Web Analytics Made Easy - StatCounter

Electro Mechanical Spares Repair Tenders

Get complete information related to latest Electro Mechanical Spares Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electro Mechanical Spares Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electro Mechanical Spares Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Corporations/Associations/Others

CTN :45532318 Due date: 09 Jul, 202609 Jul, 2026 19.50 Lacs
Tender For corrigendum : repair and maintenance work of foot path and light arrangements,eb board,play materials and name board works in tnhb p-iii park at ward no.33 zone -4 in tcmc - eangaging of man power for cleaning weeds and bushes at lawn areas cutting plants and grass including all labour charges etc complete, gardener 5 days 6 nos, mazdoor ist class, engaging of ac electric grass cutter on hire basis including hire charges transport charges and all labour charges etc complete, supply and fixing of childerns play materials including cost and conveyance and fixing and proper alingenement charges etc complete, slider, 2 seater swing, 4 seater see saw, supplying and filling in foundation and basement with river sand in play area in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification., supply and fixing of light pole 4 metre length single bracket pole with base plate (250 x 250 x 6mm)76.10mm od x 3.65mm thick x 4000mm length etc.,completed, supply and fixing of 30w led street light fitting with led on out door fittings including cost and conveyance and fixing charges etc complete, supply and fixing of synthetic moulded compound box for street light with 16 a mcb and connecterincluding cost and conveyance and fixing charges etc complete box-735+16 a mcb sp and neutral -382, supply and fixing of 4 sqmm pvc unsheathed copper cable including cost and conveyance and fixing charges etc complete , supply and laying of 2 x 10 sq.mm pvc armoured ltug cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good sd 194, centering and shuttering charges for all pcc and rcc works using ms steel moulds and soffits strutting with casurina props 10-13 cm dia including cost and conveyance of all materials and including all labour charges etc complete, plain cement concrete 1;2;4 mix using 20 mm hbg iss metal including cost and conveyance of all materials and including all labour charges etc complete, supply and filling of on quarry rubbish 15 cm thick on each layer including cost and conveyance and all labour charges for filling and consolidation charges etc complete, cement concrete 1:5:10 (one cement, five crushed stone sand and ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard speci cation and as directed by the departmental of cers. -mixing by manual means, paving the oor with pre-polished concrete anti-skid tiles (required shape and design) of 20mm thick of approved quality and colour laid in accordance with is 1443 over a cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required cement slurry and mortar plasticizer and pointed with white cement mixed with colouring pigment at the rate of 0.40 kg. / sq.m., curing, etc., complete complying with standard speci cation and as directed by the departmental of cers. (the make and brand of the tiles should be got approved by executive engineer before use on works), supply and fixing of m.s grills with doors and windows with one coat of red oxide with primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification., supply and fixing of stone bench including cost and conveyance and fixing and proper alingenement charges etc complete, supply and delivery of ms kiosk of size 0.75m x 0.45m x 0.75m made up of ms angle of size 50mm x 50mmx 4mm alround covered with 16 gauge ms sheet and kiosk door made up of ms plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements and labour charges etc.,(twad sor 2025-26 unicode wd-m1471 clau

Central Government/Public Sector

CTN :45707591 Due date: 15 Jul, 202615 Jul, 2026 30.00 Lacs
Tender For repairing replacement of internal wiring fitting and fixture and various type of led fitting and connected earthing items at domestic area at af stn naliya - materila and labour for point wiring with 1.5 sq mm frlsh single core pvc insulated unsheathed 1100 v grade with multistranded copper conductor drawn through pvc casing and capping with all accessories fixed to wall froofs ceiling etc and incl provision of 1.5 sq mm pvc insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly including pvc box isi marked of suitable size for mounting the switches, socket outlets, fan regulators etc., complete all as specified and directed for following:- one light/fan point controlled by one switch. one socket 3 pin outlet 5 amp on independent board. one light point controlled by two 2-way switches. one 3 pin socket outlet 5 amp on the same board with other switches. one bell/buzzer point controlled by one push button on the same board with other switches or independent with cable 1.5 sq mm size. all as per serial item number 2.00 here-in-before but with copper conductor cable of 2.5 sqmm size for one 3 pin socket outlet 15 amp independent board with cable 2.5 sq mm copper cable as earth continuity conductor. supply and fix in replacment of switch piano flush type single pole one way 5 amp, complete all as specified and directed. supply only socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed. supply only socket outlet multipurpose 213 pin 5 amps flush button type with universal box in polycarbonate complete all as specified and directed. supply only switch socket multipurpose 2 in 1,5 and 15 amps complete all as specified and directed. supply only ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed. supply only switch bell push, flush type 5 amp. supply only electric bell ding-dong ac 230 volt sp with brass screws and cup washers all as specified and directed. pa supply only hylem sheet 3 mm thick size 9" x 11" including cutting of switch,socket complete all as specified supply only hylem sheet 3 mm thick size 8" x 5" including cutting of switch,socket complete all as specified supply only mcb single pole and neutral 32-63 amps, 240 volts, complete all as specified and directed. all as per item ser no 60 above but with two run of single core 6 sq mm and one run of 6 sq mm frlsh as earth wire s&f in replacement of 9 watt led bolard lights 4300/6500 k in rectangular shaped victorian design with opal acrylic diffuser and ip 65 protection,including pcc work for mounting the fittings with suitable size of nut, bolts and connection with two core copper cable all as specified and as directed. make bajaj, havells, crompton. m&l for repair / maint of wooden/steel boards for electrical db of any type and size including replacement of doors as per site requirement, hinges, handle and locking arrangement with necessary welding works, wooden works to make good the wooden / steel boards including painting with synthetic enamel paint of one coat all etc complete. the quoted shall be inclusive of replacement of wooden doors! steel doors/hinges! locking system/welding work required for repair/fixing of new doors etc complete pac s&f in replacement of 36w led recessed 2x2 luminaire 6500k fixed in the existing ceiling/roofs white powder coated crca housing with led seanless front frame with flat white transmission acrylic cover and necessary connection with twin core copper cable of suitable size in kutch auditorium with ceiling height of more than 20 feet including necessary arrangement for scaffolding ladder for replacement of ceiling lights all as specified and as directed. note: the quoted rates are inclusive of necessary safety arrangements iscaffolding/ladder etc complete all as specified and directed

Central Government/Public Sector

CTN :45450690 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For corrigendum : repair repl of intl elct wks incl rewdg of clg fan exh fan w/m fan lt ftgs sub main wirg geyser and oth allied wks incl ot lts at ph i of mh kke repair maint of diesel generator set amf pnls synch pnl and allied wks at mh kke range hls area hq 41 arty div and aund - repair replacement of internal electric works including rewinding of ceiling fan, exhaust fan, wall mounted fan, light fittings, sub main wiring, geyser and other allied works including ot lights at phase-1 of mh khadki including 41 arty div and repair and maintenance of dg set, amf panels, synchronising panel and allied works at mh khadki, range hills area, hq 41 arty div and aundh military complex under ge (mh & rh) khadki

Central Government/Public Sector

CTN :45475154 Due date: 07 Jul, 202607 Jul, 2026 30.00 Lacs
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get

Central Government/Public Sector

CTN :45726549 Due date: 20 Jul, 202620 Jul, 2026 NA
Tender For repairs maintenance of electrical and mechanical equipments high mast light search lights and other miscellaneous items at cad pulgaon - disconnecting and taking down existing unserviceable street lights/flood lights any type/watts from pole/wall and dismantling the light fittings. repairing/replacing unserviceable parts re-fixing the same on pole/wall after testing and removal of carbon from line jumpers/tightening of jumper/alignment of fitting defective street light/security light/flood lights fitting/led light from electric pole complete all as directed by eic. note: spare parts and accessories such as led driver, and connected items etc will be measured and paid separately under respective item as supply only and fixing is deemed to be included in this item., supply only led street light driver for 45 watts led street light as per make given all as specified and directed by eic., supply only led street light driver for 60 watts led street light/ flood light type as per make given all as specified and directed by eic., supply only led street light driver for 100 watts led street light/ flood light type as per make given all as specified and directed by eic., supply and fix in repair led streetlight of 45 watt comprises of pressure die cast aluminium housing & having system efficiency>123 lumens/watt i.e 5570 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k,pf>0.9,driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account. 3.the complete fitting along with led module, driver, surge protection device and all associated accessories shall be covered under 05 (five) years comprehensive warranty by the contractor from the date of invoice.make : philips/ wipro/crompton, supply and fix in repair led streetlight of 60 watt comprises of pressure die cast aluminium housing & having system efficiency>110 lumens/watt i.e 6670 lumens,all leds should be highpower leds of 1w to 3w only with modular lens for batwing shape distribution of 30 degree & 60 degree,input voltage working range is 140 vac to 270 vac,brand name should be embossed,potted driver is used with 4kv internal & external 5kv potted surge protection,short circuit protection,open circuit protection,high & low voltage protection,fixture should withstand high & low voltage protection,fixture should withstand high voltage upto440 v for 8 hr,ip66 protected,thd10%,cri>70 cct 5700+/-300k, pf>0.9, driver efficiency>85%,lm79 report required from nabl accredited lab. including taking down old unserviceable fittings and bracket house must be adjustable or if required any cost of all fixing hardware shall be included in quoted rate complete all as specified and directed by eic. note : 1. engraving of ca number on each lighting fitting (street light / flood light) shall be carried out by the contractor and the cost of the same shall be deemed to be included in the quoted rate. 2. no extra payment shall be made on this account.3. the complete fitting along with led module, driver, surge protection device and all as

Central Government/Public Sector

CTN :45719626 Due date: 18 Jul, 202618 Jul, 2026 40.00 Lacs
Tender For repair/ replacement of lt cable, lt panel and connected items in domestic area (excluding camp area), su site 1a and 1b at af stn jodhpur - excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed., returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.complete all as specified and directed., removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in any type of soils.complete all as specified and directed., m&l for sand cushioning for xlpe cable with tibba sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punning down to 180mm to provide a required cover complete all as specified and directed by the engineer-in-charge.note:- punned thickness only shall be measured and paid., m&l for protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class b bricks complete all as specified and directed by engr-in-charge., supplying and laying un-reinforced precast concrete cable cover, class lv, type i, flat, size 250mm x 150mm x 40mm confirming to is - 5820 complete all as specified and as directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable, laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm, 3.5 core complete all as specified and directed., taking down of lt cable any size from trech/ gi pipe/ walls/ on ground/ street light poles complete all as specified and directed., m&l for boring of holes under road, pavement, hard stansding by using manual method with 100mm hdpe pipe complete all as specified and directed by engineer-in-charge., s&f in repair mccb 400 amp, 4 pole, 415 v, 36 ka, thermal megnatic adjustable type complete all as specified and directed., s&f in repair mccb 250 amp, 4 pole, 415 v, 35 ka, thermal megnatic adjustab

corporations/Associations/Others

CTN :45702242 Due date: 07 Jul, 202607 Jul, 2026 17.03 Lacs
Tender For regular operation and maintenance of street lights (with material) at all industrial areas under riico ranpur kota(for 2 years) - regular operation and maintenance of high mast light in ranpur , kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register shall be maintained at riico/association office and complaint lodged must be attended by contractor within 24 hours. the person deputed by contractor shall attend the riico/association office daily and comply the instructions and attend complaints regularly. iii contractor will have to employ trained and qualified electricians for the work. iv corporation shall not be responsible for any kind of accident during execution of work. v contractor will be responsible for safety and security of fixtures and all concerned materials. vi contractor will be responsible for arrangement of all t&p required for the work vii cost of all labour and material like lamp / balllast wire etc. will be born by contractor. all material required for the work shall not be below the category-ii of concerned bsr item. contractor has to repair and maintenance of fixture with material in all cases like short circuit, phase to phase of jvvnl line etc. viii no extra payment will be made for fixing/removal of extra/existing fixture in the industrial area. ix contractor will be responsible for timely collection and deposition of electric bills of areas in each month. in case of delay in payment and jvvnl impose surcharge for delay payment the same will be recovered from the running bill fo the contractor. payment of electricity bill will be made by riico. x contractor will be responsible for rebate of timer provided by jvvnl. hence contractor will maintain the on/off system by timer properly. in case no rebate is provided by jvvnl due to failure of timer then rebate will be deducted from contractor payment. xi contractor will be responsible for any theft of electricity through poles and he will make necessary arrangements for this. in case of any theft is found suitable penalty will be imposed on the contractor. xii contractor will maintain cubical panel board and assessories fitted in it. in case of any fault repair/replace of material will be done by the contractor at his own cost. no extra payment will be made on behalf of material. xiii contractor has to keep ready total fixtures. in case of fault of fixture a penalty of rs.100/- per fixture per day will be imposed on the contractor., regular operation and maintenance of street light fixtures hpsv/ hpmv (70w/150w) in ranpur, kota including supply and replacing the required material and labour etc. complete as per the following terms and conditions:- i at any moment a minimum of 90% of total fixture must be in order. the defective fixture must be repaired within 3 days, falling which deduction for number of light which are not functioning in the industrial area shall be made at one time of the rate (accordingly deduction for lights which are not functioning becomes two times of the rates from total payment due for total number of lights whose operation and maintenance was awarded to the contractor ). ii contractor shall arrange at his cost for put on & off the street light fixture at appropriate time regularly as per instructions of engineer-in charge. a register sh

CTN :45741643 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For supply of brg clutch release 2326570 coo , weather strip , drive assy , arm wind screen wiper s a of wiper , repair kit pumping assy , horn assy high tone , cap actuator , electric fan assy , bearing frt wheel , reverse light , air filter element safety , oil filter assy , starter motor assy , nozzle , pump water , flat seal ring , camplate , valve brake pneumatic , repair kit , adjusting pin , roller , gasket cylinder head , motor assy wiper , battery cut off switch , repair kit minor slave cylinder , cable assy control , cable assy clutch control complete , oil seal , wire harness , glass bedding

CTN :45558487 Due date: 03 Jul, 202603 Jul, 2026 20.00 Lacs
Tender For corrigendum : invitation for annual rate tender for the procurement of electrical and lighting materials - electric choke 40 watts bulb 200 watt bulb holder aluminum wire 2.5 mm isi mark (havels/anchor). copper wire 2.5 mm heavy mark (havels/anchor) aluminum wire 3 mm heavy mark (havels/anchor). copper wire 3 mm thick mark (havels/anchor) copper wire 0.75 mm thick mark (havels/anchor). aluminum wire 6 mm heavy mark (havels/anchor). auto switch small unit auto switch buddy unit complete fracture led 24 watt (havells/philips/bajaj/kww/wipro) isi mark complete fracture led 36 watt isi mark (havells/philips/bajaj kww/wipro) auto day - night (separate-2) led light repair 30 watt led light repair 45 watt led bulb 5 watt (havells/philips/bajaj kww/wipro) led 8 watt (havells/philips/bajaj kww/wipro) led plate 26 watt led plate 45 watt led driver (choke) 24 watts led driver (choke) 25 watt led driver (choke) 36 watts led driver (choke) 45 watts led glass 24 watt led glass 25 watt led glass 36 watt led glass 45 watt ceiling fan bajaj cooler of iron (summercool) paste led cooled led 45 watt (havells/philips/bajaj/kww/wipro) raga plas (taparia) screwdriver (taparia) cutter (taparia) tools (taparia) sensor autocut main switch kilo watt sensor autocut main switch single main switch 63 to 200 ampere led light 25 watt automatic on off (isi marks) led light 45 watt automatic on off (isi marks) timer switch vaux 1 kw (isi marks) timer switch vaux 2 kw (isi marks) timer switch vaux 3 kw (isi marks)

CTN :45715337 Due date: 06 Jul, 202606 Jul, 2026 4.70 Lacs
Tender For 1. repair maintenance of of electrical installation fans electric sub station water supply pump street light split hot and cold inverter based ac cctv lift at r and t wing production wing and repair maintenance of of 2x750 kva sub stain at dpt 2. repair maintenance of ac plants for animal house and central drugs laboratory at cri kasauli hp sh servicing of ht /lt sub staion equipments dehydration of transformer oil etc.
 Loading, Please wait...

Connect us via What's Up