Tender For electrical supply to the prefabricated shops in b-type parking - mcb, elcb, rccb, db and rcbo. (db should be same make)., lt panel/board, feeder panel., lt cable, 1.1 kv grade., frls wires &cable, 650v/1.1 kv., grade, switch, socket, faceplate, gi box., rgb, beam light., digital 1-0/3-0 energy meter., ip65 energy meter box., brass compression gland., telephone cable., cable lugs & thimble., telephone tag box., pvc conduit and accessories., ms conduit and accessories., cat-6a cable, cable raceway and accessories., led light luminarie, timer & contractor, i/o (data) port, indication lamp & push button, mcb metal enclosure, wall fan heavy duty, dwc pipe, pvc junction box, fastener, pole street light, led light fixutre, splitte box, split ac
Tender For corrigendum : ridf xxviii - lift irrigation projects in various padashekharams of wayanad district- procurement of submersible pumpsets, fittings, accessories, and related electrical works - procurement, installation, erection, testing, and commissioning of pumpsets and allied works at punchavayal, manikkuni, kolembetta, valiyavattam, and padiyeri pumphouses. - procurement, installation, erection, testing, and commissioning of pumpsets and allied works at punchavayal, manikkuni, kolembetta, valiyavattam, and padiyeri pumphouses., supply, installation, erection, testing, commissioning and fitting charges for all accessories of horizontally mounted submerged centrifugal non clog pump set of compact unitary mono-block submerged single/multi stage,volute type casing with suitable radial type impellers on common shaft for pump and motor ,anti friction bearing with life time greasing, protection features with sensors to monitor temperature,mechanical seal leakage ,etc.(the pump should be confirming to his/is standards).the moc of pump,casing-cast iron,impeller -ss cf8m,shaft-ss-316,suction strainer -ss and other as per is standard.the motor should be suitable for 3 phase,415v /-10%,50hz /5%,ac supply submersible motor having class f /h insulation, air filled and ip-68protection confirming to is 325 or latest standards suitable for day night operation.the pump discharge capacity of 230 cubic metre /hour against duty point head of 42 mtrs, working head range 18 - 47m, discharge range 136 - 57 lps ,speed 1450rpm(n) or nearer ,with 10meters of copper power cable and control cable, railing arrangement. the pump should be painted with three coats of suitable anti corrosive paint over priming coat. the electrical works for the pumpset should be completed as per kseb rules and regulations and the contractor is responsible for arranging premissions and certificates from the electrical inspectorate. the suction side of the pumpset should be provided with an additional iron grill for preventing foreign particles inside the inlet side of the pump casing., supply and erection of 60hp auto transformer starter (ats) with suitable incommer and contactors including 24 kvar capacitor with required indications ,metering and protections for single phasing ,overload, pump monitoring unit to protect from ingress, high temperature level etc enclosed in a closed panel board, supply and laying additional termination cable of 1.1kv 3.5 core 95sqmm aluminium conductor xlpe insulated ;steel armoured ug cable as per relevant is 7098 with support for cable, supply, installation, erection, testing, commissioning and fitting charges for all accessories of horizontzlly mounted submerged centrifugal non clog pump set of compact unitary mono-block submerged single/multi stage,volute type casing with suitable radial type impellers on common shaft for pump and motor ,anti friction bearing with life time greasing, protection features with sensors to monitor temperature,mechanical seal leakage ,etc.(the pump should be confirming to his/is standards).the moc of pump,casing-cast iron,impeller -ss cf8m,shaft-ss-316,suction strainer -ss and other as per is standard.the motor should be suitable for 3 phase,415v /-10%,50hz /5%,ac supply submersible motor having class f /h insulation, air filled and ip-68protection confirming to is 325 or latest standards suitable for day nightoperation.the pump discharge capacity of 188 cubic metre /hour against duty point head of 35 mtrs,working head range 16 - 42m, discharge range 102 - 42 lps ,speed 1450 rpm(n) or nearer ,with 10meters of copper power cable and control cable,railing arrangement. the pump should be painted with three coats of suitable anti corrosive paint over priming coat. the electrical works for the pumpset should be completed as per kseb rules and regulations and the contractor is responsible for arranging premissions and certificates from the electrical inspectorate. the suction side of the pumpset should be provided wi
Tender For expression of interest invited for association as sub contractor through pre bid tie up from exp. agencies for constr. of new bg line incl. electrical, signal, telecommunication works b/w jumlapur road (excl)... and gurgunta(incl)... under gadag wadi... on epc mode
Tender For tender for appointment of contractor to carry out electrical and air conditioning work at new alternate premises of jalgaon branch from empaneled contractors of nasik region only
Tender For supply of demand of maintenance stores c c--- led batten (q2) , led luminaire for road and street lights (v2) conforming to is 10322 (part 5 / section 3) (q3) , led luminaire for floodlight (v2) conforming to is 10322 (part 5/section 5) (q3) , xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1) (q2) , pvc copper cable single core and multi core circular sheathed cord with flexible conductor (v2) as per is 694 (q2) , mcb - miniature circuit - breakers for a.c. operation as per is / iec 60898 (part 1) (q2) , molded case circuit breakers (mccb) as per is / iec 60947 (q3) , piano type modular domestic fan regulator as per is 11037 (q3) , piano type non modular domestic fan regulator as per is 11037 (q3) , modular piano type domestic electrical switches as per is 3854 (q3) , piano type non modular electrical switch socket combination as per is 3854 and is 1293 (q3) , elecric bells and accessories as per is 2268 (q3) , astronomical time switch based on lux level , bell push piano type switch 6amp , aluminium cable lugs 120 sqmm , aluminium cable lugs 150 sqmm , aluminium cable lugs 185 sqmm , aluminium cable lugs 25 sqmm , aluminium cable lugs 35 sqmm , aluminium cable lugs 50 sqmm , aluminium cable lugs 70 sqmm , aluminium cable lugs 95 sqmm , aluminium service cable 10 sqmm 2 core , aluminium service cable 4 sqmm 2 core , aluminium service cable 6 sqmm 2 core , capacitor 2.5 mfd , led bulb 5w , led bulb 9w , led panel light 18w , plug top 16amp 3 pin , plug top 6amp 3 pin , pvc tape adhesive 20mm x 25mtr , pvc tape adhesive 25mm , pvc tape adhesive 35mm , piano type 1 way switch 16amp , piano type 1 way switch 6amp , piano type 2 way switch 6amp , socket 15amp , switch socket combination 5amp 5 pin , led bulb 7w , led thread type 9w , power contractor 16amp 4 pole , led street light driver 45w , led street light driver 120w , led street light driver 70w , led street light driver 60w , onload change over switch 40amp 4 pole , onload change over switch 63amp 4 pol
Tender For engagement of contractor for taking over the job of operation and maintenance of electrical and instrumentation systems in 1mtpa plant at ariyalur cement works, ariyalur district
Tender For tender for supply of deisgn engineering and supply of electrical instrumentation and civil works : : - design and engineering of imcc panel 2 nos and vfds , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cable laying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , supply of imcc panels , vfd panels , supply of apfc panels , hvac system , supply of mldb lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material etc , supply of field instruments and necessary piping materials as required , supply of plc , supply lt cables and other related accessories for electrical , termination material and other instrumentation cables as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables ( cable terminations wherever required along with necessary accessories is in the scope of the contractor) for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , substructure excavation , foundation works (footings , columns up to plinth level) , dpc (damp proof course) , and backfilling. , superstructure columns , beams , slabs , brickwork/masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring (tiles , marble) , painting , wall cladding , and other interior/exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cable laying for both incoming and outgoing cables