Tender For construction of 04 no. 33 kv, 5.43 mvar capacitor bank 01 no. at 132 kv gss ajasar (jaisalmer), 01 no. at 132 kv gss mohangarh (jaisalmer), 01 no. at 132 kv gss sangarh (jaisalmer) and 01 no. at 132 kv gss jhinjhinyali (jaisalmer)
Tender For corrigendum : enquiry for hiring of vehicle type e air-conditioned jeep category muv with min engine capacity 1450 cc for petrol diesel with airbags and abs capacitor bank to be utilized by dgm stc-stm vehicle will be running datia oo d.g.m stm mpmkvvcl datia
Tender For replacement of various 132 kv line control panel and 63 mva tf c and r panel and 33kv triple feeder panel and 33 kv capacitor bank panel at 132 kv sub station boner under etd-i, aligarh
Tender For replacement of age old 66kv pneumatic circuit breaker and c&r panel of 66kv capacitor bank at 220kv r/s hoody. pertaining to tr (op) circle-south, bengaluru on total turnkey basis including supply of all matching materials/equipment including supply of 66kv breakers and erection (including civil works) of all materials/ equipment, testing and commissioning- on percentage basis
Tender For augmentation of 1x12.5mva by 1x20mva power transformer related works along with provision of 11kv switchgear, capacitor bank at 66/11kv akkurmole sub-station in channapatna taluk, ramanagara district on partial turnkey basis including supply of all matching materials (excluding supply of 20mva power transformer, nifps system & 11kv switchgear) /equipments and erection (including civil works) of all materials/ equipments, testing and commissioning
Tender For corrigendum : supply of spares for 02 nos float and boost chargers for 220 vdc and 48vdc battery bank at power house c c - 16a ammeter selector switch for main input current selection , 16a voltmeter selector switch for main input voltage selection , 10a tp ac 2 way without off auto or manual mode selection for float and boost chargers , 16a sp dc 2 way without off switch for float rectifier or load bus and boost rectifier or battery voltage selector switch , 16a sp ac 2 way without off auto c or o mode or manual boost mode selection for charger , 10a tp dc 2 way without off for boost charging of battery set 1 or 2 selection , 225a dc coil operated emergency contactor coil 220v dc auxi 1no , 185a dc coil operated contactor for boost charging battery set 1 coil 220v dc auxi 2 nc , 63a dp dc on or off switch for load isolation , 40a dc coil operated emergency contactor coil 48v dc auxi 1no , 65a dc coil operated contactor for boost charging battery set 1 coil 48v dc auxi 1 nc , filter capacitor for ripple suppression for float and boost chargers rating 100 v 2200 uf , dc to dc convertor 48v dc to 24 v dc 5 amps , 4 channel relay boards for contact multiplication of card mounted protection relays , electronic card module for avr and current limit for float charger auto and manual mode , electronic card module for avr and current limit for boost charger auto and manual mode , electronic card module for float and boost rectifier fuse fail and filter fuse fail , protection module for various fault detection and annunciation , blocking diode for float and boost charger rating 70a i avg piv 800 for fcb mode on k3 heat sink , 80 percent blocking diode stud type rating 70a i avg piv 800 on k3 heat sink , latching resistor for rectifier. 250 ohms 50 watts for float and boost chargers , 10k 1w potentiometer for auto or manual voltage adjust in float charger , 10k 1w potentiometer for auto or manual current adjust in boost charger , 2ph control transformer for power supply of avr cards prim 415 v sec 16 0 16 v ac 400ma , 3ph control transformer for synchronising of avr cards. pri 415 v sec 16 0 16 50ma , 3ph control transformer for ac u or v pri 415 v 3 phase sec 0 16 vac 1 phase 250 ma , 2 0fi control transformer for fan control supply prim 415 v 2 phase sec 190v ac 50va , scr stud type 70a with heatsink loose module only , diode free wheeling stud type 70a with heatsink loose module only , digital ac ammeter 48 x 96 sq mm class 1 ct ratio 25 or 1a auxiliary voltage 24v dc , digital ac voltmeter 48 x 96 sq. mm class 1 range 0 500v ac auxiliary voltage 24v dc , digital dc ammeter for float boost chargers and 80percentage cell tap 48 x 96 sq mm class 1 75mv dc with shunt auxiliary voltage 24v dc , digital dc voltmeter 48 x 96 sqmm class 1 range 75mv dc auxiliary voltage 24v dc , digital dc charge or discharge ammeter for battery 48 x 96 sq mm class 1 range 75mv with shunt auxi 24v dc , transportation charges for material
Tender For corrigendum : capacitor bank 1.98 mvar - 1.98 mvar 11 kv design for 12.65 kv outdoor type, in crca cubicle shunt capacitor bank with vcb, isolator, current transformer, lighting arrestor, rvt, series reactor & automatic power factor controller