Tender For supply of wattmeter portable dynamometer , module as per equipment list on2 , throttling calorimeter-2 , cut section model 4 stroke single cylinder petrol engine and desel engine-1 each , gravimetric analysis-1 , module as per equipment list on 6 , exhaust analyser for petrol and diesel engine , single stage reciprocating air compressor , rotary compressor, air compressor , flash point apparatus , pyrometer, infrared, thermocouple , lancashire boiler model, nestler boiler model 1 each , model of impulse turbine , model of reaction turbine , model of surface condenser , bab cox and wilcox boiler model , heat transfer for conduction convection radiation 1 set , steam separating and throttling calorimeter , bench bias nine inches , circular saw grainder, blade size , wood turning lathe machine-1000 mm length-1 with 2 hp motor , bench drilling machine -1 with 2 hp motor , long dand shikanja-4 feet , c clamp- 12 inches 300 mm , wood planer- 400 mm length
Tender For purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp frequency: 0.00001 t
Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgas cylinders & fittings, gas sampling: zero air, h2, n2 and helium gas cylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode
Tender For bid to ras corrigendum : supply of civil lab equipment d d - impact testing machine , crushing value testing machine , los angeles abrasion testing machine , flakiness index test gauges , elongation index test gauges , aggregate water absorption test set up , pycnometer as per requirement , is sieves for coarse aggregate gi sieves dia 300 mm , is sieves for fine aggregate brass sieves dia 200 mm , automatic sieve shaker 18 inch , bitumen extractor machine , vicat apparatus with deskpot , le-chatlier flasks , le-chatlier moulds , burette as per requirement , measuring cylinders , trowel small , trowel big , trays , sampling scoop , steel buckets as per requirement , cement cube moulds , automatic manual mortar mixer as per requirement , vibrating machine as per requirement , curing tank with controlled temperature , atterberg limits set-up liquid limit , atterberg limits set-up plastic limit , shrinkage limit apparatus with mercury , hydrometer analysis set-up range , free swell index apparatus , proctor testing equipment , core cutter test set up for in-situ density min. 6 mould with 01 hammer , sand replacement test set up for in-situ density , moisture container for omc by conventional method , hot air oven digital , physical balance electronic , rapid moisture meter , thermometer for measurement of room temperature , thermometer for measurement of temperature of bitumen, concrete , digital compression testing machine 2000 kn capacity semi automatic , digital compression testing machine 500 kn capacity , measuring tape 3m , measuring tape 10m , measuring tape 30m , measuring tape 50m , concrete cube moulds , concrete mixer 0.5 cum capacity electrically operated , concrete workability test by compaction factor test , ph meter , paint thickness meter elcometer ultrasonic digital , dial callipers , vernier callipers , digital micrometre , outside micrometres , depth gauge , density pot , density basket , slump test apparatus , electric platform balance 150 kg , electric pan balance 10 kg 1gm , precision balance 600 gm 0.1 gm , measuring flask , upv ultrasonic pulse velocity tester , rebound hammer , core falltering machine , flexural test appratus for beam , core cutting setup for conceret , rebar detector to locate reinforcement before core cutting
Tender For supply, installation, testing and commissioning of one high performance liquid chromatography (hplc) system for the drug and cosmetics analysis centre, department of chemistry, university of calicut under pm-usha scheme from original equipment manufacturers (oems) or authorised distributors/dealers.
Tender For corrigendum : providing of custom bid for services - 9070c25c63 lining up agency for root cause analysis of rotary equipment as well as piping and structures by using operating deflection shape method at paradip refinery odisha
Tender For providing of testing service for on-board /commissioned equipment/ instrument related to plant - civil; penetrant testing facility, specific gravity, moisture content, ph, atterberg limits , soil/particle grain size using sieve/hydrometer analysis, shrinkage lim..