Get complete information related to latest Filtration Plant Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Filtration Plant Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Filtration Plant Tenders.
Tender For supply and delivery of ferric alum for maintenance of 46 m.l.d filtrationplant at gangireddula dibba hill top area, gunadala in 3rd division. 1st call general funds
Tender For supply of either capsule - either capsule , cutting wheel fourteen inch , nails , plywood for seat repair , rubber mat for bty charging shop , welding rod , cotton waste , anabond tube , araldite , hussein cloth , cloth dasooti yellow , floor mat for dust proof works stn tcm sec , flux for gas welding , hose intel for fuel filtration , hose outlet for fuel filtration , filter for fuel filtration , water separator for filtrationplant , fevicol
Tender For e-enquiry: work of water supply arrangement & ro plant operation at 400 kv rs premises such as staff colony, 400kv control room, rest house, maintenance work water supply arrangement and operation & supply of filtered drinking water from water filtrationplant at 400kv & 220kv s/s under 400kv rs, dn, dhule.
Tender For addn/altn of building no p-02 single ors accn (att barrack) and unit trg store of mh and special repair in rep of filtrationplants and rusted pipe line at stn swimming pool and certain minor works of age b/r-iii and age e/m w/s under ge (west) jabalpur
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks., electronic balance the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. , vacuum pumpthe pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted with vacuum and filter cartridge., hot air oventhe inner chamber should be made of stainless steel and the outer chamber should be m.s powder coated. the maximum capacity of the oven should be 100 ml or more. the operational temperature should be between ambient to 250 oc or more with a temperature accuracy of 1o c. pid based digital temperature control., double distillation unitthe unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil baththe oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240 oc (0.1 oc increment) with a temperature stability of 1oc., water baththe water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars. , ph conductivity meter operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range should be in between 0.00 to 29.99 s/cm, uv cabinet operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometerapplication: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca2+ :0-99.9 ppmli2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required for local calibration and routine maintenance service and
Tender For corrigendum : e-tender for supply of various medical equipment of physiology department of govt. medical college haridwar - experimental physiology -demonstration set , electric time markers 100/sec, tuning fork time marker 100/sec., spirit lamp, marys tambour, demonstrations eye piece, double demonstration eye piece, stage incubator, perimeter pristely smith s/lp .984 b & t, haemoglobinometer, sahlis or hellige (with space), haemocytometers, sphygmomanometer digital, stethoscopes, stethoscopes, demonstration with mutipleear pieces, polygraphs, venous pressure apparatus, spirometer, ordinary, gas analysis apparatus, haldanes students type, van slykes apparatus manometric, gas analyser automatic for co2, o2,n2, douglas bag complete, basal metabolism apparatus, erogographmosses, clinical digital thermometer, compass aesthesiometer, thermo esthesiometer, algometer, apparatus for passive movement, knee hammer, stethograph, bicycle ergometer, olfactometer, ophthalmoscope, schematic eye, phakoscope, perimeter with charts (listers), colour perception lantern edridge green, maddox rod, newtons colour wheel, tuning forks to test hearing 32-10,000 cps(sets), dynamometer, otoscope (47), sterilizer electric, instrument trolley, stop watches, centrifuge, high speed with tachometer, colorimeter photo-electric, ph meter, oxygen cylinder with trolley, co2 cylinder with trolley, electronic stimulator, water distillation still, all glass distillation apparatus double stage, voltage stabilizer, weighing machine, height measuring machine, digital student physiograph, thermometer, ishihara colour vision chart, snellen chart, near vision jaegar