Tender For providing of selection of laboratories for testing of products/material - drinking water; buyer to use custom filter to input technical specification of the product/material so that service provider may provide price offering accordingly; sample; chemical
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou
Tender For supply, scope of work and technical specifications for the implementation of automatic generation control (agc) in mtps unit 1 to 6 (4x210 mw + 2x250 mw), ctps unit7&8 (2x250 mw) and rtps unit 1&2 (2x600 mw), dvc to be operated from nldc/sldc for providing secondary reserve ancillary service (sras)
Tender For corrigendum : supply of lan system as per scope of supply in sotr yard 1280 , technical documentation , training , installation and commissioning spares , service engineer charges , lan system as per scope of supply in sotr yard 1281 , lan system as per scope of supply in sotr yard 1282 , lan system as per scope of supply in sotr yard 1283 , lan system as per scope of supply in sotr yard 1284 , lan system as per scope of supply in sotr yard 1285 , lan system as per scope of supply in sotr yard 1286
Tender For corrigendum : construction of rcc framed fly ash brick masonry compound wall with concertina coil 3 no gates & corresponding security rooms for sammakka sarakka central tribal university (ssctu) mulugu telangana.sh: providing day to day service like technical assistant on monthly contract basis located at sammakka sarakka central tribal university (ssctu) mulugu telangana for the o/o the assistant engineer (civil) sub division-i, cpwd, warangal.
Tender For a/r & m/o technical area building at afs hindan ghaziabad during 2025-26. (sh: providing service facilities & labour for day to day maintenance).
Tender For providing of selection of laboratories for testing of products/material - all civil tests; buyer to use custom filter to input technical specification of the product/material so that service provider may provide price offering accordingly; sample; civil