Tender For procurement of electrical material for day to day maintenance of various municipal buildings in ward 79 under city sp zone. - supply of 6 sq. mm isi marked, frls pvc insulated, single core copper conductor cable, supply of modular base & cover plate for 4 module, supply of modular base & cover plate for 8 module, supply of modular base & cover plate for 12 module, supply of modular gi box for 4 module, supply of modular gi box for 8 module, supply of modular gi box for 12 module, supply of s.p. 5/6a, one way modular switch, isi marked, supply of s.p. 15/16a, one way modular switch, isi marked, supply of 3 pin 5/6a modular socket outlet, isi marked, supply of 6 pin 15/16a modular socket outlet, isi marked, supply of 32/0.20 mm (1.0 sqmm) twin circular, frls pvc sheathed, workshop flexible copper cable, supplying of led surface mounted batten light of following body material and construction as per is : 10322 with driver (replaceable) as per the requirement with driver efficiency >85% ,operating voltage ac 140-270 volt, freq 50/60 hz, operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 kv with short & open circuit protection ,thd 10% , p. f. 0.95, ip20, cri >80, flicker free, (flicker should be below 5 %), life time (led,driver & electrical circuitary), of minimum 50000 burning hours with , 70% of initial lumen maintained till life ends, cct 3000 k / 4000 k / 5700 k /6000 k/6500 k (as per ansi bin), sdcm (standard deviation color matching) 3, maximum power consumption should not more than the specified rating and fixture shall be of relevant bis standard and trade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing. complete in all respect i/c connections with 1.5 sq mm frls, pvc insulated copper conductor single core cable and earthing etc. as required with minimum 5 year oem warranty. system lumen efficacy 105 120 lm/watt output . lm79 & lm80 test report from nabl lab for all testing required for led fixtures as per bis shall be submitted. shape size and cct shall be as approved by engineer-in-charge as per requirement. (thermal management: heat sink of aluminum housing such that led junction temperature shall not rise above 90 c).powder coated die cast/extruded aluminium body (thickness>1.20mm) 18-22 w, supply of ceiling fan with brush less direct current (bldc) motor, class of insulation: b, 3 nos. metal (aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/al body power factor not less than 0.9, service value (cm/m/w) minimum as below, 350 rpm (tolerance as per is : 374-2019), thd (total harmonic distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega ohm, suitable for 230 v, 50 hz, single phase ac ceiling fan compliant to is 374:2019 fan supply, earthing etc. complete as req 1400mm, service value 6.0 cm/min/watt, air delivery 245 cm/min (minimum), supply of 6-32a ratings, sp mcb "c" curve, 10ka breaking capacity, supply of 40a, 2 pole isolator, supply of 25a rating , 2 pole rccb, 30ma., supply of stepped type modular fan regulator (2 module), supply of pvc insulated tape roll 18mm wide of 8 metre length isi marked complete as reqd., supply of xlpe insulated pvc sheathed al. conductor un-armoured cable 1.1kv grade conforming to is-7098 of following size:- 2x6 sqmm
Tender For procurement of spares for mi-17 helicopter - relay, pipe, pipe, rod control, clamp, clamp, strip, clamp, block assy, temperature actuator, bolt, switch, bearing, electric motor, over voltage relay, relay, contactor, integrated circuit, module, relay, contactor, commutator, branch, coil, plate instruction, pipe, receiver unit ppu- p1, type iii cap, panel, relay res60
Tender For supply of alarm monitoring system ams with software as per tts , control panel with 15 inch ams display and yard supplied equipment in switchboard room bulk head mounted as per tts , display of 12 or 15 inch flush mounted on bridge console display size will be confirmed during detail design as per tts , power supply to the displays is either from individual 230v ups or from common 24v dc ups as per design and tts , audio visual high intensity flashing beacon as per tts , i o cards digital analog digital counter rpm rtd serial link etc network switches etc as per design and tts , alarms printer as per tts , ups with batteries cum dc distribution board of suitable capacity refer clause 8.2 as per tts , addressable fire detection and general alarm system as per tts , combination detector smoke or heat or rate of rise temperature or uv-ir or optical with base and mountings as per tts , heat detector with base and mountings as per tts , flame detector with base and mountings as per tts , indoor manual call points with mountings as per tts , outdoor manual call points with mountings as per tts , general alarm push button with cover to avoid accidental activation with mountings as per tts , sensors or switches for monitoring door status open or close as per tts , bilge level float switches as per tts , high level float switches side mounted for fuel oil tanks as per tts , high level float switches top mounted for dirty oil tank as per tts , temperature transmitter as per tts , pressure transmitter as per tts , supporting accessories wt junction boxes cable connectors glands interface converters power supply converter with auto transfer switch galvanic isolators , special cables refer clause-11 as required as per tts , obs list of spares and qty as required as per tts , special tools and commissioning spares as required as per tts , class inspection charges as lumpsum , documentation drawings certificates installation operational and maintenance manuals as per tts , service support for training testing commissioning and trials as lumpsum , any other item not included above however the same would be required for proving the system during commissioning or hats or sats as required as per tts , man day rate for deputing service engineer beyond lump sum cost due to delay beyond control of supplier
Tender For corrigendum : tender for supply of miscellaneous items for routine maintenance : : -handheld digital multimeter , wse frp junction box , street light pole , geared crimping machine upto 400 sqmm , sensing probe electronicspeedswitch , bmh e linear actuator 400 mm , flexible cable duct tray p n 29490. , drill bit masonary 4mm , drill bit masonary 6mm , drill bit set , hss 4 , 5 , 6 , 8mm one each , tub spanner set 6 22mm , combination plier insulated , grease gun heavy duty , wire brush , stainless steel , 4 rows , industrial hole saw cutter 3 by 4 inches , pistol drill m c , hammering action 230vac , wsi portable hot air gun , zn pass.m6x50 nutbolt set , zinc.pass.m8x25 nut bolt. , wooden screws size no.8 x 35 mm , screw driver set , self adhesive aluminium tape , size 2 inches , teleguard ladder al , 15ft , 7 9 rung , wsi soldering iron , 25 w , 230 vac , solder wire 22swg , wire stripper for removi , din rail 35 x 7.5 mm , l 2 mtrs