controls, cabling, accessories and minor consumables to ensure safe, reliable and uninterrupted operation as per oem recommendations