Get complete information related to latest Electrical Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrical Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrical Meter Tenders.
Tender For supply of instrument meters devices for basic electric lab bid - rheostat , dc supply , single phase dimmerstat , three phase dimmerstat , digital wattmeter , digital dc ammeter , digital ac ammeter , digital ac voltmeter , digital dc voltmeter , regulated dc supply or rectifier , contactless techometer , basic logic gates , dc motor , induction motor , starter
Tender For providing and fitting of essential items and allied material for snow clearance operation at nathatop sanasar road - supply, testing and commissioning of 48v smps float cum boost automotive battery charger with moveable trolley stand for snow operation at nathatop - sanasar roadgeneral technical requirements for battery charger suitable for 48v vrla type battery1.) type -float & float cum boost charger for vrla type, full wave, full controlled type. 2. ) ratings- 15 a float cum boost for 48v, 150 ah vrla type battery 3. ) ac input- i) voltage 415 vac 10%ii) frequency 50hz 5% iii) phase 3 - phase 4.) d.c.output voltage settings -nominal float fc 48/54.5v (adj. by + 20%, - 5% bc 48/66.5v (adj. by + 2%, - 5%) 5.) output current limit 15a 15a 6. ) power conversion ac to dc by means of three phase full wave, half controlled bridge rectifier consisting of thyristors and diodes. 7.) voltage regulation at bridge output. + 1% of set value for + 10% input voltage variations, 0-100% load variation. 8. ripple voltage less than 3% rms without battery connected. 9. efficiency more than 80% at full load 10. protections (a) input side ac input mccb & elbs with input on/off switch and fuses, contactor (b) output side dc output mccb with output on/off switch and fuses. (c) protection current limit protection, soft start feature, surge suppressor. fast semiconductor fuses for rectifier bridge. (d) control circuit fuses (e) capacitor circuit rectifier hrc fuses. (f) over-voltage cut-back (g) charger over load / short circuit (h) blocking diode 11. controls and switches followings controls and switches are provided in the system 1 ac input source mccbs with interlocking 2 dc output mccb 3 auto/manual float/boost mode selector switch. 4 float and boost voltage variable potentiometers. 5 manual voltage adjustment potentiometer 6 test push button 7 reset push button 8 battery current adjustment potentiometers 9 heater s power supply switch 12. features the following features are provided in the systems: 10 soft start on dc side 11 class-f insulation for all magnetic 12 automatic voltage regulation. 13 automatic changeover from float to boost and vice versa based on current, drawn by battery. 14 filter circuit to eliminate ripple. 15 charger current limit 16 separate battery path current limit. 17 built-in auto phase reversal of operation. 13. meters f.c. b.c. (i)input voltmeter (i) common (ii) input ammeter (ii) input ammeter (iii) output voltmeter (iii) output voltmeter (iv) output ammeter (iv) output ammeter. battery volt meter battery ammeter earth leakage ammeter 14. indications phase on lamps (ii) output on lamp a)phase on lamps (ii) output on lamp. (iii) charger on float led (iv)charger on boost led. 15. annunciation with audiovisual alarms. (i) ac input mains failure (ii) input phase failure (iii) ac under voltage iv) input phase failure v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped xiii) charger over load xiv) earth leakage xv) dc earth fault xvi) alarm supply fuse failure xvii)battery low condition. v) rectifier fuse failure vi) output fuse failure vii) filter fuse failure viii) dc under voltage ix) dc over voltage x) charger trip xi) capacitor fuse fail xii) output mccb tripped. note : all the alarms shall be provided through electronic display cards. audio alarm through buzzer, visual indication through 10 mm leds & alarm ackn. / reset and led provision is through push buttons. 16. operating ambient temperature surrounding the panel 00 to 500 c 17. surrounding the panel relative humidity. 0-95% non-condensing 18. panel (i) protective grade (ii) cooling (iii)paint ip 42 natural air-cooled smoke grey of iss-692 shade a) average winding temperature rise over ambient temperature b) insulation class c) insulation breakdown voltage. as per relevant iss. f 3 kv for 1 min withstand. 19. cables 1100 v
Tender For digital ammeter with led display, size 96 mm x 96 mm, multiline for measuring current r,y & b, 0-600 amps ac , ctr, 1a / 5 a programmable, with aux. supply 24 / 110 v dc, 4 va, class 1make acce ptable: l & t, ae, socomec, siemens, schneider, yokins, rishabh.the meter shall be supplied along with c alibration certificate traceable to nabl standard. [ warranty period: 12 months after the date of delivery ]
Tender For supply of digital milliohmeter , thermometer , ramp tester , insulation tester , true rms dmm , dc volt meter , dc ampmeter , digital multimeter , digital insulation tester , pressure tester gauge , suction gauge , dps450 air data test set , altimeter , air speed indicator , vertical speed indicator , dc volt meter , dc ammeter , ac volt meter , ac ammeter , thermo hygrometer , stop watch , torque screw driver , micro ohm meter , dc power supply , multimeter fluke , alpha battery charger concord , battery discharger concord , torque wrench , hygrometer
Tender For supply of load ammeter range - 0 -1000 a dc, fsd - 75 mv, size :144 x 144 sq mm with exte rnal shunt, 1000 a/75 mv for n.g .loco zdm4 [ warranty period: 30 months after the date of deliv ery ]
Tender For corrigendum : supply of 11 kv 24 panel switch board - design engineering manufacturing shop testing inspection packing delivery to site of 11 kv switchboard , spare incomer breaker with trolley and 3 phase line pt mounted , spare outgoing breaker with trolley of each size and rating , numerical feeder protection and control relay of each type , numerical transformer differential protection and control relay of each type , single phase current transformer for each type and rating , single phase current transformer for differential protection for each type and rating , pt primary fuse of each rating , pt secondary fuse mcb , spring charging motor , surge arresters , tnc control switch , closing coil , tripping coil , ammeter selector switch , voltmeter selector switch , bus support insulator used in bus bar compartment of each type , bus support insulator used in cable compartment of each type , anti pumping relay , dc failure relay , master trip relay , 24 window annunciator , 10 window annunciator , hooter , led indication lamps 110v dc for each colours red yellow biue green clear white amber , led indication lamps 110v ac for each colours red yellow and biue , service test limit switches of each type and rating , limit switches used in vcb of each type and rating , electrical contact grease , installation and commissioning support as per engineering specification cd css 11kv sb es.