Tender For supply of chemical earthing for equipment c c - earth electrode , backfill material , copper strip , copper cable , earth inspection chamber , installation work
Tender For auction sale of depot ferrous scrap - 12226gi26k, 98011900, quantity- 20.490 mts. scrap condemned unserviceable gi material, consisting of gi sheets anti creep wire, side arm of atd, large register arm hook, c and w eye rod, double suspension clamp,9 tonne adjuster, gi channel sleeper, arm hook snap pin head, d.p. isolation base channel, l.v.c.b. pole caps, gi sheets, d.p. mechanism, traction mast pole cut pieces, dma cut mast, earthing electrode,9 tonne insulator, pedestal insulator, angles, cantilever assly channels, joists, bfb cut mast, bolts, u bolts, nuts, insulator caps, clamps, tripod antenna, la ring, anti fallen rods, atd l-angle, stay adjuster, bottom attachments, adopters, top attachments, u bolts, stay adjusters, stay sleeves, portal, drop bracket, rt tubes, bkt tubes, drop clips, isolator base, c clamps, steady arms, support angles, mast guy rod fitting, drop brackets, compensating plates, v bolts, bottom plates, super mast, bolts , compensating angles, optical fiber cable cut mast, insulators, gi u bonds, screw rods, pipes, stands, towers, buckets, pots, doper clip, snap paid pin, couplings, insulator bluff rod caps, covers and other ohe equipment of sorts and sizes, broken or unbroken, with or without insulation and with or without attachments of ms. location: bin no: 226, right side of road no- 2. hsn code- 72044900. gst- 18 percent. note: private crane permitted for loading purpose. note: - delivery on actual weighment basis only. special note: overload of the carrying capacity of the vehicle will not be permitted at the time of taking delivery, as per motor vehicle act 1988.
Tender For supply of repairs of 3 phase 25 and 63 kvatransformers under nagaland ba b b =-transportation of distribution transformer up to 3 phase 63 kva to a following specified distance 0 to 60 km , transportation of distribution transformer up to 3 phase 63 kva to a following specified distance 61 to 180 km , transportation of transformer up to 3 phase 63 kva to a following specified distance 181 to 350 km , arrangement of repaired and refurbished 3 ph upto 63 kva similar to the faulty 0 to 25 kva 11kv 440v transformer , arrangement of repaired and refurbished 3 ph transformer upto 63 kva similar to the faulty 26kva-63 kva 11kv 440v transformer , supplying and erection of three piece nonlinear resistor type lightning arrestor , supplying and erection of 11 kv pin insulator complete with large steel head g i pin nuts washers etc as required , supplying and erection 11 kv disc insulator for 11 kv over head lines with galvanised insulator fittings , 11 kv triple pole 200 a rating a b switch suitable for vertical mounting with three 11 kv polymeric insulator on 75 by 40 mm m s channels , transformer oil hv grade with suitable di electric strength and should comply with the requirements of type ii insulating oil as per is 335 2018 , supplying and laying of 2 core 16 sqmm wptc pvc insulated and pvc sheathed aluminium cable including providing 8 swg gi wire , providing earthing with g i earth plate of 600 mm 600 mm 6 mm thick including accessories and providing masonry enclosure , providing and fixing 25 mm 5 mm g i strip in 40 mm dia g i pipe from earth electrode including connection with g i nut bolt spring washer , providing and fixing 25 mm 5 mm g i strip on surface or in recess for connections etc as required , supplying and laying of 40 mm dia pvc pipe for la strip etc as required ) /bid number: gem/2026/b/7203568 * /dated: 06-02-2026 & & / bid document1 / 17
Tender For corrigendum : supply of 132 kv cable and accessories c c - supply high voltage power cable 132kv 1cx800sqmm copper conductor xlpe cable , supply hv power cable bonding cable , supply earth continuity conductor cable along with accessories suitable , supply high voltage power cable coaxial cable along with accessories , supply high voltage power cable 132kv outdoor cable sealing termination end kit compatible for 132kv 1cx800sqmm copper conductor xlpe cable , supply high voltage power cable straight through jointing kit compatible for 132kv 1cx800sqmm copper conductor xlpe cable , supply high voltage power cable 1 phase disconnecting link box with svl sheath voltage limiter suitable compatible for ehv cable system with necessary fittings and accessories at transformer end , supply high voltage power cable 1 phase disconnecting link box without svl sheath voltage limiter suitable compatible for ehv cable system with necessary fittings and accessories at switchyard end , supply high voltage power cable 1 x 3 phase cross bonding link box with svl sheath voltage limiter suitable compatible for ehv cable system with necessary fittings and accessories , supply high voltage power cable 1 x 3 phase cross bonding link box without svl sheath voltage limiter suitable compatible for ehv cable system with necessary fittings and accessories , supply high voltage power cable nonmagnetic single type cleats clamps for fixing of cable as per requirement , supply high voltage power cable miscellaneous items including cable route marker electrode etc required for cable system , supply high voltage power cable ) /bid number: gem/2026/b/7123551 * /dated: 22-01-2026 & & / bid document1 / 27consumables with limited shelf life suitable compatible for cable system , service item cable site survey refer boq item no b. 1 for detailed description of work , service item cable finalization of methodology design and drawing for railway track crossing boq item no b. 2 , service item cable unloading and verification boq item no. b. 3 , service item cable installation of 132kv 1cx800sqmm boq item no b. 4 , service item cable installation and crossing of 132kv 1cx800sqmm copper conductor xlpe cable boq item no. b. 5 , service item cable installation of bonding cable along with accessories boq item no b. 6 , service item cable installation of coaxial cable along with accessories boq item no b. 7 , service item cable installation of earthing continuity cable along with accessories boq item no b. 8 , service item cable site field testing and commissioning of 132kv 1cx800sqmm copper conductor xlpe cable system boq item no b. 9 , service item cable accessories termination of 132kv outdoor cable sealing termination end kit compatible for 132kv 1cx800sqmm copper conductor xlpe cable boq item no b. 10 , service item cable accessories jointing of 132kv straight through jointing kit compatible for 132kv 1cx800sqmm copper conductor xlpe cable boq item no b. 11 , service item cable accessoriesinstallation of 1nox3phase disconnecting link box boq item b. 12 , service item cable accessories installation of 1nox1ph disconnecting link box ccpu without svl boq item no b. 13 , service item cable accessories installation of 1nox3phase disconnecting link box ccpu with svl for cross bonding arrangement boq sr no b. 14 , service item training for 132kv xlpe system of 6no. engineers 4 no customer engineers plus 2 no. bhel engineers boq item no b. 15
Tender For 1st call:- tender for the work of carrying out the earthing audit (health assessment) of existing mat and earthing electrode (earth pit) at 400kv chandrapur 2 s/stn & 400kv switching s/stn under the jurisdiction of 400kv rs o&m div-ii chandrapur
Tender For supply of sitc of power transformer d d -power transformer 1000 kva 33 x 0. 4 kva , safe electrode earthing 393 hdg 76 mm dia x 3000 mm with 2 bfc electrodite , safe electrode earthing 393 cp 76 mm dia x 3000 mm with 2 x bfc electrodite , gi earthing strip hot dipped galvanized , copper flat strip 50 mm x 6 mm , frp chamber cover , pvc xlpe cable 1c x 400 sq. mm , alu. arm 1. 1 kv , brass gland double compression 45 mm , ms steel fabricated structure with nut and bolt , installation, testing and commissioning charges for 33 kv 1000 kva transformer along with allied work. , dismantling and shifting of existing 500 kva transformer 33 along with allied work. , installation, testing and commissioning etc , busbars aluminum bus bar 4p 415volts 3phase , pvc xlpe cable 3. 5c x 150 sq. mm, alu. arm 1. 1 kv , lt straight through joint heat shrinkable for 3. 5 c x 150 sqr mm lt cable , installation charges for lt straight through joint heat shrinkable for 3. 5 c x 150 sqr mm lt cable
Tender For provn of dry ration stores under ge 881 ews - sch a part-i (building work):-this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., construction of block of storage shed complete all as shown on drawings and as specified., total amount of sch a part - ii (site clearance/development work), total amount of sch a part - iii (internal electric supply work), total amount of sch a part - iv (protective work), total amount of sch a part - v (area drainage work), total amount of sch a part -vi (road, path and culvert work), total amount of sch a part -vii (external electric supply work), total amount of sch a part -viii (demolition/dismantling work), sch a part - ix (misc items of work) note : this schedule is not pre-priced by mes and the pre-priced rate indicated as "rs. 0.00" under col.5 signifies this fact only., double walled corrugated (dwc) pipe for cable protection with outer dia 50mm and inner dia 38mm including suitable size of coupler for connection of pipe complete all as specified and directed., point wiring for one light/fan point/call bell point controlled by one way switch 5 amp with 1.5 sqmm single core multi standed copper conductor frlsh insulated and unsheathed heavy duty cable in colour code including earth wire with cable of size 1.5 sqmm copper conductor frlsh insulated, drawn into and including concealed in pvc conduit of not less than 20mm dia and 1.5mm wall thickness (isi marked) terminated into annealed steel terminal boxes including modular plate and cover for mounting modular switch/ socket switches, sockets, fan regulators etc complete all as specified and directed., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on same board., all as per srl item no. 12.00 above but for one 3 pin 5 amp socket on independent board., earthing complete with galvanized steel earth plate electrode 600x600x6mm burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 15mm dia gi light grade protection pipe, 20mm dia gi medium grade watering pipe with funnel including charcoal, dust, salt, pcc m-15 type b1 in pit with angle iron (25x25x3)mm frame work with precast rcc 1:2:4 type b-1 cover reinforced with 8mm dia tmt bars @ 150mm c/c both ways and 12mm dia ms fabricated handle, test point etc. in and including light grade gi protection pipe 20mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate no. 3 of ssr part-i complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.note:- on testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction., inverter led light fittings batten type, 1x20w led, 230v, complete with all accessories internally per wired including lithium lon battery with charging time 8 to 10 hours and back up time up to 4 hours and connecting up with pvc insulated and sheathed, 1100 v grade, flexible, multistranded copper conductor three core cable complete all as specified and directed., led street light/ security light fitting 35 watt, 230 v, ac, outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with ip 66 protection, including provision of gi bracket made of 40mm dia, gi pipe, 1.5m long, bend to shape, complete all as specified., mcb, spn, 240 volts, 40 to 63 amps,10ka, breaking capacity, complete all as specified., mcb, spn, 240 volts, 6 to 32 amps,10ka, breaking capacity,