Web Analytics Made Easy - StatCounter

Energy Meter Tenders

Get complete information related to latest Energy Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Energy Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Energy Meter Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :39864914 Due date: 08 Apr, 202508 Apr, 2025 14.94 Lacs
Tender For supply of universal standard energy meter and its operational training to etl ramnagar/nainital

State Government

CTN :39864922 Due date: 08 Apr, 202508 Apr, 2025 14.94 Lacs
Tender For supply of universal standard energy meter and its operational training to etl haldwani

Central Government/Public Sector

CTN :39875871 Due date: 21 Apr, 202521 Apr, 2025 1.97 Lacs
Tender For supply of ac static watthour meters - energy meter (v2) as per is 13779 (q2)

Central Government And Public Sector

CTN :39861587 Due date: 08 Apr, 202508 Apr, 2025 2.95 Lacs
Tender For replacement of damaged lt meter panel boards at bts sites under eluru ba - electrical items :, supplying and laying of out door type 3 chamber ms box (min size:32inch(w) x 30 inch(h) x 12 inch (d) for housing 1ph/3ph energy meter direct type -1n0, 100a fuse cutout -3nos, 63a on load change over swich - 1no with suitablems enclosure on surface of wall/ms angle iron frame,painting completeas required (note:all 3chambers shall be invidually separated, shall have individual doors with locking arrangement, meter chamber shall have opening with glass provision for meter reading from out side . all chambers shall have suitable holes for cable entry. panel shall be powder coated & din rail shall be provided inside panel chamber wherever necessary for fixing mcbs complete etc. as required., supplying and laying of out door type2 chamber ms box (min size:30 inch(w) x 20 inch(h) x 12 inch (d) for housing 1ph/3ph energy meter direct type -1n0, 100a fuse cutout -3nos, - 1no with suitable ms enclosure on surface of wall/ms angle iron frame,painting completeas required (note:all 2chambers shall be invidually separated, shall have individual doors with locking arrangement, meter chamber shall have opening with glass provision for meter reading from out side . all chambers shall have suitable holes for cable entry. panel shall be powder coated & din rail shall be provided inside panel chamber wherever necessary for fixing mcbs complete etc. as required., supplying and fixing of the 3 nos 100a porcelain fuse cutouts along with 100a neutral link on suitable board in existing panel etc. as required. ( m/s anchor/bosma or equivalent make ), supplying and fixing of the 1 no 100a porcelain fuse cutouts along with 100a neutral link on suitable board in existing paneletc. as required. ( m/s anchor/bosma or equivalent make ), supply and fixing of 4 pole 63a onload changeover switch suitable for 415v, 3phase power supply in the existing suply to ea set as required.( make hpl or ss make), supplying and fixing of 240v,10ka "c" curve 63a dp mcb for inductive load in the existing panel complete with connections, testing and commissioning etc as required., supplying and fixing of 415v,10ka "c" curve 63a tpn mcb for inductive load in the existing panel complete with connections, testing and commissioning etc as required., supplying and laying of pvc insulated 25 sqmm aluminium conductor single core power cableof 1.1 kv grade complete as required., supplying and laying of 8swg gi support wire complete as required, supplying and fixing of the 50mm pipe pipe for service pole etc as required., supplying and fixing of the 40mm pvc pipe on surface wall for service etc as required., s/f of the size of 40mm x 40mm x 5mm thick ms angle including cutting, bending, grouting in wall, painting etc as reqd, fixing charges for the apcpdcl 3ph/1ph energy meter in existing meter box by co-ordination with spdcl staff,testing complete as required.

CTN :39859416 Due date: 09 Apr, 202509 Apr, 2025 NA
Tender For supply of ac static watthour meters - energy meter (v2) as per is 13779 (q2)

CTN :39874922 Due date: 11 Apr, 202511 Apr, 2025 NA
Tender For supply, fixing and commissioning of 3ph (three phase) ct operated energy meter with keyp ad., accuracy class 1.0, 240v, 10-100a, 50 hz, in-home display unit with box similar to lnt model no. 4000 senes-wd4000103ooo. make : secure, hpl, l&t or similar. [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :39850735 Due date: 09 Apr, 202509 Apr, 2025 NA
Tender For ac whole current 3 phase 4wires smart energy meter with bidirectional communication facility suitable for advanced metering infrastructure (ami) with connect/disconnect switch. the meter shall communicate with head end system (hes) on cellular communication technologies mentioned in is16444part1, as per the requirement of the utility/authorized system integrator.

Central Government/Public Sector

CTN :39874761 Due date: 07 Apr, 202507 Apr, 2025 NA
Tender For supply of ac static three phase energy meter with outdoor enclouser, current rating-(10 to 6 0) amps. (version 2.0) conforming to is-13779 make techno, hpl, secure or better. [ warranty perio d: 30 months after the date of delivery ]

Private Sector

CTN :39839162 Due date: 01 Apr, 202501 Apr, 2025 NA
Tender For purchase of ht & single-phase energy meters for releasing service connection to prospective consumers in shendra & bidkin industrial area.

Central Government And Public Sector

CTN :39860496 Due date: 02 Apr, 202502 Apr, 2025 NA
Tender For supply, installation & commissioning of ac three phase ht ctpt multifunction dlms complia nt energy meter of accuracy class 0.5s, 3 x 63.5v, 50hz with optical & rs232 or rs485 port, backlit lcd di splay, (measures kwh, kvarh lag & lead, kvah ,md kw & kva , instantaneous parameters like v,i,pf,frequ ency, etc., 6 months history of energy & md, load survey, tod, tamper detection & logging, power on/off events of rating -/5a or -/1a with display in absence of power. default pt ratio*: 11kv/110v & ctr: 1 [ war ranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up